{"id":8234598,"date":"2026-10-24T17:26:33","date_gmt":"2026-10-24T17:26:33","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234598"},"modified":"2026-10-24T17:30:35","modified_gmt":"2026-10-24T17:30:35","slug":"teollisuuden-ethernet-protokollat","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/","title":{"rendered":"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus<\/h1>\n<p class=\"g-lead\">Logiikka puhuu PROFINETia, energiamittari Modbusia ja servok\u00e4ytt\u00f6 EtherCATia. T\u00e4ss\u00e4 oppaassa kerrotaan, mik\u00e4 erottaa yleisimm\u00e4t teollisuusprotokollat toisistaan, miss\u00e4 niit\u00e4 k\u00e4ytet\u00e4\u00e4n ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n, jotta ne saadaan keskustelemaan kesken\u00e4\u00e4n.<\/p>\n<div class=\"g-short\"><b class=\"t\">Lyhyesti<\/b><\/p>\n<ul>\n<li><b>PROFINET<\/b> \u2013 Siemens-maailma ja Euroopan yleisin valinta. Reaaliaikainen Ethernet I\/O:lle ja taajuusmuuttajille.<\/li>\n<li><b>EtherNet\/IP<\/b> \u2013 Rockwell (Allen-Bradley) ja Omron. Hallitseva Pohjois-Amerikassa.<\/li>\n<li><b>Modbus TCP\/RTU<\/b> \u2013 yksinkertainen ja avoin. L\u00f6ytyy l\u00e4hes kaikesta energiamittareista taajuusmuuttajiin.<\/li>\n<li><b>EtherCAT ja CAN<\/b> \u2013 EtherCAT nopeaan liikkeenohjaukseen, CANopen ja J1939 koneisiin ja ajoneuvoihin.<\/li>\n<li><b>OPC UA<\/b> \u2013 datalle, joka kulkee yl\u00f6sp\u00e4in SCADAan, MES-j\u00e4rjestelm\u00e4\u00e4n ja pilveen, ei nopealle I\/O:lle.<\/li>\n<li>Kun kaksi laitetta puhuu eri protokollaa, tarvitset <b>yhdysk\u00e4yt\u00e4v\u00e4n<\/b>. Yhteinen kaapeli ei riit\u00e4.<\/li>\n<\/ul>\n<\/div>\n<h2>Miksi protokollia on niin paljon?<\/h2>\n<p>1980-luvulta l\u00e4htien kentt\u00e4v\u00e4yl\u00e4t korvasivat paksut kaapelinipput logiikoiden ja antureiden v\u00e4lill\u00e4. Jokainen suuri valmistaja ajoi omaa standardiaan: Siemens tuki PROFIBUSia, Allen-Bradley DeviceNeti\u00e4 ja Bosch kehitti CAN-v\u00e4yl\u00e4n autoihin. Ethernetin my\u00f6t\u00e4 tulivat PROFINET, k\u00e4yt\u00e4nn\u00f6ss\u00e4 PROFIBUSin seuraaja, sek\u00e4 EtherNet\/IP, joka k\u00e4ytt\u00e4\u00e4 samaa sovelluskerrosta (CIP) kuin DeviceNet.<\/p>\n<p>Kaapelit voivat n\u00e4ytt\u00e4\u00e4 samanlaisilta, mutta laitteet puhuvat eri kieli\u00e4. Yleens\u00e4 logiikka ratkaisee: jos asiakas valitsee Siemensin, k\u00e4ytet\u00e4\u00e4n PROFINETia, jos Rockwellin, k\u00e4ytet\u00e4\u00e4n EtherNet\/IP:t\u00e4. Kaikki muu tarvitsee tulkin.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f1-fi.webp\" alt=\"Automaatiopyramidi ja tyypilliset protokollat: OPC UA ja MQTT SCADAn ja pilven suuntaan, PROFINET, EtherNet\/IP, EtherCAT ja Modbus TCP ohjaustasolla, IO-Link, Modbus RTU, CANopen ja PROFIBUS kentt\u00e4tasolla\" width=\"1520\" height=\"560\" loading=\"lazy\" decoding=\"async\"><figcaption>Eri tasoilla eri protokollat: reaaliaika l\u00e4hell\u00e4 konetta, data ja analytiikka ylemp\u00e4n\u00e4.