{"id":8235434,"date":"2026-10-24T17:32:03","date_gmt":"2026-10-24T17:32:03","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8235434"},"modified":"2026-10-24T17:32:05","modified_gmt":"2026-10-24T17:32:05","slug":"hmi-paneeli","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/","title":{"rendered":"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean<\/h1>\n<p class=\"g-lead\">K\u00e4ytt\u00f6paneeli on se osa konetta, jonka k\u00e4ytt\u00e4j\u00e4 n\u00e4kee. T\u00e4ss\u00e4 oppaassa kerrotaan HMI-paneelin ja paneeli-PC:n erot, miten paneeli kommunikoi PLC:n kanssa ja mit\u00e4 ohjelmistossa, h\u00e4lytyksiss\u00e4 ja et\u00e4yhteyksiss\u00e4 kannattaa huomioida.<\/p>\n<div class=\"g-short\"><b class=\"t\">Lyhyesti<\/b><\/p>\n<ul>\n<li><b>HMI<\/b> \u2013 Human Machine Interface eli ihmisen ja koneen k\u00e4ytt\u00f6liittym\u00e4, jossa k\u00e4ytt\u00e4j\u00e4 n\u00e4kee tilan, muuttaa arvoja ja kuittaa h\u00e4lytyksi\u00e4.<\/li>\n<li><b>HMI-paneeli<\/b> \u2013 kosketusn\u00e4ytt\u00f6 valmiilla HMI-ohjelmistolla. Yksinkertainen, nopea ottaa k\u00e4ytt\u00f6\u00f6n ja riitt\u00e4\u00e4 useimpiin koneisiin.<\/li>\n<li><b>Paneeli-PC ja SCADA<\/b> \u2013 kun tarvitset Windowsia, useita PLC:it\u00e4, tietokantoja tai omaa ohjelmistoa.<\/li>\n<li><b>Tiedonsiirto<\/b> \u2013 tarkista, ett\u00e4 paneelissa on ajuri PLC:llesi, esimerkiksi Siemens, Rockwell, Omron tai Modbus, tai k\u00e4yt\u00e4 OPC UA:ta.<\/li>\n<li><b>Et\u00e4yhteys<\/b> \u2013 s\u00e4\u00e4st\u00e4\u00e4 matkoja, mutta vaatii VPN:n, henkil\u00f6kohtaiset k\u00e4ytt\u00e4j\u00e4tunnukset ja lokituksen.<\/li>\n<\/ul>\n<\/div>\n<h2>Mik\u00e4 on HMI?<\/h2>\n<p>HMI tulee sanoista Human Machine Interface. K\u00e4yt\u00e4nn\u00f6ss\u00e4 se on yleens\u00e4 kaapin oveen asennettu kosketusn\u00e4ytt\u00f6, joka n\u00e4ytt\u00e4\u00e4 koneen tilan, mittausarvot, h\u00e4lytykset ja trendit ja jolla k\u00e4ytt\u00e4j\u00e4 k\u00e4ynnist\u00e4\u00e4, pys\u00e4ytt\u00e4\u00e4 ja muuttaa asetuksia. Yksinkertaisissa koneissa painikkeet ja merkkivalot riitt\u00e4v\u00e4t edelleen.<\/p>\n<p>HMI ei itse ohjaa konetta \u2013 sen tekee PLC. Paneeli lukee ja kirjoittaa PLC:n muuttujia, joita kutsutaan tageiksi. Siksi paneelin voi vaihtaa muuttamatta ohjauslogiikkaa. Turvatoiminnot, kuten h\u00e4t\u00e4seis, on aina johdotettava turvapiiriin \u2013 ei koskaan painikkeeksi n\u00e4yt\u00f6lle.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-hmi-f1-fi.webp\" alt=\"HMI-paneeli lukee ja kirjoittaa PLC:n tageja, l\u00e4hett\u00e4\u00e4 dataa SCADAan OPC UA:n kautta ja on et\u00e4k\u00e4ytett\u00e4viss\u00e4 VPN-reitittimen kautta\" width=\"1520\" height=\"544\" loading=\"lazy\" decoding=\"async\"><figcaption>HMI-paneeli n\u00e4ytt\u00e4\u00e4 ja muuttaa PLC:n arvoja. Ohjaus- ja turvatoiminnot pysyv\u00e4t PLC:ss\u00e4 ja turvapiiriss\u00e4.<\/figcaption><\/figure>\n<h2>HMI-paneeli vai paneeli-PC ja SCADA?