{"id":1013957,"date":"2025-01-01T00:00:00","date_gmt":"2025-01-01T00:00:00","guid":{"rendered":"http:\/\/&#038;p=1013957"},"modified":"2026-03-20T01:45:54","modified_gmt":"2026-03-20T01:45:54","slug":"rer02-sv","status":"publish","type":"product","link":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/","title":{"rendered":"RER02 High Voltage Contactor 40A up to 1000VDC"},"content":{"rendered":"<p>SPECIFICATIONS<\/p>\n<p>Contact Arrangement Form X, SPST NO<br \/>\nMax Switching Voltage 1000 VDC<br \/>\nContinuous Current (15mm2 conductor) 40A<br \/>\nOverload Current 30 seconds 80A<br \/>\n1 hour 30A<br \/>\nMax Break \u2013 30A @ 450V 5 cycles<br \/>\nMax Short Circuit Current -0.5 second 200 A<br \/>\nMin Insulation Resistance 1,000 Mohm @ 500VDC<br \/>\nContact Voltage Drop (Max) 50mV @ 10A<br \/>\nOperate Time (Max, incl bounce) 30ms<br \/>\nRelease Time (Max) 10ms<br \/>\nShock &#8211; Functional, 1\/2 Sine, 11ms 20G<br \/>\nShock \u2013 Destructive, 1\/2 Sine, 11ms 50G<br \/>\nOperating Temperature -40\u02daC to 85\u02daC<br \/>\nIngress Protection IP67<br \/>\nMechanical life 200,000 cycles<br \/>\nNominal Voltage 12 VDC or 24 VDC<br \/>\nCoil Power at Nominal Voltage 3W<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SPECIFICATIONS Contact Arrangement Form X, SPST NO Max Switching Voltage 1000 VDC Continuous Current (15mm2 conductor) 40A Overload Current 30 seconds 80A 1 hour 30A Max Break \u2013 30A @ 450V 5 cycles Max Short Circuit Current -0.5 second 200 A Min Insulation Resistance 1,000 Mohm @ 500VDC Contact Voltage Drop (Max) 50mV @ 10A&#8230;<\/p>\n","protected":false},"featured_media":8030816,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":""},"product_brand":[943],"product_cat":[10630,9067,10656,10759],"product_tag":[],"product_facet":[10773],"class_list":["post-1013957","product","type-product","status-publish","has-post-thumbnail","product_brand-rincon-power","product_cat-components","product_cat-pcb-mount","product_cat-power-contactors","product_cat-products","product_facet-facet-components","first","instock","downloadable","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>RER02 High Voltage Contactor 40A up to 1000VDC | SCN<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RER02 High Voltage Contactor 40A up to 1000VDC | SCN\" \/>\n<meta property=\"og:description\" content=\"SPECIFICATIONS Contact Arrangement Form X, SPST NO Max Switching Voltage 1000 VDC Continuous Current (15mm2 conductor) 40A Overload Current 30 seconds 80A 1 hour 30A Max Break \u2013 30A @ 450V 5 cycles Max Short Circuit Current -0.5 second 200 A Min Insulation Resistance 1,000 Mohm @ 500VDC Contact Voltage Drop (Max) 50mV @ 10A...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-20T01:45:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/RER02.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"338\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/\",\"name\":\"RER02 High Voltage Contactor 40A up to 1000VDC | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/RER02.png\",\"datePublished\":\"2025-01-01T00:00:00+00:00\",\"dateModified\":\"2026-03-20T01:45:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/RER02.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/RER02.png\",\"width\":500,\"height\":338},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/produkt\\\/rer02-sv\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/sv\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produkter\",\"item\":\"https:\\\/\\\/scn.eu\\\/sv\\\/butik\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"RER02 High Voltage Contactor 40A up to 1000VDC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/sv\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/sv\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/#organization\",\"name\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/sv\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"SCN\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/sv\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RER02 High Voltage Contactor 40A up to 1000VDC | SCN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/","og_locale":"sv_SE","og_type":"article","og_title":"RER02 High Voltage Contactor 40A up to 1000VDC | SCN","og_description":"SPECIFICATIONS Contact Arrangement Form X, SPST NO Max Switching Voltage 1000 VDC Continuous Current (15mm2 conductor) 40A Overload Current 30 seconds 80A 1 hour 30A Max Break \u2013 30A @ 450V 5 cycles Max Short Circuit Current -0.5 second 200 A Min Insulation Resistance 1,000 Mohm @ 500VDC Contact Voltage Drop (Max) 50mV @ 10A...","og_url":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/","og_site_name":"SCN","article_modified_time":"2026-03-20T01:45:54+00:00","og_image":[{"width":500,"height":338,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/RER02.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"1 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/","url":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/","name":"RER02 High Voltage Contactor 40A up to 1000VDC | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/sv\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/RER02.png","datePublished":"2025-01-01T00:00:00+00:00","dateModified":"2026-03-20T01:45:54+00:00","breadcrumb":{"@id":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/RER02.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/RER02.png","width":500,"height":338},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/sv\/produkt\/rer02-sv\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/sv\/"},{"@type":"ListItem","position":2,"name":"Produkter","item":"https:\/\/scn.eu\/sv\/butik\/"},{"@type":"ListItem","position":3,"name":"RER02 High Voltage Contactor 40A up to 1000VDC"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/sv\/#website","url":"https:\/\/scn.eu\/sv\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/sv\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/sv\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/scn.eu\/sv\/#organization","name":"SCN","url":"https:\/\/scn.eu\/sv\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/scn.eu\/sv\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"SCN"},"image":{"@id":"https:\/\/scn.eu\/sv\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product\/1013957","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/comments?post=1013957"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product\/1013957\/revisions"}],"predecessor-version":[{"id":8030818,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product\/1013957\/revisions\/8030818"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/media\/8030816"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/media?parent=1013957"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product_brand?post=1013957"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product_cat?post=1013957"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product_tag?post=1013957"},{"taxonomy":"product_facet","embeddable":true,"href":"https:\/\/scn.eu\/sv\/wp-json\/wp\/v2\/product_facet?post=1013957"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}