DRH-120 Power supply 120W Single Output High Input Voltage
Features. See datashee
Features. See datashee

Features. See datashee
Features. See datashee

Features – Battery controller for DIN Rail UPS system. – Parallel connection t
Features – Battery controller for DIN Rail UPS system. – Parallel connection to DC BUS. – Suitable for 24V system up to 20A (allows battery sizes from 4Ah to 135Ah). – Installed on DIN Rail TS35 / 7.5 or 15. – Built-in battery test function. – Battery polarity protection. – Relay contact signal output and…

Features – Battery controller for DIN Rail UPS system. – Parallel connection t
Features – Battery controller for DIN Rail UPS system. – Parallel connection to DC BUS. – Suitable for 24V system up to 40A (allows battery sizes from 4Ah to 135Ah). – Installed on DIN Rail TS35 / 7.5 or 15. – Built-in battery test function. – Battery polarity protection. – Relay contact signal output and…

NDR series is one economical slim DIN rail power supply series from Mean Well, adapt to be
NDR series is one economical slim DIN rail power supply series from Mean Well, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2,…

Features – High efficiency 91% and low power dissipation – Built-in active PFC
Features – High efficiency 91% and low power dissipation – Built-in active PFC function, PF>0.93 – Protections: Short circuit / Overload / Over voltage / Over temperature – Cooling by free air convection – Can be installed on DIN rail TS-35/7.5 or 15 – UL 508 (industrial control equipment) approved – EN61000-6-2(EN50082-2) industrial immunity level…

Features – High efficiency 94% and low power dissipation – Built-in active PFC
Features – High efficiency 94% and low power dissipation – Built-in active PFC function, PF>0.93 – Protections: Short circuit / Overload / Over voltage / Over temperature – Cooling by free air convection – Can be installed on DIN rail TS-35/7.5 or 15 – UL 508 (industrial control equipment) approved – EN61000-6-2(EN50082-2) industrial immunity level…

Features – High efficiency 94% and low power dissipation – 150% peak load capa
Features – High efficiency 94% and low power dissipation – 150% peak load capability – Built-in active PFC function, PF>0.94 – Protections: Short circuit / Overload / Over voltage / Over temperature – Cooling by free air convection – Built-in constant current limiting circuit – Can be installed on DIN rail TS-35/7.5 or 15 –…

Features – Current sharing up to 3840W(7+1) – High efficiency 94% and low powe
Features – Current sharing up to 3840W(7+1) – High efficiency 94% and low power dissipation – 150% peak load capability – Built-in active PFC function, PF>0.94 – Protections: Short circuit / Overload / Over voltage / Over temperature – Cooling by free air convection – Built-in constant current limiting circuit – Can be installed on…

Features – High efficiency 90% and low power dissipation – 150% peak load capa
Features – High efficiency 90% and low power dissipation – 150% peak load capability – Protections: Short circuit / Overload / Over voltage / Over temperature – Cooling by free air convection – Can be installed on DIN rail TS-35/7.5 or 15 – UL 508 (industrial control equipment) approved – EN61000-6-2(EN50082-2) industrial immunity level –…

Features Single phase 180~264VAC input range 110mm slim design 94% high efficiency 130% pe
Features Single phase 180~264VAC input range 110mm slim design 94% high efficiency 130% peak load capability for 3 seconds Built-in active PFC function Built-in parallel function, current sharing up to 4 units Protection: Short circuit / Overload(C.C. mode, shut down after 3 seconds) / Over voltage / Over temperature Fan-less design, cooling by free air…