<\/h2>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Ominaisuus<\/th>\n<th>HMI-paneeli<\/th>\n<th>Paneeli-PC ja SCADA-ohjelmisto<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">K\u00e4ytt\u00f6j\u00e4rjestelm\u00e4<\/td>\n<td>Sulautettu j\u00e4rjestelm\u00e4, jota ei tarvitse yll\u00e4pit\u00e4\u00e4<\/td>\n<td>Windows tai Linux<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Ohjelmisto<\/td>\n<td>Valmistajan konfigurointity\u00f6kalu<\/td>\n<td>SCADA- tai HMI-ohjelmisto ja ajonaikainen lisenssi<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Sopii<\/td>\n<td>Yksi kone tai linja, jossa on yksi tai muutama PLC<\/td>\n<td>Useita koneita, tietokannat, raportit ja MES<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Yll\u00e4pito<\/td>\n<td>Nopea k\u00e4ytt\u00f6\u00f6notto, v\u00e4h\u00e4n p\u00e4ivityksi\u00e4<\/td>\n<td>Vaatii tietoturvap\u00e4ivityksi\u00e4 ja IT-yll\u00e4pitoa<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Hinta<\/td>\n<td>Edullisempi<\/td>\n<td>Kalliimpi, mutta joustavampi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Raja h\u00e4m\u00e4rtyy. Nykyaikaiset HMI-paneelit voivat n\u00e4ytt\u00e4\u00e4 verkkosivuja, kirjata tietokantoihin ja joskus ajaa IEC 61131-3 -standardin mukaisia PLC-ohjelmia CODESYSill\u00e4. On my\u00f6s n\u00e4yt\u00f6tt\u00f6mi\u00e4 DIN-kiskoon asennettavia HMI-palvelimia, jotka n\u00e4ytt\u00e4v\u00e4t k\u00e4ytt\u00f6liittym\u00e4n tableteilla tai tavallisilla n\u00e4yt\u00f6ill\u00e4. N\u00e4yt\u00f6n kokoa, kosketustekniikkaa ja IP-luokkaa k\u00e4sitell\u00e4\u00e4n paneeli-PC-oppaassamme.<\/p>\n<h2>Tiedonsiirto PLC:n kanssa<\/h2>\n<p>Paneeli kommunikoi PLC:n kanssa PLC:n protokollaa tukevan ajurin kautta. Se on ensimm\u00e4inen tarkistettava asia: onko PLC-perheellesi ajuria, ja mink\u00e4 liit\u00e4nn\u00e4n kautta?<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>PLC tai protokolla<\/th>\n<th>Tyypillinen liit\u00e4nt\u00e4<\/th>\n<th>Huomioi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">Siemens S7-1200 ja S7-1500<\/td>\n<td>Ethernet<\/td>\n<td>Tukeeko paneeli optimoituja datablokkeja, vai onko PUT\/GET otettava k\u00e4ytt\u00f6\u00f6n PLC:ss\u00e4?<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Siemens S7-300 ja S7-400<\/td>\n<td>MPI, PROFIBUS tai Ethernet<\/td>\n<td>Vanhemmissa laitoksissa on usein vain MPI<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Rockwell (Allen-Bradley)<\/td>\n<td>EtherNet\/IP<\/td>\n<td>Tagit voi usein lukea nimell\u00e4 suoraan PLC-projektista<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Omron<\/td>\n<td>EtherNet\/IP tai FINS<\/td>\n<td>Valitse ajuri PLC-sarjan mukaan<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Modbus RTU ja Modbus TCP<\/td>\n<td>RS-485 tai Ethernet<\/td>\n<td>Toimii l\u00e4hes kaiken kanssa, mutta vaatii rekisterikartan<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">OPC UA<\/td>\n<td>Ethernet<\/td>\n<td>Valmistajariippumaton ja sis\u00e4\u00e4nrakennettu tietoturva, yleinen SCADAn ja MES:n suuntaan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Monet paneelit voivat kommunikoida usean PLC:n kanssa yht\u00e4 aikaa ja toimia yksinkertaisena yhdysk\u00e4yt\u00e4v\u00e4n\u00e4 protokollien v\u00e4lill\u00e4. Teollisuusprotokollia k\u00e4sittelev\u00e4 oppaamme kertoo niist\u00e4 tarkemmin.<\/p>\n<h2>Ohjelmisto, h\u00e4lytykset, reseptit ja lokitus<\/h2>\n<p>Jokaisella valmistajalla on oma konfigurointiohjelmistonsa, esimerkiksi EasyBuilder Pro Weintekin ja Movicon Yaskawan paneeleille. Vertaa lisenssimalleja: HMI-paneeleissa kehitysty\u00f6kalu on usein maksuton, kun taas SCADA-ohjelmistoissa on yleens\u00e4 tagien m\u00e4\u00e4r\u00e4\u00e4n perustuva ajonaikainen lisenssi. Tarkista my\u00f6s, ett\u00e4 projektia voi simuloida PC:ll\u00e4 ja ett\u00e4 k\u00e4ytt\u00f6liittym\u00e4n voi n\u00e4ytt\u00e4\u00e4 usealla kielell\u00e4.