{"id":8234579,"date":"2026-10-24T17:26:47","date_gmt":"2026-10-24T17:26:47","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234579"},"modified":"2026-10-24T17:30:36","modified_gmt":"2026-10-24T17:30:36","slug":"managed-svitsj","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/","title":{"rendered":"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN?"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN?<\/h1>\n<p class=\"g-lead\">En unmanaged svitsj kobler sammen enheter uten innstillinger. En managed svitsj lar deg styre, prioritere og overv\u00e5ke trafikken. Her g\u00e5r vi gjennom forskjellene, hva industrien krever og n\u00e5r Time-Sensitive Networking (TSN) er verdt \u00e5 velge.<\/p>\n<div class=\"g-short\"><b class=\"t\">Kort svar<\/b><\/p>\n<ul>\n<li><b>Unmanaged<\/b> \u2013 plug and play uten innstillinger. Holder for en liten, isolert maskin eller celle.<\/li>\n<li><b>Managed<\/b> \u2013 VLAN, prioritering, IGMP snooping, redundans og diagnostikk. Trengs n\u00e5r nettet vokser eller kobles til fabrikknettet.<\/li>\n<li><b>Smart svitsj<\/b> \u2013 en mellomting med de viktigste funksjonene og enklere innstillinger.<\/li>\n<li><b>Ring<\/b> \u2013 med en ringprotokoll kobler nettet om til reserveveien p\u00e5 millisekunder ved kabelbrudd.<\/li>\n<li><b>TSN<\/b> \u2013 garantert forsinkelse p\u00e5 standard Ethernet. Aktuelt n\u00e5r styring, video og IT skal dele samme nett.<\/li>\n<\/ul>\n<\/div>\n<h2>Hva er forskjellen?<\/h2>\n<p>En svitsj sender hver Ethernet-ramme til riktig port. En unmanaged svitsj gj\u00f8r bare det: den l\u00e6rer adressene selv og fungerer med en gang. En managed (administrert) svitsj kan konfigureres via nettleser, kommandolinje eller SNMP. Da kan du dele opp nettet, prioritere viktig trafikk, bygge redundans og se hva som skjer p\u00e5 hver port.<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Funksjon<\/th>\n<th>Unmanaged<\/th>\n<th>Managed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">Innstillinger<\/td>\n<td>Ingen<\/td>\n<td>Web, kommandolinje, SNMP<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">VLAN<\/td>\n<td>Nei<\/td>\n<td>Ja, IEEE 802.1Q<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Prioritering<\/td>\n<td>Noen ganger fast<\/td>\n<td>Ja, justerbar<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">IGMP snooping<\/td>\n<td>Nei<\/td>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Redundans<\/td>\n<td>Nei<\/td>\n<td>RSTP, MRP og ringprotokoller<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Diagnostikk<\/td>\n<td>Lysdioder, noen ganger alarmrel\u00e9<\/td>\n<td>Portstatistikk, alarmer, logger, portspeiling<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Sikkerhet<\/td>\n<td>Ingen<\/td>\n<td>Brukerkontoer, portl\u00e5sing, IEEE 802.1X<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Pris<\/td>\n<td>Lavere<\/td>\n<td>H\u00f8yere<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Mellom dem finnes smarte svitsjer, noen ganger kalt lett administrerte. De har et utvalg av funksjonene, for eksempel VLAN, RSTP og st\u00f8tte for PROFINET eller EtherNet\/IP, men er enklere \u00e5 stille inn.<\/p>\n<h2>Funksjonene som gj\u00f8r en forskjell i industrien<\/h2>\n<h3>VLAN<\/h3>\n<p>Med VLAN deles ett fysisk nett i flere logiske. Styresystemer, kameraer og kontortrafikk kan g\u00e5 gjennom de samme svitsjene uten \u00e5 se hverandre. Det begrenser forstyrrelser og gj\u00f8r nettet sikrere.<\/p>\n<h3>Prioritering (QoS)<\/h3>\n<p>Trafikken merkes med prioritet etter IEEE 802.1p, slik at I\/O-data g\u00e5r foran filoverf\u00f8ringer og video n\u00e5r en link er hardt belastet.<\/p>\n<h3>IGMP snooping<\/h3>\n<p>Svitsjen sender multicast bare til de portene som har bedt om den. Det er viktig i EtherNet\/IP-nett og for videostr\u00f8mmer, der multicast ellers fyller hele nettet.