{"id":8234639,"date":"2026-10-24T17:26:47","date_gmt":"2026-10-24T17:26:47","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234639"},"modified":"2026-10-24T17:32:38","modified_gmt":"2026-10-24T17:32:38","slug":"switch-zarzadzalny-czy-niezarzadzalny","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/","title":{"rendered":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN<\/h1>\n<p class=\"g-lead\">Switch niezarz\u0105dzalny \u0142\u0105czy urz\u0105dzenia bez \u017cadnych ustawie\u0144. Switch zarz\u0105dzalny pozwala sterowa\u0107 ruchem, nadawa\u0107 mu priorytety i go monitorowa\u0107. W tym poradniku wyja\u015bniamy r\u00f3\u017cnice, wymagania przemys\u0142u i to, kiedy warto wybra\u0107 Time-Sensitive Networking (TSN).<\/p>\n<div class=\"g-short\"><b class=\"t\">Kr\u00f3tka odpowied\u017a<\/b><\/p>\n<ul>\n<li><b>Niezarz\u0105dzalny<\/b> \u2013 plug and play, bez ustawie\u0144. Wystarcza w ma\u0142ej, odizolowanej maszynie lub gnie\u017adzie produkcyjnym.<\/li>\n<li><b>Zarz\u0105dzalny<\/b> \u2013 VLAN, priorytetyzacja, IGMP snooping, redundancja i diagnostyka. Potrzebny, gdy sie\u0107 si\u0119 rozrasta lub \u0142\u0105czy z sieci\u0105 zak\u0142adow\u0105.<\/li>\n<li><b>Smart switch<\/b> \u2013 rozwi\u0105zanie po\u015brednie z kluczowymi funkcjami i prostsz\u0105 konfiguracj\u0105.<\/li>\n<li><b>Pier\u015bcie\u0144<\/b> \u2013 dzi\u0119ki protoko\u0142owi pier\u015bcieniowemu sie\u0107 odtwarza si\u0119 w ci\u0105gu milisekund po przerwaniu kabla.<\/li>\n<li><b>TSN<\/b> \u2013 gwarantowane op\u00f3\u017anienie w standardowym Ethernecie. Istotne, gdy sterowanie, wideo i IT wsp\u00f3\u0142dziel\u0105 jedn\u0105 sie\u0107.<\/li>\n<\/ul>\n<\/div>\n<h2>Na czym polega r\u00f3\u017cnica?<\/h2>\n<p>Switch przesy\u0142a ka\u017cd\u0105 ramk\u0119 Ethernet do w\u0142a\u015bciwego portu. Switch niezarz\u0105dzalny robi tylko tyle: sam uczy si\u0119 adres\u00f3w i dzia\u0142a od razu po pod\u0142\u0105czeniu. Switch zarz\u0105dzalny mo\u017cna konfigurowa\u0107 przez przegl\u0105dark\u0119, wiersz polece\u0144 lub SNMP. Mo\u017cna wtedy podzieli\u0107 sie\u0107, nada\u0107 priorytet wa\u017cnemu ruchowi, zapewni\u0107 redundancj\u0119 i widzie\u0107, co dzieje si\u0119 na ka\u017cdym porcie.<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Funkcja<\/th>\n<th>Niezarz\u0105dzalny<\/th>\n<th>Zarz\u0105dzalny<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">Ustawienia<\/td>\n<td>Brak<\/td>\n<td>WWW, wiersz polece\u0144, SNMP<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">VLAN<\/td>\n<td>Nie<\/td>\n<td>Tak, IEEE 802.1Q<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Priorytetyzacja<\/td>\n<td>Czasem sta\u0142a<\/td>\n<td>Tak, konfigurowalna<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">IGMP snooping<\/td>\n<td>Nie<\/td>\n<td>Tak<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Redundancja<\/td>\n<td>Nie<\/td>\n<td>RSTP, MRP i protoko\u0142y pier\u015bcieniowe<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Diagnostyka<\/td>\n<td>Diody LED, czasem przeka\u017anik alarmowy<\/td>\n<td>Statystyki port\u00f3w, alarmy, logi, mirroring port\u00f3w<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Bezpiecze\u0144stwo<\/td>\n<td>Brak<\/td>\n<td>Konta u\u017cytkownik\u00f3w, blokada port\u00f3w, IEEE 802.1X<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Cena<\/td>\n<td>Ni\u017csza<\/td>\n<td>Wy\u017csza<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Pomi\u0119dzy nimi s\u0105 smart switche, nazywane czasem cz\u0119\u015bciowo zarz\u0105dzalnymi. Oferuj\u0105 wybrane funkcje, takie jak VLAN, RSTP oraz obs\u0142uga PROFINET lub EtherNet\/IP, ale \u0142atwiej je skonfigurowa\u0107.