{"id":8234605,"date":"2026-10-24T17:30:18","date_gmt":"2026-10-24T17:30:18","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234605"},"modified":"2026-10-24T17:30:39","modified_gmt":"2026-10-24T17:30:39","slug":"paineanturit","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/","title":{"rendered":"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset<\/h1>\n<p class=\"g-lead\">Paineanturi muuttaa \u00f6ljyn, ilman, veden tai kaasun paineen s\u00e4hk\u00f6iseksi signaaliksi. T\u00e4ss\u00e4 oppaassa kerrotaan, miten painemuunnin, painel\u00e4hetin ja painekytkin eroavat toisistaan, mit\u00e4 tarkkuus oikeastaan sis\u00e4lt\u00e4\u00e4 ja miten v\u00e4lt\u00e4t yleisimm\u00e4t virheet.<\/p>\n<div class=\"g-short\"><b class=\"t\">Lyhyesti<\/b><\/p>\n<ul>\n<li><b>Vertailupaine<\/b> \u2013 p\u00e4\u00e4t\u00e4 ensin, mihin painetta verrataan: ymp\u00e4r\u00f6iv\u00e4\u00e4n ilmaan (ylipaine), tyhji\u00f6\u00f6n (absoluuttinen paine) vai toiseen paineeseen (paine-ero).<\/li>\n<li><b>L\u00e4hetin vai kytkin<\/b> \u2013 l\u00e4hetin antaa mittaussignaalin, kuten 4\u201320 mA, 0\u201310 V tai CAN. Painekytkin vain vaihtaa koskettimen tilaa asetetussa paineessa.<\/li>\n<li><b>Mittausalue<\/b> \u2013 nyrkkis\u00e4\u00e4nt\u00f6n\u00e4 normaalin k\u00e4ytt\u00f6paineen kannattaa olla 50\u201375 % mittausalueesta. Tarkista my\u00f6s ylikuormituspaine paineiskujen varalta.<\/li>\n<li><b>Tarkkuus<\/b> \u2013 vertaa kokonaisvirhett\u00e4 koko l\u00e4mp\u00f6tila-alueella, \u00e4l\u00e4 pelkk\u00e4\u00e4 lineaarisuutta huoneenl\u00e4mm\u00f6ss\u00e4.<\/li>\n<li><b>Materiaalit<\/b> \u2013 v\u00e4liaine ratkaisee: ruostumaton ter\u00e4s, keraami tai muovi sek\u00e4 tiiviste, joka kest\u00e4\u00e4 kyseist\u00e4 nestett\u00e4 tai kaasua.<\/li>\n<\/ul>\n<\/div>\n<h2>Ylipaine, absoluuttinen paine vai paine-ero?<\/h2>\n<p>Kaikki paine mitataan jotakin vertailupainetta vastaan. <b>Ylipaine<\/b> mitataan ymp\u00e4r\u00f6iv\u00e4\u00e4 ilmanpainetta vastaan \u2013 sen n\u00e4et esimerkiksi hydraulij\u00e4rjestelm\u00e4n tai paineilmaverkon painemittarista. <b>Absoluuttinen paine<\/b> mitataan tyhji\u00f6t\u00e4 vastaan, ja sit\u00e4 k\u00e4ytet\u00e4\u00e4n silloin, kun ilmanpaineen vaihtelu ei saa vaikuttaa lukemaan, kuten tyhji\u00f6prosesseissa, barometrisessa mittauksessa ja kaasujen sekoituksessa. <b>Paine-ero<\/b> on kahden liit\u00e4nn\u00e4n v\u00e4linen erotus, esimerkiksi suodattimen tai puhaltimen yli tai virtausmittauksen mittalaipan yli.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f1-fi.webp\" alt=\"Kolme mittauskennoa: ylipaine mitataan ymp\u00e4r\u00f6iv\u00e4\u00e4 ilmaa vastaan, absoluuttinen paine tyhji\u00f6t\u00e4 vastaan ja paine-ero kahden liit\u00e4nn\u00e4n v\u00e4lill\u00e4\" width=\"1520\" height=\"500\" loading=\"lazy\" decoding=\"async\"><figcaption>Vertailupaine ratkaisee, mit\u00e4 anturi mittaa: ymp\u00e4r\u00f6iv\u00e4\u00e4 ilmaa, tyhji\u00f6t\u00e4 vai toista painetta vastaan.<\/figcaption><\/figure>\n<div class=\"g-short\">\n<p style=\"margin:0\">Yksik\u00f6t: 1 bar = 100 kPa = 0,1 MPa, ja 1 psi on noin 69 mbar. Yhdysvaltalaisissa datalehdiss\u00e4 k\u00e4ytet\u00e4\u00e4n merkint\u00f6j\u00e4 psig (ylipaine), psia (absoluuttinen paine) ja psid (paine-ero).<\/p>\n<\/div>\n<h2>Painemuunnin, painel\u00e4hetin vai painekytkin \u2013 mit\u00e4 eroa niill\u00e4 on?