<\/p>\n<h3>Redundans<\/h3>\n<p>RSTP (IEEE 802.1w) er standard og fungerer mellom ulike merker, men omkoblingen kan ta fra under ett sekund til flere sekunder i st\u00f8rre nett. Ringprotokoller som MRP (IEC 62439-2) og produsentenes egne, for eksempel Moxa Turbo Ring, kobler om innen titalls til hundretalls millisekunder. HSR og PRP (IEC 62439-3) sender trafikken to veier samtidig og gir avbruddsfri redundans, for eksempel i transformatorstasjoner.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-no.webp\" alt=\"Fire svitsjer i en ring. Linken mellom svitsj 2 og 3 er brutt, og den blokkerte reservelinken mellom svitsj 4 og 1 \u00e5pnes slik at trafikken g\u00e5r den andre veien\" width=\"1520\" height=\"520\" loading=\"lazy\" decoding=\"async\"><figcaption>En ring med fire svitsjer: ved kabelbrudd \u00e5pnes den blokkerte reservelinken.<\/figcaption><\/figure>\n<h3>Diagnostikk og PoE<\/h3>\n<p>En managed svitsj viser linkstatus, feil og trafikk per port og kan varsle via SNMP, e-post eller rel\u00e9utgang. PoE forsyner kameraer, tilgangspunkter og sensorer via nettverkskabelen: opptil 15,4 W per port med IEEE 802.3af, 30 W med 802.3at og opptil 90 W med 802.3bt, regnet ved svitsjen.<\/p>\n<h2>Hva krever industrien av en svitsj?<\/h2>\n<ul>\n<li><b>Temperatur<\/b> \u2013 industrisvitsjer finnes for \u221240 til 75 \u00b0C, uten vifte.<\/li>\n<li><b>Montering<\/b> \u2013 DIN-skinne eller vegg med metallkabinett, og 19-tommers rack for stamnett.<\/li>\n<li><b>Str\u00f8mforsyning<\/b> \u2013 doble innganger for likespenning, for eksempel 12\u201348 V DC, og alarmrel\u00e9 ved bortfall av forsyning.<\/li>\n<li><b>Kontakter og tetthet<\/b> \u2013 M12 i stedet for RJ45 der det rister, og IP67 for kj\u00f8ret\u00f8y og utend\u00f8rs bruk.<\/li>\n<li><b>Godkjenninger<\/b> \u2013 EN 50155 for jernbanekj\u00f8ret\u00f8y, IEC 61850-3 for transformatorstasjoner og Class I Division 2 eller ATEX sone 2 for eksplosjonsfarlige omr\u00e5der.<\/li>\n<\/ul>\n<h3>Hvilken svitsj passer hvor?<\/h3>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Hvis du \u2026<\/th>\n<th>\u2026 velg<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>bygger en liten maskin med f\u00e5 enheter og uten fabrikknett<\/td>\n<td>Unmanaged svitsj<\/td>\n<\/tr>\n<tr>\n<td>leverer maskiner som kobles til kundens nett<\/td>\n<td>Managed eller smart svitsj med VLAN og st\u00f8tte for PROFINET eller EtherNet\/IP<\/td>\n<\/tr>\n<tr>\n<td>har mange EtherNet\/IP-enheter eller videostr\u00f8mmer<\/td>\n<td>Managed svitsj med IGMP snooping<\/td>\n<\/tr>\n<tr>\n<td>driver en prosess der et kabelbrudd ikke f\u00e5r stoppe produksjonen<\/td>\n<td>Managed svitsj med ringprotokoll eller MRP<\/td>\n<\/tr>\n<tr>\n<td>forsyner kameraer og tilgangspunkter i tunneler, parkeringshus eller havner<\/td>\n<td>Svitsj med PoE<\/td>\n<\/tr>\n<tr>\n<td>bygger nett i tog og trikker<\/td>\n<td>M12-svitsj etter EN 50155<\/td>\n<\/tr>\n<tr>\n<td>bygger transformatorstasjoner og koblingsanlegg<\/td>\n<td>Svitsj etter IEC 61850-3, ofte med PRP eller HSR<\/td>\n<\/tr>\n<tr>\n<td>bygger kj\u00f8ret\u00f8y, fart\u00f8y eller forsvarssystemer<\/td>\n<td>IP67-klassifisert svitsj eller VPX-svitsj<\/td>\n<\/tr>\n<tr>\n<td>skal blande styring, video og IT med garanterte responstider<\/td>\n<td>TSN-svitsj<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Hva er TSN, og n\u00e5r spiller det en rolle?<\/h2>\n<p>Time-Sensitive Networking (TSN) er en samling standarder fra IEEE 802.1 som gj\u00f8r vanlig Ethernet deterministisk. Uten TSN kan en stor videostr\u00f8m eller filoverf\u00f8ring forsinke styredata et kort \u00f8yeblikk. Med TSN f\u00e5r den tidskritiske trafikken garantert forsinkelse, ogs\u00e5 n\u00e5r nettet er fullt av annen trafikk.<\/p>\n<ul>\n<li><b>IEEE 802.1AS<\/b> \u2013 felles klokke i alle enheter.<\/li>\n<li><b>IEEE 802.1Qbv<\/b> \u2013 planlagte tidsluker for den tidskritiske trafikken.<\/li>\n<li><b>IEEE 802.1Qbu og 802.3br<\/b> \u2013 lange rammer kan avbrytes n\u00e5r en hasteramme skal fram.