<\/p>\n<h2>Funkcje, kt\u00f3re licz\u0105 si\u0119 w przemy\u015ble<\/h2>\n<h3>VLAN<\/h3>\n<p>VLAN dzieli jedn\u0105 fizyczn\u0105 sie\u0107 na kilka logicznych. Systemy sterowania, kamery i ruch biurowy mog\u0105 korzysta\u0107 z tych samych switchy, nie widz\u0105c si\u0119 nawzajem. Ogranicza to zak\u0142\u00f3cenia i poprawia bezpiecze\u0144stwo.<\/p>\n<h3>Priorytetyzacja (QoS)<\/h3>\n<p>Ruch jest oznaczany priorytetem zgodnie z IEEE 802.1p, dzi\u0119ki czemu dane I\/O maj\u0105 pierwsze\u0144stwo przed transferem plik\u00f3w i wideo, gdy \u0142\u0105cze jest mocno obci\u0105\u017cone.<\/p>\n<h3>IGMP snooping<\/h3>\n<p>Switch wysy\u0142a multicast tylko do port\u00f3w, kt\u00f3re o niego poprosi\u0142y. Ma to znaczenie w sieciach EtherNet\/IP i przy strumieniach wideo, gdzie multicast w przeciwnym razie zala\u0142by ca\u0142\u0105 sie\u0107.<\/p>\n<h3>Redundancja<\/h3>\n<p>RSTP (IEEE 802.1w) to standard dzia\u0142aj\u0105cy mi\u0119dzy r\u00f3\u017cnymi markami, ale odtworzenie sieci mo\u017ce trwa\u0107 od poni\u017cej sekundy do kilku sekund w wi\u0119kszych sieciach. Protoko\u0142y pier\u015bcieniowe, takie jak MRP (IEC 62439-2), i protoko\u0142y producent\u00f3w, takie jak Moxa Turbo Ring, przywracaj\u0105 \u0142\u0105czno\u015b\u0107 w ci\u0105gu dziesi\u0105tek do setek milisekund. HSR i PRP (IEC 62439-3) wysy\u0142aj\u0105 ruch jednocze\u015bnie dwiema drogami, zapewniaj\u0105c redundancj\u0119 bez przerw, np. w podstacjach.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-pl.webp\" alt=\"Cztery switche w pier\u015bcieniu. \u0141\u0105cze mi\u0119dzy switchem 2 i 3 jest przerwane, a zablokowane \u0142\u0105cze zapasowe mi\u0119dzy switchem 4 i 1 otwiera si\u0119, wi\u0119c ruch biegnie drug\u0105 stron\u0105\" width=\"1520\" height=\"520\" loading=\"lazy\" decoding=\"async\"><figcaption>Pier\u015bcie\u0144 czterech switchy: po przerwaniu kabla otwiera si\u0119 zablokowane \u0142\u0105cze zapasowe.<\/figcaption><\/figure>\n<h3>Diagnostyka i PoE<\/h3>\n<p>Switch zarz\u0105dzalny pokazuje stan \u0142\u0105cza, b\u0142\u0119dy i ruch na ka\u017cdym porcie oraz mo\u017ce wysy\u0142a\u0107 alarmy przez SNMP, e-mail lub wyj\u015bcie przeka\u017anikowe. PoE zasila kamery, punkty dost\u0119powe i czujniki przez kabel sieciowy: do 15,4 W na port wed\u0142ug IEEE 802.3af, 30 W wed\u0142ug 802.3at i do 90 W wed\u0142ug 802.3bt, mierz\u0105c na switchu.<\/p>\n<h2>Czego przemys\u0142 wymaga od switcha?<\/h2>\n<ul>\n<li><b>Temperatura<\/b> \u2013 switche przemys\u0142owe s\u0105 dost\u0119pne na zakres od \u221240 do 75 \u00b0C, bez wentylator\u00f3w.<\/li>\n<li><b>Monta\u017c<\/b> \u2013 szyna DIN lub \u015bciana z metalow\u0105 obudow\u0105, a dla sieci szkieletowych szafy 19-calowe.<\/li>\n<li><b>Zasilanie<\/b> \u2013 podw\u00f3jne wej\u015bcia DC, np. 12\u201348 V DC, oraz przeka\u017anik alarmowy sygnalizuj\u0105cy zanik zasilania.<\/li>\n<li><b>Z\u0142\u0105cza i szczelno\u015b\u0107<\/b> \u2013 M12 zamiast RJ45 tam, gdzie wyst\u0119puj\u0105 drgania, oraz IP67 w pojazdach i na zewn\u0105trz.<\/li>\n<li><b>Certyfikaty<\/b> \u2013 EN 50155 dla pojazd\u00f3w szynowych, IEC 61850-3 dla podstacji oraz Class I Division 2 lub ATEX strefa 2 dla stref zagro\u017conych wybuchem.<\/li>\n<\/ul>\n<h3>Jaki switch gdzie pasuje?