<\/h2>\n<ul>\n<li><b>Painemuunnin eli transducer<\/b> \u2013 pelkk\u00e4 mittauskenno yksinkertaisella signaalilla, usein muutama millivoltti sy\u00f6tt\u00f6j\u00e4nnitteen volttia kohden (mV\/V). Signaali t\u00e4ytyy vahvistaa ennen k\u00e4ytt\u00f6\u00e4.<\/li>\n<li><b>Painel\u00e4hetin<\/b> \u2013 anturi, jossa on sis\u00e4\u00e4nrakennettu elektroniikka ja standardil\u00e4ht\u00f6. T\u00e4t\u00e4 useimmat tarkoittavat nyky\u00e4\u00e4n paineanturilla.<\/li>\n<li><b>Painekytkin<\/b> \u2013 vaihtaa koskettimen tilaa, kun paine ohittaa asetusarvon. Mekaaniset kytkimet eiv\u00e4t tarvitse k\u00e4ytt\u00f6j\u00e4nnitett\u00e4, elektronisissa on usein lis\u00e4ksi analoginen l\u00e4ht\u00f6.<\/li>\n<\/ul>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f2-fi.webp\" alt=\"Lohkokaavio: painemuunnin antaa heikon millivolttisignaalin, painel\u00e4hettimen elektroniikka antaa standardisignaalin ja painekytkin vaihtaa koskettimen tilaa asetusarvossa\" width=\"1520\" height=\"472\" loading=\"lazy\" decoding=\"async\"><figcaption>Sama mittauskenno voi olla painemuuntimessa, painel\u00e4hettimess\u00e4 tai painekytkimess\u00e4. Elektroniikka ratkaisee signaalin.<\/figcaption><\/figure>\n<p>Valitse kytkin, kun sinun tarvitsee tiet\u00e4\u00e4 vain, onko paine liian korkea tai liian matala \u2013 esimerkiksi liian matala \u00f6ljynpaine, tukkeutunut suodatin tai paineilman lasku. Valitse l\u00e4hetin, kun ohjausj\u00e4rjestelm\u00e4n t\u00e4ytyy s\u00e4\u00e4t\u00e4\u00e4, tallentaa tai h\u00e4lytt\u00e4\u00e4 useammalla eri tasolla. Turvallisuustoimintoihin on saatavana kytkimi\u00e4, jotka on arvioitu standardien IEC 61508 (SIL) ja ISO 13849 (PL) mukaan.<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>L\u00e4ht\u00f6<\/th>\n<th>Etu<\/th>\n<th>Huomioitavaa<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">4\u201320 mA<\/td>\n<td>Siet\u00e4\u00e4 pitki\u00e4 kaapeleita ja h\u00e4iri\u00f6it\u00e4. Johdinkatko n\u00e4kyy heti, koska nollakohta on 4 mA.<\/td>\n<td>Sy\u00f6tt\u00f6 tulee usein samoja kahta johdinta pitkin. Tarkista kuormaresistanssi.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">0\u201310 V<\/td>\n<td>Helppo lukea ohjaukseen.<\/td>\n<td>Herkk\u00e4 h\u00e4iri\u00f6ille ja j\u00e4nniteh\u00e4vi\u00f6lle pitkiss\u00e4 kaapeleissa.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Ratiometrinen<\/td>\n<td>Yleinen ajoneuvoissa. Signaali on osuus sy\u00f6tt\u00f6j\u00e4nnitteest\u00e4, esim. 10\u201390 %.<\/td>\n<td>Ohjaimen t\u00e4ytyy k\u00e4ytt\u00e4\u00e4 samaa sy\u00f6tt\u00f6j\u00e4nnitett\u00e4 referenssin\u00e4.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">CANopen, SAE J1939<\/td>\n<td>Monta anturia samassa v\u00e4yl\u00e4ss\u00e4, diagnostiikka mukana.<\/td>\n<td>Aseta osoite ja v\u00e4yl\u00e4n p\u00e4\u00e4tevastus oikein.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">IO-Link<\/td>\n<td>Asetukset ja diagnostiikka tavallisen anturikaapelin kautta (IEC 61131-9).<\/td>\n<td>Vaatii IO-Link-masterin.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Mittausalue, ylikuormitus ja paineiskut<\/h2>\n<p>Mittausalueen t\u00e4ytyy kattaa normaali k\u00e4ytt\u00f6paine riitt\u00e4v\u00e4ll\u00e4 marginaalilla. Liian suuri mittausalue kasvattaa virhett\u00e4 baareina, koska virhe ilmoitetaan prosentteina t\u00e4ydest\u00e4 mittausalueesta (FS). \u00b10,5 % FS on 600 barin anturissa \u00b13 bar, vaikka mittaisit vain 20 baria.