For rugged environments, off-road and tracked vehicles.
When the trip limit is exceeded the contacts will open and the Trip indicator line will go low. The TRIP pin is an open drain. After a trip, V-control needs to be brought low to reset the contactor. Current trip setting range ±20-600 Amp.
Current Sense: Indicates the current through the main contacts (A2 and A1).
The current sense range is from -600 to +600 Amps (0V to 5V).
The contactor’s operating coil, and if an auxilary contact is selected too, it needs to be connected with Deutch connector 0857.
Need to be ordered separately and more information is available here https://scn.no/no-components/power-contractors/accessories/0857
| Added function | Current sensing |
|---|---|
| Auxilary contact | Normally open (NO) |
| Coil Voltage | 12VDC, 24VDC |
| Contact config | Normally open (NO) |
| Continuous current | 350A, 600A |
| Max current | 3000A, 5000A |
| Mechanical cycles | 300000 |
| Mounting | Chassis |
| Sector | Defence, Vehicle Solutions |