<\/h3>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Zastosowanie<\/th>\n<th>Odpowiedni wyb\u00f3r<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Ma\u0142a maszyna z kilkoma urz\u0105dzeniami, bez sieci zak\u0142adowej<\/td>\n<td>Switch niezarz\u0105dzalny<\/td>\n<\/tr>\n<tr>\n<td>Maszyny pod\u0142\u0105czane do sieci klienta<\/td>\n<td>Switch zarz\u0105dzalny lub smart z VLAN i obs\u0142ug\u0105 PROFINET lub EtherNet\/IP<\/td>\n<\/tr>\n<tr>\n<td>Wiele urz\u0105dze\u0144 EtherNet\/IP lub strumieni wideo<\/td>\n<td>Switch zarz\u0105dzalny z IGMP snooping<\/td>\n<\/tr>\n<tr>\n<td>Proces, w kt\u00f3rym przerwanie kabla nie mo\u017ce zatrzyma\u0107 produkcji<\/td>\n<td>Switch zarz\u0105dzalny z protoko\u0142em pier\u015bcieniowym lub MRP<\/td>\n<\/tr>\n<tr>\n<td>Zasilanie kamer i punkt\u00f3w dost\u0119powych w tunelach, na parkingach lub w portach<\/td>\n<td>Switch z PoE<\/td>\n<\/tr>\n<tr>\n<td>Sieci w poci\u0105gach i tramwajach<\/td>\n<td>Switch M12 zgodny z EN 50155<\/td>\n<\/tr>\n<tr>\n<td>Podstacje i rozdzielnie<\/td>\n<td>Switch zgodny z IEC 61850-3, cz\u0119sto z PRP lub HSR<\/td>\n<\/tr>\n<tr>\n<td>Pojazdy, statki lub systemy obronne<\/td>\n<td>Szczelny switch IP67 lub switch VPX<\/td>\n<\/tr>\n<tr>\n<td>Po\u0142\u0105czenie sterowania, wideo i IT z gwarantowanymi czasami odpowiedzi<\/td>\n<td>Switch TSN<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Co to jest TSN i kiedy ma znaczenie?<\/h2>\n<p>Time-Sensitive Networking (TSN) to zestaw standard\u00f3w IEEE 802.1, kt\u00f3re sprawiaj\u0105, \u017ce zwyk\u0142y Ethernet staje si\u0119 deterministyczny. Bez TSN du\u017cy strumie\u0144 wideo lub transfer pliku mo\u017ce chwilowo op\u00f3\u017ani\u0107 dane steruj\u0105ce. Z TSN ruch krytyczny czasowo ma gwarantowane op\u00f3\u017anienie, nawet gdy sie\u0107 jest pe\u0142na innego ruchu.<\/p>\n<ul>\n<li><b>IEEE 802.1AS<\/b> \u2013 wsp\u00f3lny zegar we wszystkich urz\u0105dzeniach.<\/li>\n<li><b>IEEE 802.1Qbv<\/b> \u2013 harmonogram okien czasowych dla ruchu krytycznego czasowo.<\/li>\n<li><b>IEEE 802.1Qbu i 802.3br<\/b> \u2013 d\u0142ugie ramki mog\u0105 zosta\u0107 przerwane, gdy pilna ramka musi przej\u015b\u0107.<\/li>\n<li><b>IEEE 802.1CB<\/b> \u2013 ramki s\u0105 wysy\u0142ane dwiema drogami, co zapewnia redundancj\u0119 bez przerw.<\/li>\n<\/ul>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f2-pl.webp\" alt=\"O\u015b czasu TSN: ka\u017cdy cykl zaczyna si\u0119 od zarezerwowanego okna na dane steruj\u0105ce, po kt\u00f3rym nast\u0119puje ruch wideo i IT\" width=\"1520\" height=\"430\" loading=\"lazy\" decoding=\"async\"><figcaption>TSN rezerwuje okno czasowe w ka\u017cdym cyklu, wi\u0119c dane steruj\u0105ce nigdy nie musz\u0105 czeka\u0107 na inny ruch.<\/figcaption><\/figure>\n<p>TSN ma znaczenie, gdy sterowanie, wideo i IT musz\u0105 wsp\u00f3\u0142dzieli\u0107 jedn\u0105 sie\u0107 przy \u015bcis\u0142ych wymaganiach czasowych, gdy sterowanie ruchem ma dzia\u0142a\u0107 przez wsp\u00f3ln\u0105 sie\u0107, a tak\u017ce w pojazdach, lotnictwie i obronno\u015bci, gdzie wiele system\u00f3w korzysta z jednej sieci szkieletowej. PROFINET i OPC UA maj\u0105 warianty TSN, a IEC\/IEEE 60802 definiuje wsp\u00f3lny profil TSN dla automatyki przemys\u0142owej.<\/p>\n<p>Typowa maszyna lub gniazdo produkcyjne nie potrzebuje dzi\u015b TSN. PROFINET i EtherNet\/IP dobrze dzia\u0142aj\u0105 ze zwyk\u0142ymi switchami zarz\u0105dzalnymi. Przy budowie instalacji, kt\u00f3ra ma s\u0142u\u017cy\u0107 15\u201320 lat, warto jednak zapyta\u0107 o obs\u0142ug\u0119 TSN.<\/p>\n<h2>Cz\u0119ste b\u0142\u0119dy<\/h2>\n<ol class=\"g-pit\">\n<li><b>Switch niezarz\u0105dzalny w sieci EtherNet\/IP.