SGT9834300 Halvledarrelä 35A
SGT9834300 Strömfördelning: 3x35A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Sty
SGT9834300 Strömfördelning: 3x35A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Styrspänning: 4-30VDC

SGT9834300 Strömfördelning: 3x35A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Sty
SGT9834300 Strömfördelning: 3x35A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Styrspänning: 4-30VDC

SGT9854300 Strömfördelning: 3x50A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Sty
SGT9854300 Strömfördelning: 3x50A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Styrspänning: 4-30VDC

SGT9854320 Strömfördelning: 3x50A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Sty
SGT9854320 Strömfördelning: 3x50A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Styrspänning: 4-30VDC

SGT9874300 Strömfördelning: 3x75A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Sty
SGT9874300 Strömfördelning: 3x75A Kopplingsspänning: 24-660VAC Toppspänning: 1600V Styrspänning: 4-30VDC

Trefas nollgenomgångs halvledarrelä speciellt designat för de flesta typer av belastnin
Trefas nollgenomgångs halvledarrelä speciellt designat för de flesta typer av belastningar (AC-1 och AC-3). Överspänningsskydd vid ingång (transil) och utgång (RC + VDR). Rygg mot rygg tyristorer på utgång med TMS²-teknik för en lång förväntad livslängd: 24 till 520VAC 3x125A. Ström begränsad av kontakterna vid 41A. Teknik för direkt kopparbindning (DCB). Stort kontrollområde: 4-30VDC med…

Trefas nollgenomgångs halvledarrelä speciellt designat för AC-1 resistiva belastningar.
Trefas nollgenomgångs halvledarrelä speciellt designat för AC-1 resistiva belastningar. Överspänningsskydd vid ingång (transil) och utgång (TVS). Rygg mot rygg tyristorer på utgång med TMS²-teknik för en lång förväntad livslängd: 24 till 660VAC max. 3x60A. Ström begränsad av kontakterna vid 41A. Teknik för direkt kopparbindning (DCB). Stort kontrollområde: 4-30VDC med ingångsströmbegränsare. Grön LED-visualisering på ingången. Dubbla…

Hermetiskt tät och klassad till 175°C med minskad risk för brand eller härdsmälta und
Hermetiskt tät och klassad till 175°C med minskad risk för brand eller härdsmälta under överströmsförhållanden. Återfylld med gas (främst väte) för att effektivt hämma oxidation, vilket resulterar i en låg och stabil kontaktresistans. Isolationsresistansen ligger på 1000MΩ (1000Vdc), medan den dielektriska styrkan mellan spolen och kontakterna når 4,0kV. Kontinuerlig ström på 150A vid 85°C, Följer…

Hermetiskt tät och klassad till 175°C med minimal risk för brand eller härdsmälta und
Hermetiskt tät och klassad till 175°C med minimal risk för brand eller härdsmälta under överströmsförhållanden. Återfylld med gas (främst väte) för att effektivt hämma oxidation, vilket resulterar i en låg och stabil kontaktresistans. Isolationsresistansen ligger på 1000MΩ (1000Vdc), medan den dielektriska styrkan mellan spolen och kontakterna når 4,0kV. Kontinuerlig ström på 250A vid 85°C, Följer…

Hermetiskt tät och klassad till 175°C med minimal risk för brand eller härdsmälta und
Hermetiskt tät och klassad till 175°C med minimal risk för brand eller härdsmälta under överströmsförhållanden. Återfylld med gas (främst väte) för att effektivt hämma oxidation, vilket resulterar i en låg och stabil kontaktresistans. Kontinuerlig ström på 400A vid 85°C, Klararar hög kortslutningsström 10kA under 5ms. Följer IEC 60664-1 och RoHS-standarder.

PRINCIPAL TECHNICAL CHARACTERISTICS • Monobloc design in polycarbonate resin • Fire an
PRINCIPAL TECHNICAL CHARACTERISTICS • Monobloc design in polycarbonate resin • Fire and smoke specification NFF 16-101 / NFF 16-102 • Railway standard: IEC60571, EN50155 • Operating temperature: -25°C to +70°C • Weight 113 g ±5% (470 / D470 / THL) • Mounting: DIN Rail EN50022 • Suitable for relay with B, D and H mounting…

3 x 25A/280VAC-utgång 3,5-10 VDC-styrning eller 10-30 VDC-styrning
3 x 25A/280VAC-utgång 3,5-10 VDC-styrning eller 10-30 VDC-styrning

SIB942360 Strömfördelning: 2x30A Kopplingsspänning: 12-280VAC Styrspänning: 12-24VDC
SIB942360 Strömfördelning: 2x30A Kopplingsspänning: 12-280VAC Styrspänning: 12-24VDC

SILD867170 Utgångsspänning: 150-510VAC Tyristorklassning: 35A V toppvärde (V): 1200V St
SILD867170 Utgångsspänning: 150-510VAC Tyristorklassning: 35A V toppvärde (V): 1200V Styrspänning: 3,5-32VDC Diagnostik: 30VDC 100mA

MATERIAL: SILIKON DUROMETER 20A FÄRG: SVART Mer information i databladet/ritningen nedan.
MATERIAL: SILIKON DUROMETER 20A FÄRG: SVART Mer information i databladet/ritningen nedan.

