Flow sensors

Solution areas

Product categories

Brands

  • 200 Flow sensor

    200 Flow sensor

    The vortex flow sensor type 200 is based on the Kármán vortex street. You can choose bet

    The vortex flow sensor type 200 is based on the Kármán vortex street. You can choose between various versions as integrated temperature measurement. This flow sensor without moving parts is insensitive to pollution and persuade by very few loss of pressure and a very high accuracy.

  • 210 Flow sensor

    210 Flow sensor

    The flow sensor type 210 is based on the Kármán vortex trail principle. In comparison to

    The flow sensor type 210 is based on the Kármán vortex trail principle. In comparison to the OEM flow sensor (type 200), the type 210 is available with enhanced power supply and output signals and is available with and without temperature measurement. The flow sensor type 210 is based on the Kármán vortex trail principle….

  • 230 Flow sensor

    230 Flow sensor

    The flow sensor type 230 is based on the Kármán vortex trail. You can choose between var

    The flow sensor type 230 is based on the Kármán vortex trail. You can choose between various versions as integrated temperature measurement. The type 230 has a rugged construction of red brass. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy.

  • 235 Flow sensor

    235 Flow sensor

    The type 235 is based on the type 200 but incorporates a brass housing. The flow sensor ty

    The type 235 is based on the type 200 but incorporates a brass housing. The flow sensor type 235 is based on the Kármán vortex trail. You can choose between various versions as integrated temperature measurement. With no moving parts the flow sensor is not sensitive to debris, has marginal pressure loss and high accuracy.

  • 236 Flow sensor

    236 Flow sensor

    The type 236 is based on the type 210 but incorporates a brass housing. The Vortex Sensor

    The type 236 is based on the type 210 but incorporates a brass housing. The Vortex Sensor type 236 has a rugged construction of brass connection. This flow sensor is available with a larger variety concerning power supply and outputs.You can choose between various versions as integrated temperature measurement. With no moving parts the flow…

  • 240 Flow sensor

    240 Flow sensor

    The flow sensor Type 240 is based on the VORTEX principle and provides reliable measuremen

    The flow sensor Type 240 is based on the VORTEX principle and provides reliable measurement results of liquids with different specific viscosities – from cryogenic protection agents to drinking water. It operates without moving parts, which ensures a long service life and high accuracy.

  • FFAF009 UniFlow sensor

    FFAF009 UniFlow sensor

    Wenglor UniFlow sensors measure the flow rate of oily media in closed piping systems. UniF

    Wenglor UniFlow sensors measure the flow rate of oily media in closed piping systems. UniFlow sensors are very easy to operate thanks to the integrated display. The highly visible switching status enables the rapid localization of affected sensors for maintenance processes.

  • FFXF001 UniFlow sensor

    FFXF001 UniFlow sensor

    Wenglor UniFlow sensors measure the flow rate of oily media in closed piping systems. UniF

    Wenglor UniFlow sensors measure the flow rate of oily media in closed piping systems. UniFlow sensors are very easy to operate thanks to the integrated display. The highly visible switching status enables the rapid localization of affected sensors for maintenance processes.

  • Flow sensor with IO-Link, FXFF003 WeFlux2

    Flow sensor with IO-Link, FXFF003 WeFlux2

    weFlux² flow sensors simultaneously measure flow velocity and the temperature of aqueous

    weFlux² flow sensors simultaneously measure flow velocity and the temperature of aqueous liquids regardless of position and flow direction. The advantage of this is that the number of measuring points and the diversity of sensor variants are cut in half, providing the greatest possible flexibility when installing in closed piping systems. Depending on application requirements,…

  • Flow Sensor, FXFF001

    Flow Sensor, FXFF001

    weFlux² flow sensors simultaneously measure flow velocity and the temperature of aqueous

    weFlux² flow sensors simultaneously measure flow velocity and the temperature of aqueous liquids regardless of position and flow direction. The advantage: The number of measuring points and the diversity of sensor variants are cut in half, ensuring the greatest possible flexibility when installing in closed piping systems. Either 2 switching outputs or 1 switching output…

  • V10F Magnetically operated flow switch

    V10F Magnetically operated flow switch

    Flow Switch V10F Series For inline installations, these small units offer a convenient sol

    Flow Switch V10F Series For inline installations, these small units offer a convenient solution for flow monitoring. With a variety of available fittings, V10F installation along straight runs of pipe or hose is simple and straightforward. The optional integrated check valve feature is a significant advantage in some applications. Available in a variety of materials…

  • V121F Larger size vane operated flow switch

    V121F Larger size vane operated flow switch

    Flow Switch V121F Series For high flow switching applications up to 20 GPM, this design of

    Flow Switch V121F Series For high flow switching applications up to 20 GPM, this design offers the same proven advantages of the V121F series but features larger fittings for reduced pressure drop. The nonmagnetic switching principle produces resistance to both dirty media and external electromagnetic equipment. The inline design is easily integrated into most plumbing…

  • V21F Vane operated flow switch

    V21F Vane operated flow switch

    Flow Switch V21F Series This nonmagnetic design offers excellent performance in environmen

    Flow Switch V21F Series This nonmagnetic design offers excellent performance in environments which would normally prevent the use of a flow switch. The lack of sliding or rotating parts allows the use of contaminated fluids, while the lack of magnets allows solenoids to be mounted nearby. The electrical switch is hermetically sealed in a pressure…

  • V221F Vane operated flow switch

    V221F Vane operated flow switch

    Available settings: 10 to 25 GPM V-F Series Flow Switch The V-F vane actuated flow switch

    Available settings: 10 to 25 GPM V-F Series Flow Switch The V-F vane actuated flow switch series is among the most commonly selected flow devices for aerospace applications in the Precision Sensors product line. Bellows technology provides a hermetic seal to a lever style vane which is displaced by the moving fluid. The vane design…

  • V22F Vane operated flow switch

    V22F Vane operated flow switch

    Flow Switch V22F Series With a range that extends up to 10 GPM, the V22F covers the most c

    Flow Switch V22F Series With a range that extends up to 10 GPM, the V22F covers the most common flow ranges in aerospace and military applications. The nonmagnetic design principle eliminates concerns about interface from external magnetic fields. The use of a thin-edge metering disc promotes set point stability over wide range fluid viscosity changes…

  • V9F Magnetically operated flow switch

    V9F Magnetically operated flow switch

    Flow Switch V9F Series These specifically engineered units are for use in tight spaces whe

    Flow Switch V9F Series These specifically engineered units are for use in tight spaces where outlet flow is directed at 90° relative to the inlet. Using a V9F in place of an elbow results in a reduction of plumbing and weight savings as compared to an inline design. The hermetically sealed switch contacts are isolated…