<\/p>\n<ul>\n<li><b>H\u00e4lytykset<\/b> \u2013 prioriteetit, kuittaus ja h\u00e4lytyshistoria. ISA-18.2:een perustuva IEC 62682 kuvaa, miten h\u00e4lytysten hallinta suunnitellaan niin, etteiv\u00e4t k\u00e4ytt\u00e4j\u00e4t huku h\u00e4lytyksiin.<\/li>\n<li><b>Reseptit<\/b> \u2013 eri tuotteiden parametrit tallennetaan paneeliin ja l\u00e4hetet\u00e4\u00e4n PLC:lle tuotevaihdon yhteydess\u00e4.<\/li>\n<li><b>Lokitus ja trendit<\/b> \u2013 arvot tallennetaan SD-kortille, USB-muistiin tai tietokantaan. L\u00e4\u00e4keteollisuudessa FDA 21 CFR Part 11 edellytt\u00e4\u00e4 p\u00e4\u00e4synhallintaa ja kirjausketjua (audit trail).<\/li>\n<li><b>Prosessigrafiikka<\/b> \u2013 ISA-101 antaa ohjeet selkeisiin n\u00e4ytt\u00f6ihin: pohjana neutraalit v\u00e4rit ja voimakkaat v\u00e4rit vain poikkeamille.<\/li>\n<\/ul>\n<h2>Et\u00e4yhteys ja tietoturva<\/h2>\n<p>Et\u00e4yhteyden avulla koneenrakentaja voi tehd\u00e4 vianetsint\u00e4\u00e4 ja p\u00e4ivitt\u00e4\u00e4 ohjelmaa matkustamatta asiakkaan luo. Osassa paneeleista on sis\u00e4\u00e4nrakennettu et\u00e4palvelu, toiset kytket\u00e4\u00e4n VPN-reitittimen kautta. Peruss\u00e4\u00e4nn\u00f6t ovat samat:<\/p>\n<ul>\n<li>\u00c4l\u00e4 koskaan avaa palomuuriin porttia suoraan paneeliin. K\u00e4yt\u00e4 salattua VPN-tunnelia.<\/li>\n<li>K\u00e4yt\u00e4 henkil\u00f6kohtaisia k\u00e4ytt\u00e4j\u00e4tunnuksia ja kaksivaiheista tunnistautumista ja vaihda kaikki oletussalasanat.<\/li>\n<li>Pid\u00e4 koneverkko erill\u00e4\u00e4n toimistoverkosta.<\/li>\n<li>Anna asiakkaan p\u00e4\u00e4tt\u00e4\u00e4, milloin et\u00e4yhteys on k\u00e4yt\u00f6ss\u00e4, ja kirjaa, kuka on ottanut yhteyden.<\/li>\n<\/ul>\n<p>IEC 62443:n ja NIS2:n vaatimuksia k\u00e4sitell\u00e4\u00e4n erillisess\u00e4 teollisuusverkkojen kyberturvallisuutta koskevassa oppaassamme.<\/p>\n<h2>Asennus ja liikkuvat n\u00e4yt\u00f6t<\/h2>\n<p>HMI-paneeli asennetaan yleens\u00e4 kaapin oven aukkoon, ja sen etupuoli on IP65- tai IP66-luokiteltu. Kun k\u00e4ytt\u00e4j\u00e4n on liikuttava koneen ymp\u00e4rill\u00e4, k\u00e4ytet\u00e4\u00e4n k\u00e4sipaneeleja, joissa on h\u00e4t\u00e4seis ja kolmiasentoinen hyv\u00e4ksynt\u00e4kytkin ja jotka liitet\u00e4\u00e4n liit\u00e4nt\u00e4rasian kautta.<\/p>\n<p>Nostureissa, mets\u00e4- ja kaivoskoneissa ja trukeissa k\u00e4ytet\u00e4\u00e4n kest\u00e4vi\u00e4 n\u00e4ytt\u00f6j\u00e4, joissa on CAN ja protokollat kuten SAE J1939 tai CANopen, 12 tai 24 V:n sy\u00f6tt\u00f6 ja E-merkint\u00e4. N\u00e4yt\u00f6n on oltava luettavissa auringonvalossa ja himmennytt\u00e4v\u00e4 y\u00f6ll\u00e4. Fyysiset painikkeet ovat plussaa, kun kuljettajalla on k\u00e4sineet tai kone t\u00e4risee.<\/p>\n<h2>Viisi yleist\u00e4 virhett\u00e4<\/h2>\n<ol class=\"g-pit\">\n<li><b>H\u00e4t\u00e4seis kosketusn\u00e4yt\u00f6ll\u00e4.<\/b> Turvatoiminnot on johdotettava turvapiiriin, ei koskaan painikkeeksi HMI-ohjelmistoon.<\/li>\n<li><b>Ajuri tarkistetaan liian my\u00f6h\u00e4\u00e4n.<\/b> Paneeli, jossa ei ole ajuria PLC:llesi, on kallis yll\u00e4tys k\u00e4ytt\u00f6\u00f6notossa.