Safety relays

Safety relays monitor safety functions such as emergency stops, safety gates and light curtains and safely stop the machine when a fault is detected. SCN supplies safety relays from Wieland Electric, including the SNZ4052K, SNE4004K, SNO4003K, SNO4062K and SNO4063K, as well as the SAMOS modular safety controller for machines with several safety functions. They are used in emergency stop circuits, safety gate and door monitoring, light curtains, two-hand control and general machine safety. Our engineers help you choose the right safety function, number of safety outputs, supply voltage and reset mode for your application.

Solution areas

Product categories

Acceleration

Accuracy (°)

Accuracy (%)

Approvals

Auxiliary contact

Built-in I/O

Capacity

Circuits

Coil Voltage

Communication Interface

Switching output

Contact config

Mechanical cycles

Continuous current

Control voltage DC

Control voltage AC

CPU performance

Data logging

DIN-rail

Electrical connection

Number of poles

Coding

Connector design

Cable jacket

Expansion slots

Fieldbus/Interface

Flange size

Function

Housing

I/O slave module

IP Classification

Load Cell Type

Material

Material in contact with medium

Max current DC

Max current AC

Max operating speed

Max system voltage DC

Max system voltage AC

Measuring range (mm)

Measuring range (bar)

Measuring range (kg)

Measuring range (°C)

Measuring range (°)

Torque

Power (kW)

Digital inputs

Digital outputs

Analog inputs

Analog outputs

Measuring range (l/min)

Measuring range (kHz)

Measuring technology

Measured variable

Memory

Modules

Mounting

Nominal diameter

Number of ports

Operating system

Outer Diameter

Output Voltage

Output current

Efficiency

Phase

Photocell type

Positions

Pressure type

Pressure limit PSI

Process connection

Probe length

RAID

Rated power

Remote Access

Resolution Multiturn

Resolution Singleturn

Screen size

Shaft Diameter

Storage

Stroke length

Supply voltage DC

Supply voltage AC

Temperature range

Form Factor

Touch

Type of Switch

Voltage

dB(A)

Brands

Safety relays – monitoring emergency stops, guards and two-hand controls up to PL e

A safety relay monitors a safety function – an emergency stop button, a safety gate, a light curtain or a two-hand control – and switches off the machine's power safely when the function is triggered or when it detects a fault in its own circuit. It uses redundant, force-guided contacts and checks itself every time it switches, so a welded contact or a short circuit cannot go unnoticed. SCN supplies safety relays from Wieland Electric and safety motion monitors from Motrona.

The Wieland range includes SNO safety relays for emergency stop and guard monitoring, SNA safety relays, SNV time-delay safety relays for stop category 1, SNE contact expansion modules, the SNZ 4052K two-hand control relay and SNS and SVM standstill monitors. Most are 22.5 mm wide DIN-rail units for 24 VDC, 24 VAC or 115–230 VAC. Motrona DS230 to DS260 monitor speed and standstill. When a machine has many safety functions, a programmable safety PLC is often simpler; standard controllers are under PLC systems.

How to choose: start with the required performance level or SIL from the risk assessment, then the type of function: emergency stop, door, light curtain, two-hand control or standstill. Then choose the number of safety and auxiliary contacts, stop category 0 or 1 and the supply voltage.

Frequently asked questions

How does a safety relay work?

A safety relay works with two independent channels and force-guided relay contacts. Both input channels, for example the two contacts of an emergency stop, must be closed before the outputs can switch on, and the relay checks at every cycle that its own contacts have really opened. A fault such as a welded contact or a cross-circuit keeps the outputs off until it is fixed.

How do you wire a safety relay?

Typically, the supply goes to A1/A2, the two channels of the emergency stop or door switch to the safety inputs, the reset button and the NC feedback contacts of the contactors to the start circuit, and the contactors are switched through the safety outputs, often 13–14 and 23–24. Terminal names differ between models, so always follow the wiring diagram in the data sheet.

Which performance level can a safety relay reach?

With dual-channel wiring and monitored contactors, many safety relays reach PL e and category 4 to EN ISO 13849-1, or SIL 3 to IEC 62061. The level actually achieved depends on the whole chain – sensor, relay and actuator – and must be calculated, for example with SISTEMA. Several models in the range are rated PL e and SIL 3.

What is a safety relay used for?

A safety relay is used to stop a machine safely when a person could be at risk. Typical tasks are emergency stop circuits, interlocked guard doors, light curtains and safety mats, two-hand controls on presses, and standstill monitoring before a guard may be opened. Time-delay versions such as the Wieland SNV let drives brake in a controlled way before the power is removed.

Not sure which model you need?

Get help choosing