<\/li>\n<li><b>IEEE 802.1CB<\/b> \u2013 rammer sendes to veier for avbruddsfri redundans.<\/li>\n<\/ul>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f2-no.webp\" alt=\"Tidsplan i et TSN-nett: hver syklus starter med en reservert tidsluke for styredata, deretter \u00f8vrig trafikk som video og IT\" width=\"1520\" height=\"430\" loading=\"lazy\" decoding=\"async\"><figcaption>TSN reserverer en tidsluke i hver syklus, slik at styredata aldri trenger \u00e5 vente p\u00e5 annen trafikk.<\/figcaption><\/figure>\n<p>TSN spiller en rolle n\u00e5r styring, video og IT skal dele samme nett med strenge tidskrav, n\u00e5r bevegelsesstyring skal g\u00e5 over et felles nett, og i kj\u00f8ret\u00f8y, luftfart og forsvar der mange systemer deler et stamnett. PROFINET og OPC UA har varianter for TSN, og IEC\/IEEE 60802 beskriver en felles TSN-profil for industriell automasjon.<\/p>\n<p>For en vanlig maskin eller produksjonscelle trengs ikke TSN i dag. PROFINET og EtherNet\/IP fungerer godt med vanlige managed svitsjer. Bygger du et anlegg som skal leve i 15\u201320 \u00e5r, kan det likevel v\u00e6re lurt \u00e5 sp\u00f8rre etter TSN-st\u00f8tte.<\/p>\n<h2>Vanlige feil<\/h2>\n<ol class=\"g-pit\">\n<li><b>Unmanaged svitsj i et EtherNet\/IP-nett.<\/b> Uten IGMP snooping sendes multicast til alle porter, og enkle enheter kan f\u00e5 mer trafikk enn de t\u00e5ler.<\/li>\n<li><b>En sl\u00f8yfe uten redundansprotokoll.<\/b> Kobles to porter sammen ved en feil, oppst\u00e5r en broadcaststorm som kan sl\u00e5 ut hele nettet. RSTP eller stormbeskyttelse hindrer det.<\/li>\n<li><b>Ulike ringprotokoller i samme ring.<\/b> Produsentenes egne ringprotokoller fungerer sjelden mellom merker. Blander du merker, velg en standard som MRP eller RSTP.<\/li>\n<li><b>PoE-budsjettet holder ikke.<\/b> Sjekk b\u00e5de effekten per port og svitsjens totale budsjett. \u00c5tte kameraer p\u00e5 30 W krever 240 W.<\/li>\n<li><b>Standardpassordet er ikke endret.<\/b> En managed svitsj med fabrikkpassord er en \u00e5pen d\u00f8r inn i styresystemet. Bytt passord og sl\u00e5 av tjenester som ikke brukes.<\/li>\n<\/ol>\n<h2>Svitsjer hos SCN<\/h2>\n<p>Vi har unmanaged, managed og TSN-svitsjer fra blant andre Moxa, Axiomtek, Yaskawa, Duagon, Diamond Systems og Enercon. Sortimentet spenner fra sm\u00e5 svitsjer for DIN-skinne til Layer 3-svitsjer for rack, M12-svitsjer for tog og VPX-svitsjer for forsvarssystemer.<\/p>\n<h3>Eksempler fra v\u00e5rt sortiment<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/no\/produkt\/eacsw-no\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/winmate-eacsw-main.webp\" alt=\"Winmate EACSW maritim Ethernet-svitsj med 8 porter\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Winmate<\/span><span class=\"g-pn\">EACSW maritim Ethernet-svitsj med 8 porter<\/span><span class=\"g-pw\">Unmanaged svitsj med \u00e5tte porter \u2013 plug and play, doble forsyningsinnganger 12\u201348 V DC, for DIN-skinne eller vegg.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/no\/produkt\/pn5-rd-pn8-rd-managed-profinet-switch-no\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/yaskawa-pn5-rd-pn8-rd-main.webp\" alt=\"Yaskawa PN5-RD \/ PN8-RD administrert PROFINET-svitsj\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Yaskawa<\/span><span class=\"g-pn\">PN5-RD \/ PN8-RD administrert PROFINET-svitsj<\/span><span class=\"g-pw\">Managed PROFINET-svitsj (Conformance Class B) med Turbo Ring, VLAN, QoS og IGMP snooping for DIN-skinne.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/no\/produkt\/tsn-g5016-no\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/moxa-tsn-g5016-main.webp\" alt=\"Moxa TSN-G5016 TSN-switch med 16 gigabitporter\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Moxa<\/span><span class=\"g-pn\">TSN-G5016 TSN-switch med 16 gigabitporter<\/span><span class=\"g-pw\">Managed TSN-svitsj med tidssynkronisering etter IEEE 802.1AS og tidsplanlegging etter IEEE 802.1Qbv.