<\/li>\n<li><b>Liikaa h\u00e4lytyksi\u00e4.<\/b> Kun kaikki h\u00e4lytt\u00e4\u00e4, k\u00e4ytt\u00e4j\u00e4t lakkaavat lukemasta. Poista h\u00e4lytykset, jotka eiv\u00e4t vaadi toimenpiteit\u00e4.<\/li>\n<li><b>Avoin portti internetiin.<\/b> Porttiohjaus suoraan paneeliin on yleinen hy\u00f6kk\u00e4\u00e4jien sis\u00e4\u00e4np\u00e4\u00e4sytie.<\/li>\n<li><b>Projektitiedosto puuttuu.<\/b> Ilman l\u00e4hdetiedostoa ja salasanoja paneelia ei voi muuttaa eik\u00e4 vaihtaa. Pid\u00e4 projekti versionhallinnassa.<\/li>\n<\/ol>\n<h2>SCN:n k\u00e4ytt\u00f6paneelit<\/h2>\n<p>Toimitamme Yaskawan ja Weintekin k\u00e4ytt\u00f6paneeleja \u2013 4,3 tuuman paneeleista 21,5 tuuman Full HD -malleihin, k\u00e4sik\u00e4ytt\u00f6isi\u00e4 HMI-paneeleja ja n\u00e4yt\u00f6tt\u00f6mi\u00e4 HMI-palvelimia DIN-kiskoon. Ajoneuvoihin ja liikkuviin koneisiin on kest\u00e4vi\u00e4 n\u00e4ytt\u00f6j\u00e4 ja paneeli-PC:it\u00e4 muun muassa Winmatelta.<\/p>\n<h3>Esimerkkej\u00e4 valikoimastamme<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/ha1-71a41-0-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/HA1-71A41-0.jpg\" alt=\"Yaskawa TP310-SM\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Yaskawa<\/span><span class=\"g-pn\">TP310-SM<\/span><span class=\"g-pw\">10,1 tuuman k\u00e4ytt\u00f6paneeli, jossa IP66-etupuoli, Movicon CE sek\u00e4 RS-232\/422\/485 ja Ethernet PLC-liit\u00e4nt\u00e4\u00e4n.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/cmt3072xp-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/weintek-cmt3072xp-main.webp\" alt=\"Weintek cMT3072XP 7 tuuman kapasitiivinen HMI-paneeli\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Weintek<\/span><span class=\"g-pn\">cMT3072XP 7 tuuman kapasitiivinen HMI-paneeli<\/span><span class=\"g-pw\">7 tuuman HMI, jossa kapasitiivinen kosketus karkaistun lasin takana, IP66-etupuoli ja CAN, jossa CANopen ja SAE J1939.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/fm10-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/FM10.jpg\" alt=\"Winmate FM10 \u2013 10 tuuman ajoneuvotietokone, IP65-luokitus\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Winmate<\/span><span class=\"g-pn\">FM10 \u2013 10 tuuman ajoneuvotietokone, IP65-luokitus<\/span><span class=\"g-pw\">Kest\u00e4v\u00e4 10 tuuman ajoneuvotietokone, IP65, CAN ja \u221230\u202660 \u00b0C, trukkeihin, varastoihin ja mets\u00e4koneisiin.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/control-systems-fi\/hmi-fi\/\">Teolliset HMI- ja k\u00e4ytt\u00f6paneelit<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/control-systems-fi\/hmi-fi\/hmi-panels-fi\/\">HMI-paneelit<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/control-systems-fi\/plc-systems-fi\/\">PLC-j\u00e4rjestelm\u00e4t<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/industrial-computers-fi\/panel-pc-fi\/\">Paneeli-PC<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/industrial-computers-fi\/panel-pc-fi\/vehicle-panel-pc-fi\/\">Ajoneuvojen paneeli-PC:t<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/vpn-routers-fi\/\">VPN-reitittimet<\/a><\/div>\n<div class=\"g-cta\">\n<p>Haluatko tiet\u00e4\u00e4, mik\u00e4 paneeli sopii PLC:llesi ja ymp\u00e4rist\u00f6\u00f6si? Kysy insin\u00f6\u00f6rilt\u00e4mme \u2013 saat vastauksen 24 tunnin kuluessa.