For rugged environments, off-road and tracked vehicles.
Current trip setting range ±20-600 Amp.
Automatic Over Current Disconnect: When the trip limit is exceeded the contacts will open and the Trip indicator line will go low. The TRIP pin is an open drain. After a trip, V-control needs to be brought low to reset the contactor.
The current sense range is from -600 to +600 Amps (0V to 5V).
The contactor’s operating coil, and if an auxilary contact is selected too, it needs to be connected with Deutch connector 0857.
Need to be ordered separately and more information is available here https://scn.no/no-components/power-contractors/accessories/0857
| Added function | Over current |
|---|---|
| Auxilary contact | Normally open (NO) |
| Coil Voltage | 12VDC, 24VDC |
| Contact config | Normally open (NO) |
| Continuous current | 350A, 600A |
| Max current | 3000A, 5000A |
| Mechanical cycles | 300000 |
| Mounting | Chassis |
| Sector | Defence, Vehicle Solutions |
Tom Schönberg hjelper deg gjerne med å navigere gjennom produktutvalget vårt.
Tom Schönberg hjelper deg gjerne med å navigere gjennom produktutvalget vårt.
Stefan Rosenback hjelper deg gjerne med å navigere gjennom produktutvalget vårt.
Roland Isaksson hjelper deg gjerne med å navigere gjennom produktutvalget vårt.
Har du spørsmål om produktene våre, kan AI-assistenten veilede deg til det du leter etter.