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/no\/produktkategori\/products-no\/network-products-no\/ethernet-no\/managed-switches-no\/\">Managed svitsjer<\/a><a href=\"https:\/\/scn.eu\/no\/produktkategori\/products-no\/network-products-no\/ethernet-no\/unmanaged-switches-no\/\">Unmanaged svitsjer<\/a><a href=\"https:\/\/scn.eu\/no\/produktkategori\/products-no\/network-products-no\/ethernet-no\/time-sensitive-networking-no\/\">Time-Sensitive Networking (TSN)<\/a><a href=\"https:\/\/scn.eu\/no\/produktkategori\/products-no\/network-products-no\/ethernet-no\/mil-ethernet-switches-no\/\">MIL Ethernet-svitsjer<\/a><a href=\"https:\/\/scn.eu\/no\/produktkategori\/products-no\/network-products-no\/ethernet-no\/\">Nettverkssvitsjer<\/a><\/div>\n<div class=\"g-cta\">\n<p>Usikker p\u00e5 hvilken svitsj nettet trenger? Beskriv anlegget for ingeni\u00f8rene v\u00e5re \u2013 du f\u00e5r svar innen 24 timer.<\/p>\n<p><a href=\"https:\/\/scn.eu\/no\/kontakt\/\">Sp\u00f8r en ingeni\u00f8r<\/a><\/div>\n<h2>Vanlige sp\u00f8rsm\u00e5l<\/h2>\n<details>\n<summary>Kan man blande managed og unmanaged svitsjer?<\/summary>\n<p>Ja, de fungerer sammen i samme nett. Men VLAN, IGMP snooping og redundans gjelder bare i de managed svitsjene, s\u00e5 plasser dem der trafikken m\u00f8tes.<\/p>\n<\/details>\n<details>\n<summary>Hva er IGMP snooping?<\/summary>\n<p>En funksjon der svitsjen holder rede p\u00e5 hvilke enheter som vil motta en multicaststr\u00f8m, og bare sender den til portene deres. Uten den sendes multicast ut overalt.<\/p>\n<\/details>\n<details>\n<summary>Trenger PROFINET en managed svitsj?<\/summary>\n<p>Ikke alltid. I Conformance Class A holder vanlige svitsjer, men Class B krever svitsjer med PROFINET-diagnostikk, blant annet topologiinformasjon via LLDP og SNMP.<\/p>\n<\/details>\n<details>\n<summary>Hva er forskjellen p\u00e5 RSTP og MRP?<\/summary>\n<p>RSTP er en generell IEEE-standard som fungerer i alle topologier, men omkoblingen kan ta opptil noen sekunder. MRP er laget for ringer i industrinett og kobler om innen en garantert tid, vanligvis maksimalt 200 ms.<\/p>\n<\/details>\n<details>\n<summary>Fungerer vanlige enheter i et TSN-nett?<\/summary>\n<p>Ja, TSN-svitsjer videresender vanlig Ethernet-trafikk. Garantiene for forsinkelse gjelder likevel bare den planlagte trafikken, og alle svitsjer p\u00e5 veien m\u00e5 st\u00f8tte TSN.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>En unmanaged svitsj kobler sammen enheter uten innstillinger. En managed svitsj lar deg styre, prioritere og overv\u00e5ke trafikken. Her g\u00e5r vi gjennom forskjellene, hva industrien krever og n\u00e5r Time-Sensitive Networking (TSN) er verdt \u00e5 velge.<\/p>\n","protected":false},"author":11,"featured_media":8234443,"template":"","meta":{"_yoast_wpseo_focuskw":"managed svitsj","_yoast_wpseo_metadesc":"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[871,870,873,864],"_scn_guide_sectors":[1011,1080,10762],"_scn_guide_type":"tech","_scn_guide_order":18,"footnotes":""},"class_list":["post-8234579","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN? | SCN<\/title>\n<meta name=\"description\" content=\"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/\" \/>\n<meta property=\"og:locale\" content=\"nb_NO\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN? | SCN\" \/>\n<meta property=\"og:description\" content=\"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:30:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-no.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"520\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ansl. lesetid\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/\",\"name\":\"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN? | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-switch-f1-no.webp\",\"datePublished\":\"2026-10-24T17:26:47+00:00\",\"dateModified\":\"2026-10-24T17:30:36+00:00\",\"description\":\"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/#breadcrumb\"},\"inLanguage\":\"nb-NO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nb-NO\",\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-switch-f1-no.