<\/figcaption><\/figure>\n<h2>Yleisimm\u00e4t protokollat yhdell\u00e4 silm\u00e4yksell\u00e4<\/h2>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Protokolla<\/th>\n<th>Siirtotie<\/th>\n<th>Tyypillinen k\u00e4ytt\u00f6<\/th>\n<th>Yleinen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">PROFINET<\/td>\n<td>Ethernet<\/td>\n<td>I\/O, taajuusmuuttajat ja robottisolut. IRT-versio hoitaa synkronoidun liikkeenohjauksen.<\/td>\n<td>Siemens ja monet muut. Suurin Euroopassa.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">EtherNet\/IP<\/td>\n<td>Ethernet<\/td>\n<td>I\/O ja taajuusmuuttajat. Perustuu CIP:hen.<\/td>\n<td>Rockwell (Allen-Bradley) ja Omron. Suurin Pohjois-Amerikassa.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Modbus TCP<\/td>\n<td>Ethernet<\/td>\n<td>Yksinkertainen valvonta ja ohjaus: mittarit, taajuusmuuttajat, k\u00e4ytt\u00f6paneelit ja SCADA.<\/td>\n<td>L\u00e4hes kaikki valmistajat. Avoin vuodesta 1979.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Modbus RTU<\/td>\n<td>RS-485<\/td>\n<td>Kuten Modbus TCP mutta sarjamuotoinen, enint\u00e4\u00e4n 247 orjalaitetta samassa v\u00e4yl\u00e4ss\u00e4.<\/td>\n<td>Vanhemmat ja yksinkertaisemmat laitteet, energiamittaus.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">EtherCAT<\/td>\n<td>Ethernet<\/td>\n<td>Nopea liikkeenohjaus lyhyill\u00e4 kiertoajoilla.<\/td>\n<td>Beckhoff sek\u00e4 monet servo- ja I\/O-valmistajat.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">CANopen, J1939<\/td>\n<td>CAN<\/td>\n<td>Sulautetut j\u00e4rjestelm\u00e4t, liikkuvat ty\u00f6koneet ja ajoneuvot.<\/td>\n<td>CANopen koneissa, J1939 kuorma-autoissa ja ty\u00f6koneissa.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">PROFIBUS<\/td>\n<td>RS-485, MBP<\/td>\n<td>Olemassa olevat laitokset (DP) ja prosessiteollisuus (PA).<\/td>\n<td>Siemens. Korvautuu v\u00e4hitellen PROFINETilla.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">OPC UA<\/td>\n<td>Ethernet<\/td>\n<td>Data SCADAan, MES-j\u00e4rjestelm\u00e4\u00e4n ja pilveen, sis\u00e4\u00e4nrakennettu tietoturva.<\/td>\n<td>Valmistajariippumaton, IEC 62541.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">IO-Link<\/td>\n<td>Kolmijohtiminen kaapeli<\/td>\n<td>Anturit ja toimilaitteet parametroinnilla ja diagnostiikalla.<\/td>\n<td>Kaikki suuret anturivalmistajat, IEC 61131-9.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>PROFINET-laitteet tunnistetaan laitenimest\u00e4, ja ne kuvataan GSDML-tiedostolla, EtherNet\/IP-laitteet EDS-tiedostolla. Modbusissa t\u00e4llaista kuvausta ei ole, joten tarvitset valmistajan rekisterikartan. EtherCAT k\u00e4sittelee kehykset lennossa jokaisessa orjalaitteessa ja vaatii siksi laitteisiin oman laitteiston. IO-Link ei ole verkko vaan enint\u00e4\u00e4n 20 metrin pisteest\u00e4 pisteeseen -yhteys anturin ja IO-Link-masterin v\u00e4lill\u00e4, ja master puolestaan on kytketty kentt\u00e4v\u00e4yl\u00e4\u00e4n.