<\/p>\n<p><a href=\"https:\/\/scn.eu\/fi\/yhteystiedot\/\">Kysy insin\u00f6\u00f6rilt\u00e4<\/a><\/div>\n<h2>Usein kysytty\u00e4<\/h2>\n<details>\n<summary>Mit\u00e4 HMI tarkoittaa?<\/summary>\n<p>Human Machine Interface eli ihmisen ja koneen v\u00e4linen k\u00e4ytt\u00f6liittym\u00e4. Yleens\u00e4 kosketusn\u00e4ytt\u00f6, jolla k\u00e4ytt\u00e4j\u00e4 n\u00e4kee tilan, muuttaa asetuksia ja kuittaa h\u00e4lytyksi\u00e4.<\/p>\n<\/details>\n<details>\n<summary>Mik\u00e4 ero on HMI:ll\u00e4 ja SCADAlla?<\/summary>\n<p>HMI on yleens\u00e4 yhden koneen paikallinen paneeli. SCADA on ylemm\u00e4n tason j\u00e4rjestelm\u00e4, joka ker\u00e4\u00e4 dataa monista koneista tai asemista ja sis\u00e4lt\u00e4\u00e4 h\u00e4lytysten hallinnan, historian ja raportit.<\/p>\n<\/details>\n<details>\n<summary>Toimiiko HMI-paneeli Siemensin PLC:n kanssa?<\/summary>\n<p>Kyll\u00e4, useimmissa HMI-paneeleissa on ajurit Siemens S7:lle. S7-1200:ssa ja S7-1500:ssa voi olla tarpeen ottaa PUT\/GET k\u00e4ytt\u00f6\u00f6n tai k\u00e4ytt\u00e4\u00e4 optimoimattomia datablokkeja paneelin ajurista riippuen.<\/p>\n<\/details>\n<details>\n<summary>Miten HMI:hin saa turvallisen et\u00e4yhteyden?<\/summary>\n<p>K\u00e4yt\u00e4 salattua VPN-tunnelia, henkil\u00f6kohtaisia k\u00e4ytt\u00e4j\u00e4tunnuksia ja kaksivaiheista tunnistautumista. \u00c4l\u00e4 koskaan avaa portteja suoraan paneeliin, ja anna asiakkaan p\u00e4\u00e4tt\u00e4\u00e4, milloin yhteys on k\u00e4yt\u00f6ss\u00e4.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>K\u00e4ytt\u00f6paneeli on se osa konetta, jonka k\u00e4ytt\u00e4j\u00e4 n\u00e4kee. T\u00e4ss\u00e4 oppaassa kerrotaan HMI-paneelin ja paneeli-PC:n erot, miten paneeli kommunikoi PLC:n kanssa ja mit\u00e4 ohjelmistossa, h\u00e4lytyksiss\u00e4 ja et\u00e4yhteyksiss\u00e4 kannattaa huomioida.<\/p>\n","protected":false},"author":11,"featured_media":8235372,"template":"","meta":{"_yoast_wpseo_focuskw":"hmi-paneeli","_yoast_wpseo_metadesc":"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[887,888],"_scn_guide_sectors":[1011],"_scn_guide_type":"tech","_scn_guide_order":45,"footnotes":""},"class_list":["post-8235434","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean | SCN<\/title>\n<meta name=\"description\" content=\"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/\" \/>\n<meta property=\"og:locale\" content=\"fi_FI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean | SCN\" \/>\n<meta property=\"og:description\" content=\"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:32:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-hmi-f1-fi.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"544\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Arvioitu lukuaika\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuuttia\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/\",\"name\":\"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-hmi-f1-fi.webp\",\"datePublished\":\"2026-10-24T17:32:03+00:00\",\"dateModified\":\"2026-10-24T17:32:05+00:00\",\"description\":\"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/#breadcrumb\"},\"inLanguage\":\"fi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-hmi-f1-fi.