<\/b> Bez IGMP snooping multicast trafia na wszystkie porty, a proste urz\u0105dzenia mog\u0105 otrzymywa\u0107 wi\u0119cej ruchu, ni\u017c s\u0105 w stanie obs\u0142u\u017cy\u0107.<\/li>\n<li><b>P\u0119tla bez protoko\u0142u redundancji.<\/b> Je\u015bli dwa porty zostan\u0105 przez pomy\u0142k\u0119 po\u0142\u0105czone, burza rozg\u0142oszeniowa mo\u017ce unieruchomi\u0107 ca\u0142\u0105 sie\u0107. Zapobiega temu RSTP lub ochrona przed burz\u0105 (storm control).<\/li>\n<li><b>R\u00f3\u017cne protoko\u0142y pier\u015bcieniowe w jednym pier\u015bcieniu.<\/b> Protoko\u0142y pier\u015bcieniowe producent\u00f3w rzadko wsp\u00f3\u0142pracuj\u0105 mi\u0119dzy markami. Przy mieszaniu marek nale\u017cy wybra\u0107 standard, taki jak MRP lub RSTP.<\/li>\n<li><b>Za ma\u0142y bud\u017cet mocy PoE.<\/b> Trzeba sprawdzi\u0107 zar\u00f3wno moc na port, jak i ca\u0142kowity bud\u017cet mocy switcha. Osiem kamer po 30 W wymaga 240 W.<\/li>\n<li><b>Pozostawione has\u0142o domy\u015blne.<\/b> Switch zarz\u0105dzalny z fabrycznym has\u0142em to otwarte drzwi do systemu sterowania. Nale\u017cy zmieni\u0107 has\u0142a i wy\u0142\u0105czy\u0107 nieu\u017cywane us\u0142ugi.<\/li>\n<\/ol>\n<h2>Switche w ofercie SCN<\/h2>\n<p>Dostarczamy switche niezarz\u0105dzalne, zarz\u0105dzalne i TSN m.in. firm Moxa, Axiomtek, Yaskawa, Duagon, Diamond Systems i Enercon. Oferta obejmuje zar\u00f3wno ma\u0142e switche na szyn\u0119 DIN, jak i switche Layer 3 do szaf rack, switche M12 do poci\u0105g\u00f3w i switche VPX do system\u00f3w obronnych.<\/p>\n<h3>Przyk\u0142ady z naszej oferty<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/pl\/produkt\/eacsw-pl\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/winmate-eacsw-main.webp\" alt=\"Winmate EACSW Morski switch Ethernet z 8 portami\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Winmate<\/span><span class=\"g-pn\">EACSW Morski switch Ethernet z 8 portami<\/span><span class=\"g-pw\">Niezarz\u0105dzalny switch 8-portowy \u2013 plug and play, redundantne wej\u015bcia zasilania 12\u201348 VDC, monta\u017c na szynie DIN lub \u015bcianie.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/pl\/produkt\/pn5-rd-pn8-rd-managed-profinet-switch-pl\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/yaskawa-pn5-rd-pn8-rd-main.webp\" alt=\"Yaskawa PN5-RD \/ PN8-RD zarz\u0105dzalny switch PROFINET\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Yaskawa<\/span><span class=\"g-pn\">PN5-RD \/ PN8-RD zarz\u0105dzalny switch PROFINET<\/span><span class=\"g-pw\">Zarz\u0105dzalny switch PROFINET (Conformance Class B) z Turbo Ring, VLAN, QoS i IGMP snooping, na szyn\u0119 DIN.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/pl\/produkt\/tsn-g5016-pl\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/moxa-tsn-g5016-main.webp\" alt=\"Moxa TSN-G5016 16-portowy gigabitowy switch TSN\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Moxa<\/span><span class=\"g-pn\">TSN-G5016 16-portowy gigabitowy switch TSN<\/span><span class=\"g-pw\">Zarz\u0105dzalny switch TSN z synchronizacj\u0105 czasu IEEE 802.1AS i harmonogramem IEEE 802.1Qbv.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/pl\/kategoria-produktu\/produkty\/network-products-pl\/ethernet-pl\/managed-switches-pl\/\">Switche zarz\u0105dzalne<\/a><a href=\"https:\/\/scn.eu\/pl\/kategoria-produktu\/produkty\/network-products-pl\/ethernet-pl\/unmanaged-switches-pl\/\">Switche niezarz\u0105dzalne<\/a><a href=\"https:\/\/scn.eu\/pl\/kategoria-produktu\/produkty\/network-products-pl\/ethernet-pl\/time-sensitive-networking-pl\/\">Time-Sensitive Networking<\/a><a href=\"https:\/\/scn.eu\/pl\/kategoria-produktu\/produkty\/network-products-pl\/ethernet-pl\/mil-ethernet-switches-pl\/\">Switche Ethernet MIL<\/a><a href=\"https:\/\/scn.eu\/pl\/kategoria-produktu\/produkty\/network-products-pl\/ethernet-pl\/\">Switche Ethernet<\/a><\/div>\n<div class=\"g-cta\">\n<p>Trudno oceni\u0107, jakiego switcha potrzebuje sie\u0107? Wystarczy opisa\u0107 instalacj\u0119 naszym in\u017cynierom \u2013 odpowied\u017a w ci\u0105gu 24 godzin.