DS230 and DS240 Safety motion monitor
SIL3/PLe motion monitor for SinCos and incremental encoders
SIL3/PLe motion monitor for SinCos and incremental encoders
Safety relays monitor safety functions such as emergency stops, safety gates and light curtains and safely stop the machine when a fault is detected. SCN supplies safety relays from Wieland Electric, including the SNZ4052K, SNE4004K, SNO4003K, SNO4062K and SNO4063K, as well as the SAMOS modular safety controller for machines with several safety functions. They are used in emergency stop circuits, safety gate and door monitoring, light curtains, two-hand control and general machine safety. Our engineers help you choose the right safety function, number of safety outputs, supply voltage and reset mode for your application.

SIL3/PLe motion monitor for SinCos and incremental encoders
SIL3/PLe motion monitor for SinCos and incremental encoders

SIL3/PLe motion monitor, incremental input up to 500 kHz
SIL3/PLe motion monitor, incremental input up to 500 kHz

Redundant motion monitor, 2 encoders, 4 relays
Redundant motion monitor, 2 encoders, 4 relays

Safety relay, two safety outputs, PL e, DIN rail
Safety relay, two safety outputs, PL e, DIN rail

Safety relay, automatic reset, 3 NO, 8 A
Safety relay, automatic reset, 3 NO, 8 A

Safety relay, automatic reset, 4 NO, 8 A
Safety relay, automatic reset, 4 NO, 8 A

Safety relay, monitored reset, 3 NO, 8 A
Safety relay, monitored reset, 3 NO, 8 A

Output expansion relay, 2 CO contacts, 24 VDC
Output expansion relay, 2 CO contacts, 24 VDC

Safety relay output expansion, 4 NO enables, 3 NC signals
Safety relay output expansion, 4 NO enables, 3 NC signals

Contact expansion relay, 2x2 NO, 24 VDC
Contact expansion relay, 2×2 NO, 24 VDC

Safety relay, 1-channel, 2 NO contacts, 22.5 mm
Safety relay, 1-channel, 2 NO contacts, 22.5 mm

Safety relay base unit, 1-channel, 3 enables, 1 signal
Safety relay base unit, 1-channel, 3 enables, 1 signal

Safety relay, 1-/2-channel, 2 NO, 1 NC signal
Safety relay, 1-/2-channel, 2 NO, 1 NC signal

Safety relay, 1-/2-channel, 3 NO, monitored reset
Safety relay, 1-/2-channel, 3 NO, monitored reset

Safety relay, 2-channel, 3 NO, synchronous timing
Safety relay, 2-channel, 3 NO, synchronous timing

Standstill monitor, 4 safe outputs, 24 VDC
Standstill monitor, 4 safe outputs, 24 VDC

Time-delay safety relay, 2+1 NO, stop category 1
Time-delay safety relay, 2+1 NO, stop category 1

Time-delay safety relay, 2+2 NO, up to 300 s
Time-delay safety relay, 2+2 NO, up to 300 s

Time-delay safety relay, 3+3 NO, up to 300 s
Time-delay safety relay, 3+3 NO, up to 300 s

Time-delay safety relay, retriggerable, 2+2 NO
Time-delay safety relay, retriggerable, 2+2 NO

2-channel safety relay with synchronous time monitoring
2-channel safety relay with synchronous time monitoring

Compact safety relay, 3 safety contacts, up to SIL3/PLe
Compact safety relay, 3 safety contacts, up to SIL3/PLe

Standstill monitor, sensorless, 2 NO, 24 VDC
Standstill monitor, sensorless, 2 NO, 24 VDC
A safety relay monitors a safety function – an emergency stop button, a safety gate, a light curtain or a two-hand control – and switches off the machine's power safely when the function is triggered or when it detects a fault in its own circuit. It uses redundant, force-guided contacts and checks itself every time it switches, so a welded contact or a short circuit cannot go unnoticed. SCN supplies safety relays from Wieland Electric and safety motion monitors from Motrona.
The Wieland range includes SNO safety relays for emergency stop and guard monitoring, SNA safety relays, SNV time-delay safety relays for stop category 1, SNE contact expansion modules, the SNZ 4052K two-hand control relay and SNS and SVM standstill monitors. Most are 22.5 mm wide DIN-rail units for 24 VDC, 24 VAC or 115–230 VAC. Motrona DS230 to DS260 monitor speed and standstill. When a machine has many safety functions, a programmable safety PLC is often simpler; standard controllers are under PLC systems.
How to choose: start with the required performance level or SIL from the risk assessment, then the type of function: emergency stop, door, light curtain, two-hand control or standstill. Then choose the number of safety and auxiliary contacts, stop category 0 or 1 and the supply voltage.
A safety relay works with two independent channels and force-guided relay contacts. Both input channels, for example the two contacts of an emergency stop, must be closed before the outputs can switch on, and the relay checks at every cycle that its own contacts have really opened. A fault such as a welded contact or a cross-circuit keeps the outputs off until it is fixed.
Typically, the supply goes to A1/A2, the two channels of the emergency stop or door switch to the safety inputs, the reset button and the NC feedback contacts of the contactors to the start circuit, and the contactors are switched through the safety outputs, often 13–14 and 23–24. Terminal names differ between models, so always follow the wiring diagram in the data sheet.
With dual-channel wiring and monitored contactors, many safety relays reach PL e and category 4 to EN ISO 13849-1, or SIL 3 to IEC 62061. The level actually achieved depends on the whole chain – sensor, relay and actuator – and must be calculated, for example with SISTEMA. Several models in the range are rated PL e and SIL 3.
A safety relay is used to stop a machine safely when a person could be at risk. Typical tasks are emergency stop circuits, interlocked guard doors, light curtains and safety mats, two-hand controls on presses, and standstill monitoring before a guard may be opened. Time-delay versions such as the Wieland SNV let drives brake in a controlled way before the power is removed.
Not sure which model you need?
Get help choosingIf you have questions about our products the AI-assistant can help guide you to what you are searching for.