<\/p>\n<p>Datalehdess\u00e4 ilmoitetaan my\u00f6s <b>ylikuormituspaine<\/b>, jonka anturi kest\u00e4\u00e4 ilman pysyv\u00e4\u00e4 muutosta, sek\u00e4 <b>murtopaine<\/b>, jossa anturi rikkoutuu. N\u00e4iden v\u00e4liss\u00e4 anturin nollapiste voi siirty\u00e4 pysyv\u00e4sti.<\/p>\n<p>Paineiskut ovat yleinen syy anturivikoihin hydrauliikassa ja vesij\u00e4rjestelmiss\u00e4. Kun venttiili sulkeutuu nopeasti, paine voi nousta muutamaksi millisekunniksi moninkertaiseksi normaaliin verrattuna \u2013 liian nopeasti, jotta sen n\u00e4kisi painemittarista. Anturin liit\u00e4nt\u00e4\u00e4n asennettava kuristin (snubber) vaimentaa piikki\u00e4. Kavitaatio, jossa h\u00f6yrykuplat luhistuvat, aiheuttaa sek\u00e4 paineiskuja ett\u00e4 eroosiota. \u00c4l\u00e4 sijoita anturia heti pumpun, venttiilin tai kuristuksen j\u00e4lkeen.<\/p>\n<h2>Mit\u00e4 tarkkuus sis\u00e4lt\u00e4\u00e4?<\/h2>\n<p>Kaksi anturia, joiden datalehdess\u00e4 lukee 0,25 %, voivat k\u00e4yt\u00e4nn\u00f6ss\u00e4 erota paljonkin. Tarkista, mit\u00e4 luku kattaa:<\/p>\n<ul>\n<li><b>Lineaarisuus<\/b> \u2013 poikkeama suorasta viivasta. Jos se ilmoitetaan BFSL-menetelm\u00e4ll\u00e4 (best fit straight line), luku on pienempi kuin nollasta t\u00e4yteen mittausalueeseen mitattuna.<\/li>\n<li><b>Hystereesi<\/b> \u2013 signaalin ero samassa paineessa, kun paine nousee ja kun se laskee.<\/li>\n<li><b>Toistettavuus<\/b> \u2013 kuinka hyvin toistetut mittaukset vastaavat toisiaan.<\/li>\n<li><b>L\u00e4mp\u00f6tilavirhe<\/b> \u2013 kuinka nollapiste ja herkkyys muuttuvat l\u00e4mp\u00f6tilan mukana. Usein suurin virhel\u00e4hde ulkona ja liikkuvissa ty\u00f6koneissa.<\/li>\n<li><b>Pitk\u00e4aikaisstabiilius<\/b> \u2013 kuinka paljon anturi ry\u00f6mii vuodessa.<\/li>\n<\/ul>\n<p>Hy\u00f6dyllisin luku on <b>kokonaisvirhe (total error band)<\/b> koko kompensoidulla l\u00e4mp\u00f6tila-alueella. Se yhdist\u00e4\u00e4 kaikki edell\u00e4 mainitut tekij\u00e4t ja kertoo, kuinka paljon lukema voi todellisuudessa poiketa.<\/p>\n<h2>V\u00e4liaine, materiaalit ja asennus<\/h2>\n<p>Kaikkien v\u00e4liaineen kanssa kosketuksissa olevien osien t\u00e4ytyy kest\u00e4\u00e4 v\u00e4liainetta. Ruostumaton ter\u00e4s 316L soveltuu useimmille \u00f6ljyille, vedelle ja kaasuille. Keraamiset kennot kest\u00e4v\u00e4t monia aggressiivisia v\u00e4liaineita, ja eritt\u00e4in puhtaisiin prosesseihin ja vahvoille hapoille on saatavana kytkimi\u00e4, joiden kostuvat osat ovat PFA:ta ja PTFE:t\u00e4. Tarkista my\u00f6s tiiviste: FKM, EPDM ja NBR sopivat eri nesteille, ja t\u00e4ysin hitsatuissa antureissa tiivistett\u00e4 ei ole lainkaan.<\/p>\n<ol class=\"g-pit\">\n<li><b>V\u00e4\u00e4r\u00e4 paikka putkessa.<\/b> Nesteill\u00e4 anturi asennetaan putken kylkeen, jotta kalvolle ei kerry ilmaa eik\u00e4 sinne laskeudu sakkaa. Kaasuilla anturi asennetaan putken p\u00e4\u00e4lle, jotta kondenssivesi valuu pois.<\/li>\n<li><b>Tukkeutunut tuuletus.<\/b> Ylipaineanturi tarvitsee yhteyden ymp\u00e4r\u00f6iv\u00e4\u00e4n ilmaan kaapelin tai tuuletusaukon kautta. Jos maali tai vesi tukkii sen, lukema alkaa seurata ilmanpainetta ja l\u00e4mp\u00f6tilaa.<\/li>\n<li><b>Kuuma h\u00f6yry suoraan anturiin.<\/b> Sifoni tai j\u00e4\u00e4hdytysputki suojaa anturia h\u00f6yrylt\u00e4 ja v\u00e4liaineilta, jotka ovat kuumempia kuin datalehti sallii.<\/li>\n<li><b>Liian tiukalle kiristetty liitin.<\/b> Liian tiukalle kiristetty kierre voi v\u00e4\u00e4nt\u00e4\u00e4 runkoa ja siirt\u00e4\u00e4 nollapistett\u00e4, varsinkin matalan paineen antureissa. Noudata ilmoitettua kiristysmomenttia.