<\/p>\n<p><a href=\"https:\/\/scn.eu\/pl\/kontakt\/\">Zapytaj in\u017cyniera<\/a><\/div>\n<h2>Najcz\u0119\u015bciej zadawane pytania<\/h2>\n<details>\n<summary>Czy mo\u017cna \u0142\u0105czy\u0107 switche zarz\u0105dzalne i niezarz\u0105dzalne?<\/summary>\n<p>Tak, wsp\u00f3\u0142pracuj\u0105 w tej samej sieci. VLAN, IGMP snooping i redundancja dzia\u0142aj\u0105 jednak tylko w switchach zarz\u0105dzalnych, dlatego nale\u017cy je umieszcza\u0107 tam, gdzie zbiega si\u0119 ruch.<\/p>\n<\/details>\n<details>\n<summary>Co to jest IGMP snooping?<\/summary>\n<p>Funkcja, dzi\u0119ki kt\u00f3rej switch \u015bledzi, kt\u00f3re urz\u0105dzenia chc\u0105 odbiera\u0107 dany strumie\u0144 multicast, i wysy\u0142a go tylko na ich porty. Bez niej multicast trafia wsz\u0119dzie.<\/p>\n<\/details>\n<details>\n<summary>Czy PROFINET wymaga switcha zarz\u0105dzalnego?<\/summary>\n<p>Nie zawsze. Conformance Class A dzia\u0142a ze zwyk\u0142ymi switchami, ale Class B wymaga switchy z diagnostyk\u0105 PROFINET, w tym informacjami o topologii przez LLDP i SNMP.<\/p>\n<\/details>\n<details>\n<summary>Czym r\u00f3\u017cni si\u0119 RSTP od MRP?<\/summary>\n<p>RSTP to og\u00f3lny standard IEEE dzia\u0142aj\u0105cy w dowolnej topologii, ale odtworzenie sieci mo\u017ce trwa\u0107 do kilku sekund. MRP jest przeznaczony dla pier\u015bcieni w sieciach przemys\u0142owych i przywraca \u0142\u0105czno\u015b\u0107 w gwarantowanym czasie, zwykle maksymalnie 200 ms.<\/p>\n<\/details>\n<details>\n<summary>Czy zwyk\u0142e urz\u0105dzenia dzia\u0142aj\u0105 w sieci TSN?<\/summary>\n<p>Tak, switche TSN przekazuj\u0105 zwyk\u0142y ruch Ethernet. Gwarancje op\u00f3\u017anie\u0144 dotycz\u0105 jednak tylko ruchu obj\u0119tego harmonogramem, a ka\u017cdy switch na trasie musi obs\u0142ugiwa\u0107 TSN.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Switch niezarz\u0105dzalny \u0142\u0105czy urz\u0105dzenia bez \u017cadnych ustawie\u0144. Switch zarz\u0105dzalny pozwala sterowa\u0107 ruchem, nadawa\u0107 mu priorytety i go monitorowa\u0107. W tym poradniku wyja\u015bniamy r\u00f3\u017cnice, wymagania przemys\u0142u i to, kiedy warto wybra\u0107 Time-Sensitive Networking (TSN).<\/p>\n","protected":false},"author":11,"featured_media":8234446,"template":"","meta":{"_yoast_wpseo_focuskw":"switch zarz\u0105dzalny","_yoast_wpseo_metadesc":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[871,870,873,864],"_scn_guide_sectors":[1011,1080,10762],"_scn_guide_type":"tech","_scn_guide_order":18,"footnotes":""},"class_list":["post-8234639","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN | SCN<\/title>\n<meta name=\"description\" content=\"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN | SCN\" \/>\n<meta property=\"og:description\" content=\"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:32:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-pl.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"520\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minut\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/\",\"name\":\"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-switch-f1-pl.webp\",\"datePublished\":\"2026-10-24T17:26:47+00:00\",\"dateModified\":\"2026-10-24T17:32:38+00:00\",\"description\":\"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-switch-f1-pl.