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-switch-f1-no.webp\",\"width\":1520,\"height\":520,\"caption\":\"Fire svitsjer i en ring. Linken mellom svitsj 2 og 3 er brutt, og den blokkerte reservelinken mellom svitsj 4 og 1 \u00e5pnes slik at trafikken g\u00e5r den andre veien\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/guider\\\/managed-svitsj\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/no\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/no\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/no\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nb-NO\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/no\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nb-NO\",\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/no\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN? | SCN","description":"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/","og_locale":"nb_NO","og_type":"article","og_title":"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN? | SCN","og_description":"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.","og_url":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:30:36+00:00","og_image":[{"width":1520,"height":520,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-no.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Ansl. lesetid":"6 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/","url":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/","name":"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN? | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/no\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-no.webp","datePublished":"2026-10-24T17:26:47+00:00","dateModified":"2026-10-24T17:30:36+00:00","description":"Managed eller unmanaged svitsj? Slik skiller de seg: VLAN, QoS, IGMP snooping, redundans og PoE \u2013 og n\u00e5r du trenger TSN i et industrielt nett.","breadcrumb":{"@id":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/#breadcrumb"},"inLanguage":"nb-NO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/no\/guider\/managed-svitsj\/"]}]},{"@type":"ImageObject","inLanguage":"nb-NO","@id":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-no.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-switch-f1-no.webp","width":1520,"height":520,"caption":"Fire svitsjer i en ring. Linken mellom svitsj 2 og 3 er brutt, og den blokkerte reservelinken mellom svitsj 4 og 1 \u00e5pnes slik at trafikken g\u00e5r den andre veien"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/no\/guider\/managed-svitsj\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/no\/"},{"@type":"ListItem","position":2,"name":"Managed eller unmanaged svitsj \u2013 og n\u00e5r trengs TSN?"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/no\/#website","url":"https:\/\/scn.eu\/no\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/no\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/no\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nb-NO"},{"@type":"Organization","@id":"https:\/\/scn.eu\/no\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/no\/","logo":{"@type":"ImageObject","inLanguage":"nb-NO","@id":"https:\/\/scn.eu\/no\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/no\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/scn_guide\/8234579","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/scn_guide\/8234579\/revisions"}],"predecessor-version":[{"id":8235022,"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/scn_guide\/8234579\/revisions\/8235022"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/media\/8234443"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/no\/wp-json\/wp\/v2\/media?parent=8234579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}