<\/li>\n<\/ol>\n<h2>Miss\u00e4 paineantureita ja painekytkimi\u00e4 k\u00e4ytet\u00e4\u00e4n?<\/h2>\n<ul>\n<li><b>Liikkuvat ty\u00f6koneet<\/b> \u2013 hydraulipaine nostureissa, mets\u00e4koneissa ja py\u00f6r\u00e4kuormaajissa kuormanlaskentaan, ylikuormitussuojaukseen ja ohjaukseen.<\/li>\n<li><b>Tehtaat<\/b> \u2013 paineilma, voitelu, j\u00e4\u00e4hdytysvesi ja hydrauliset puristimet. Painekytkin pys\u00e4ytt\u00e4\u00e4 koneen, kun \u00f6ljynpaine laskee liian matalaksi.<\/li>\n<li><b>Energia ja vesi<\/b> \u2013 kaukol\u00e4mp\u00f6, l\u00e4mp\u00f6pumput, pumppaamot ja vesivoimaloiden hydrauliikka.<\/li>\n<li><b>Muovi- ja elintarviketeollisuus<\/b> \u2013 sulapaine ekstrudereissa ja ruiskuvalukoneissa sek\u00e4 hygieeniset anturit pesua kest\u00e4viin kohteisiin.<\/li>\n<li><b>Ilmailu ja puolustus<\/b> \u2013 hitsatut, hermeettisesti suljetut anturit ja kytkimet lennonohjaukseen, jarruihin ja laskutelineisiin.<\/li>\n<\/ul>\n<h2>Paineanturit ja painekytkimet SCN:lt\u00e4<\/h2>\n<p>Valikoimaamme kuuluu Huba Controlin painel\u00e4hettimi\u00e4 liikkuvan kaluston hydrauliikkaan sek\u00e4 Precision Sensorsin, Sensatan ja Nominal Controlsin antureita ja kytkimi\u00e4 eritt\u00e4in puhtaille kaasuille, ilmailuun ja prosessiteollisuuteen. Kerro meille v\u00e4liaine, paine, signaali ja k\u00e4ytt\u00f6ymp\u00e4rist\u00f6, niin autamme sinua valitsemaan.<\/p>\n<h3>Esimerkkej\u00e4 valikoimastamme<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/604-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/pic_604.jpg\" alt=\"Huba Control 604 paine-erokytkin\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Huba Control<\/span><span class=\"g-pn\">604 paine-erokytkin<\/span><span class=\"g-pw\">Paine-erokytkin ilmanvaihtoon: valvoo suodattimia ja puhaltimia ja suojaa l\u00e4mmityspattereita ylikuumenemiselta.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/staset-sil-3-pressure-switch-transducer-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/precision-sensors-staset-main.webp\" alt=\"Precision Sensors Staset SIL 3 -painekytkin ja paineanturi\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Precision Sensors<\/span><span class=\"g-pn\">Staset SIL 3 -painekytkin ja paineanturi<\/span><span class=\"g-pw\">Kytkin, paineanturi ja n\u00e4ytt\u00f6 samassa yksik\u00f6ss\u00e4. Kytkinl\u00e4ht\u00f6 soveltuu SIL 3 -tasolle (IEC 61508) ja PL e -tasolle (ISO 13849).<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/px500-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/PX500.png\" alt=\"Sensata PX500 painel\u00e4hetin\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Sensata<\/span><span class=\"g-pn\">PX500 painel\u00e4hetin<\/span><span class=\"g-pw\">Sensatan paineanturi l\u00e4mp\u00f6tila-alueelle \u221255\u2026150 \u00b0C.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/sensors-fi\/pressure-sensors\/\">Paineanturit ja painel\u00e4hettimet<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/sensors-fi\/pressure-sensors\/pressure-sensors-mobile\/\">Paineanturit \u2013 liikkuvat ty\u00f6koneet<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/sensors-fi\/pressure-sensors\/pressure-switches-fi\/\">Painekytkimet<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/can-interfaces-fi\/\">CAN-liit\u00e4nn\u00e4t<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/connectors-and-cables-fi\/\">Liittimet ja kaapelit<\/a><\/div>\n<div class=\"g-cta\">\n<p>Etk\u00f6 ole varma mittausalueesta, signaalista tai materiaaleista? Kysy insin\u00f6\u00f6reilt\u00e4mme \u2013 saat vastauksen 24 tunnin kuluessa.