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-switch-f1-pl.webp\",\"width\":1520,\"height\":520,\"caption\":\"Cztery switche w pier\u015bcieniu. \u0141\u0105cze mi\u0119dzy switchem 2 i 3 jest przerwane, a zablokowane \u0142\u0105cze zapasowe mi\u0119dzy switchem 4 i 1 otwiera si\u0119, wi\u0119c ruch biegnie drug\u0105 stron\u0105\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/poradniki\\\/switch-zarzadzalny-czy-niezarzadzalny\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/pl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/pl\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/pl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/pl\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/pl\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN | SCN","description":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/","og_locale":"pl_PL","og_type":"article","og_title":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN | SCN","og_description":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.","og_url":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:32:38+00:00","og_image":[{"width":1520,"height":520,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-pl.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Szacowany czas czytania":"7 minut"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/","url":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/","name":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-pl.webp","datePublished":"2026-10-24T17:26:47+00:00","dateModified":"2026-10-24T17:32:38+00:00","description":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny: r\u00f3\u017cnice w VLAN, QoS, IGMP snooping, redundancji i PoE \u2013 oraz kiedy sie\u0107 przemys\u0142owa potrzebuje TSN.","breadcrumb":{"@id":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-pl.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-pl.webp","width":1520,"height":520,"caption":"Cztery switche w pier\u015bcieniu. \u0141\u0105cze mi\u0119dzy switchem 2 i 3 jest przerwane, a zablokowane \u0142\u0105cze zapasowe mi\u0119dzy switchem 4 i 1 otwiera si\u0119, wi\u0119c ruch biegnie drug\u0105 stron\u0105"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/pl\/poradniki\/switch-zarzadzalny-czy-niezarzadzalny\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/pl\/"},{"@type":"ListItem","position":2,"name":"Switch zarz\u0105dzalny czy niezarz\u0105dzalny \u2013 i kiedy TSN"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/pl\/#website","url":"https:\/\/scn.eu\/pl\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/pl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/scn.eu\/pl\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/pl\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/scn.eu\/pl\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/pl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/scn_guide\/8234639","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/scn_guide\/8234639\/revisions"}],"predecessor-version":[{"id":8235029,"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/scn_guide\/8234639\/revisions\/8235029"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/media\/8234446"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/pl\/wp-json\/wp\/v2\/media?parent=8234639"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}