The SIM100MLP is the first high-voltage isolation monitoring device for EV/HEVs capable of
The SIM100MLP is the first high-voltage isolation monitoring device for EV/HEVs capable of operating correctly even when the battery is active, and experiencing large voltage variations, no variations, or even if the battery is not connected. The SIM100MLP continuously monitors the isolation resistance between a vehicle’s IT (Isolated Terra) power system and chassis for deterioration…

The SIM100MOD is the first high-voltage isolation monitoring device for EV/HEVs capable of
The SIM100MOD is the first high-voltage isolation monitoring device for EV/HEVs capable of operating correctly even when the battery is active, and experiencing large voltage variations, no variations, or even if the battery is not connected. The device continuously monitors the isolation resistance between a vehicle’s IT (Isolated Terra) power system and chassis for deterioration…

The SIM200 Insulation Monitoring Device (IMD) is designed for continuous active monitoring
The SIM200 Insulation Monitoring Device (IMD) is designed for continuous active monitoring of unearthed (Isolated Terra) DC systems including charging stations, electric vehicles, and any other system with a nominal operation above 60VDC. The SIM200 is UL2231 recognized to ensure safety at the highest standards and responds to electric hazards quickly and reliably with a…

• Sortiment för kretskort för montering på en extern kylfläns. • Tyristor- och DCB
• Sortiment för kretskort för montering på en extern kylfläns. • Tyristor- och DCB-teknik (direkt kopparbindning) • 1600Vpeak modell • I2t min 800 A2s • Nollkorsande AC-utgång. • Tyristorvärde: 40A.

Sortiment för montering på kretskort, extern kylfläns måste också monteras. • Tyris
Sortiment för montering på kretskort, extern kylfläns måste också monteras. • Tyristor- och DCB-teknik (direkt kopparbindning) • Nollgenomgångs AC-utgång. • Tyristorvärde: 25A.

Sortiment för montering på kretskort, extern kylfläns måste också monteras. • Tyris
Sortiment för montering på kretskort, extern kylfläns måste också monteras. • Tyristor- och DCB-teknik (direkt kopparbindning) • Slumpmässig AC-utgång. • Tyristorvärde: 25A.

Detta sortiment av släpringar har i första hand utformats för överföring av signaler,
Detta sortiment av släpringar har i första hand utformats för överföring av signaler, men har vidareutvecklats för att även kunna användas för kraftöverföring. Fina mässingsringar används för signaler och kan pläteras med silver, guld eller rhodium när lågt kontaktmotstånd och låga ljudnivåer krävs. De bästa resultaten uppnås också när dessa ädelmetallytor används tillsammans med silvergrafitborstar….

Detta sortiment av släpringar har i första hand utformats för överföring av signaler,
Detta sortiment av släpringar har i första hand utformats för överföring av signaler, men har vidareutvecklats för att även kunna användas för kraftöverföring. Fina mässingsringar används för signaler och kan pläteras med silver, guld eller rhodium när lågt kontaktmotstånd och låga ljudnivåer krävs. De bästa resultaten uppnås också när dessa ädelmetallytor används tillsammans med silvergrafitborstar….

Släpringar för servosystem för att mäta det faktiska läget i det mekaniska systemet f
Släpringar för servosystem för att mäta det faktiska läget i det mekaniska systemet för att jämföra med styrsystemet.

Vindkraftverk kräver pålitlig överföring av kraft- och datasignaler från generatorhus
Vindkraftverk kräver pålitlig överföring av kraft- och datasignaler från generatorhuset till styrsystemet för de roterande bladen. Kostsamma driftsstopp elimineras genom att använda fiberborstar och robusta mekaniska komponenter i släpringskonstruktionen.

Släpringarna med extra lång livslängd och möjlighet till renovering för en lång och
Släpringarna med extra lång livslängd och möjlighet till renovering för en lång och säker drift. De skadebenägna komponenterna i den nya enheten har en vetenskapligt utvecklad modulär konstruktion som gör det lätt att ta isär och/eller installera dem utan att behöva demontera huset. Snabbt och bekvämt byte av interna delar bidrar också det till att…
Om du har frågor om våra produkter kan AI-assistenten hjälpa dig att hitta det du söker.