<\/p>\n<p><a href=\"https:\/\/scn.eu\/fi\/yhteystiedot\/\">Kysy insin\u00f6\u00f6rilt\u00e4<\/a><\/div>\n<h2>Usein kysytyt kysymykset<\/h2>\n<details>\n<summary>Mit\u00e4 eroa on paineanturilla ja painel\u00e4hettimell\u00e4?<\/summary>\n<p>Painel\u00e4hettimess\u00e4 on sis\u00e4\u00e4nrakennettu elektroniikka, joka antaa standardisignaalin, kuten 4\u201320 mA. Painemuunnin eli transducer antaa tarkasti ottaen heikon millivolttisignaalin, joka t\u00e4ytyy vahvistaa. K\u00e4yt\u00e4nn\u00f6ss\u00e4 termej\u00e4 k\u00e4ytet\u00e4\u00e4n usein sekaisin.<\/p>\n<\/details>\n<details>\n<summary>Kumpi kannattaa valita, 4\u201320 mA vai 0\u201310 V?<\/summary>\n<p>4\u201320 mA siet\u00e4\u00e4 paremmin h\u00e4iri\u00f6it\u00e4 ja pitki\u00e4 kaapeleita, ja johdinkatko n\u00e4kyy heti, kun virta laskee alle 4 mA:n. 0\u201310 V toimii hyvin lyhyill\u00e4 et\u00e4isyyksill\u00e4 koneen tai s\u00e4hk\u00f6kaapin sis\u00e4ll\u00e4.<\/p>\n<\/details>\n<details>\n<summary>Miten valitsen mittausalueen?<\/summary>\n<p>Normaalin k\u00e4ytt\u00f6paineen kannattaa olla noin 50\u201375 % mittausalueesta, ja paineiskujen t\u00e4ytyy j\u00e4\u00e4d\u00e4 ylikuormituspaineen alapuolelle. Liian suuri mittausalue kasvattaa virhett\u00e4 baareina.<\/p>\n<\/details>\n<details>\n<summary>Miksi paineanturini ry\u00f6mii?<\/summary>\n<p>Tavallisia syit\u00e4 ovat ylikuormituspaineen ylitt\u00e4v\u00e4t paineiskut, l\u00e4mp\u00f6tilat kompensoidun alueen ulkopuolella, tukkeutunut tuuletus tai liian tiukalle kiristetty liitin.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Paineanturi muuttaa \u00f6ljyn, ilman, veden tai kaasun paineen s\u00e4hk\u00f6iseksi signaaliksi. T\u00e4ss\u00e4 oppaassa kerrotaan, miten painemuunnin, painel\u00e4hetin ja painekytkin eroavat toisistaan, mit\u00e4 tarkkuus oikeastaan sis\u00e4lt\u00e4\u00e4 ja miten v\u00e4lt\u00e4t yleisimm\u00e4t virheet.<\/p>\n","protected":false},"author":11,"featured_media":8234525,"template":"","meta":{"_yoast_wpseo_focuskw":"paineanturi","_yoast_wpseo_metadesc":"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[660,662,12221],"_scn_guide_sectors":[1011,1037],"_scn_guide_type":"tech","_scn_guide_order":30,"footnotes":""},"class_list":["post-8234605","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset | SCN<\/title>\n<meta name=\"description\" content=\"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/\" \/>\n<meta property=\"og:locale\" content=\"fi_FI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset | SCN\" \/>\n<meta property=\"og:description\" content=\"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:30:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f1-fi.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Arvioitu lukuaika\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuuttia\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/\",\"name\":\"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-tryck-f1-fi.webp\",\"datePublished\":\"2026-10-24T17:30:18+00:00\",\"dateModified\":\"2026-10-24T17:30:39+00:00\",\"description\":\"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/#breadcrumb\"},\"inLanguage\":\"fi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-tryck-f1-fi.