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-hmi-f1-fi.webp\",\"width\":1520,\"height\":544,\"caption\":\"HMI-paneeli lukee ja kirjoittaa PLC:n tageja, l\u00e4hett\u00e4\u00e4 dataa SCADAan OPC UA:n kautta ja on et\u00e4k\u00e4ytett\u00e4viss\u00e4 VPN-reitittimen kautta\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/hmi-paneeli\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/fi\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fi\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean | SCN","description":"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/","og_locale":"fi_FI","og_type":"article","og_title":"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean | SCN","og_description":"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.","og_url":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:32:05+00:00","og_image":[{"width":1520,"height":544,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-hmi-f1-fi.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Arvioitu lukuaika":"6 minuuttia"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/","url":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/","name":"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/fi\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-hmi-f1-fi.webp","datePublished":"2026-10-24T17:32:03+00:00","dateModified":"2026-10-24T17:32:05+00:00","description":"N\u00e4in valitset HMI-paneelin: HMI-paneeli vai paneeli-PC ja SCADA, ajurit Siemensille, Rockwellille ja Modbusille, h\u00e4lytykset, reseptit ja et\u00e4yhteys.","breadcrumb":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/#breadcrumb"},"inLanguage":"fi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/"]}]},{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-hmi-f1-fi.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-hmi-f1-fi.webp","width":1520,"height":544,"caption":"HMI-paneeli lukee ja kirjoittaa PLC:n tageja, l\u00e4hett\u00e4\u00e4 dataa SCADAan OPC UA:n kautta ja on et\u00e4k\u00e4ytett\u00e4viss\u00e4 VPN-reitittimen kautta"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/fi\/oppaat\/hmi-paneeli\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/fi\/"},{"@type":"ListItem","position":2,"name":"HMI-paneeli ja k\u00e4ytt\u00f6paneelit \u2013 n\u00e4in valitset oikean"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/fi\/#website","url":"https:\/\/scn.eu\/fi\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/fi\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/fi\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fi"},{"@type":"Organization","@id":"https:\/\/scn.eu\/fi\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/fi\/","logo":{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/scn.eu\/fi\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/fi\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8235434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8235434\/revisions"}],"predecessor-version":[{"id":8235511,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8235434\/revisions\/8235511"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/media\/8235372"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/media?parent=8235434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}