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-tryck-f1-fi.webp\",\"width\":1520,\"height\":500,\"caption\":\"Kolme mittauskennoa: ylipaine mitataan ymp\u00e4r\u00f6iv\u00e4\u00e4 ilmaa vastaan, absoluuttinen paine tyhji\u00f6t\u00e4 vastaan ja paine-ero kahden liit\u00e4nn\u00e4n v\u00e4lill\u00e4\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/paineanturit\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/fi\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fi\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset | SCN","description":"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/","og_locale":"fi_FI","og_type":"article","og_title":"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset | SCN","og_description":"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.","og_url":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:30:39+00:00","og_image":[{"width":1520,"height":500,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f1-fi.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Arvioitu lukuaika":"6 minuuttia"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/","url":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/","name":"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/fi\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f1-fi.webp","datePublished":"2026-10-24T17:30:18+00:00","dateModified":"2026-10-24T17:30:39+00:00","description":"Paineanturi, painel\u00e4hetin vai painekytkin? N\u00e4in valitset vertailupaineen, mittausalueen, l\u00e4hd\u00f6n ja materiaalit ja v\u00e4lt\u00e4t paineiskut ja virheet.","breadcrumb":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/#breadcrumb"},"inLanguage":"fi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/"]}]},{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f1-fi.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-tryck-f1-fi.webp","width":1520,"height":500,"caption":"Kolme mittauskennoa: ylipaine mitataan ymp\u00e4r\u00f6iv\u00e4\u00e4 ilmaa vastaan, absoluuttinen paine tyhji\u00f6t\u00e4 vastaan ja paine-ero kahden liit\u00e4nn\u00e4n v\u00e4lill\u00e4"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/fi\/oppaat\/paineanturit\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/fi\/"},{"@type":"ListItem","position":2,"name":"Paineanturi, painel\u00e4hetin vai painekytkin \u2013 n\u00e4in valitset"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/fi\/#website","url":"https:\/\/scn.eu\/fi\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/fi\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/fi\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fi"},{"@type":"Organization","@id":"https:\/\/scn.eu\/fi\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/fi\/","logo":{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/scn.eu\/fi\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/fi\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8234605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8234605\/revisions"}],"predecessor-version":[{"id":8235097,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8234605\/revisions\/8235097"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/media\/8234525"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/media?parent=8234605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}