<\/p>\n<h2>Miss\u00e4 mit\u00e4kin protokollaa k\u00e4ytet\u00e4\u00e4n?<\/h2>\n<p>Valinta riippuu toimialasta, alueesta ja jo asennetuista laitteista.<\/p>\n<ul>\n<li><b>Tehtaat ja konevalmistajat<\/b> \u2013 PROFINET tai EtherNet\/IP asiakkaan logiikan mukaan. Sek\u00e4 Eurooppaan ett\u00e4 Yhdysvaltoihin myyt\u00e4v\u00e4 kone tarvitsee usein molemmat. Antureissa IO-Link yleistyy.<\/li>\n<li><b>Ajoneuvot ja liikkuvat ty\u00f6koneet<\/b> \u2013 CAN hallitsee. J1939 kuorma-autoissa, traktoreissa ja maanrakennuskoneissa, CANopen hisseiss\u00e4, trukeissa ja AGV-laitteissa.<\/li>\n<li><b>Energia ja s\u00e4hk\u00f6verkot<\/b> \u2013 Modbus energiamittareissa, inverttereiss\u00e4 ja akkuvarastoissa. S\u00e4hk\u00f6asemilla k\u00e4ytet\u00e4\u00e4n IEC 61850- ja IEC 60870-5-104-protokollia, jotka on usein k\u00e4\u00e4nnett\u00e4v\u00e4 Modbusiksi tai DNP3:ksi.<\/li>\n<li><b>Vesihuolto ja kiinteist\u00f6t<\/b> \u2013 Modbus RTU ja TCP SCADAn suuntaan. OPC UA ja MQTT, kun datan on kuljettava eteenp\u00e4in ylemm\u00e4n tason j\u00e4rjestelmiin.<\/li>\n<li><b>Raideliikenne<\/b> \u2013 omat junaprotokollat, kuten IEC 61375 -sarjan MVB, WTB ja TRDP, yhdysk\u00e4yt\u00e4vill\u00e4 Ethernetiin, sarjaliikenteeseen ja CAN-v\u00e4yl\u00e4\u00e4n.<\/li>\n<li><b>L\u00e4\u00e4kint\u00e4tekniikka ja laboratoriot<\/b> \u2013 CANopen ja sarjaliit\u00e4nn\u00e4t instrumenttien ja laitteiden sis\u00e4ll\u00e4.<\/li>\n<li><b>Puolijohteet ja elektroniikka<\/b> \u2013 SECS\/GEM tuotantolaitteiden ja tehtaan is\u00e4nt\u00e4j\u00e4rjestelm\u00e4n v\u00e4lill\u00e4.<\/li>\n<\/ul>\n<h2>Milloin tarvitset protokollayhdysk\u00e4yt\u00e4v\u00e4n?<\/h2>\n<p>Tarvitset sellaisen esimerkiksi silloin, kun Siemensin logiikan pit\u00e4\u00e4 lukea Modbus-mittaria. Yhdysk\u00e4yt\u00e4v\u00e4 on yleens\u00e4 toisella puolella master tai asiakas (client) ja toisella orja tai laite (device). Se ker\u00e4\u00e4 dataa syklisesti ja sijoittaa sen logiikan prosessikuvaan, joten ohjelma n\u00e4kee arvot tavallisina tuloina ja l\u00e4ht\u00f6in\u00e4.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f2-fi.webp\" alt=\"Yhdysk\u00e4yt\u00e4v\u00e4 kytkee PROFINET-logiikan kolmeen Modbus RTU -laitteeseen RS-485-v\u00e4yl\u00e4ss\u00e4: energiamittari, taajuusmuuttaja ja l\u00e4mp\u00f6tilas\u00e4\u00e4din\" width=\"1520\" height=\"480\" loading=\"lazy\" decoding=\"async\"><figcaption>Yhdysk\u00e4yt\u00e4v\u00e4 on logiikan suuntaan PROFINET-laite ja RS-485-v\u00e4yl\u00e4n laitteiden suuntaan Modbus-master.<\/figcaption><\/figure>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Jos sinun tarvitsee \u2026<\/th>\n<th>\u2026 valitse<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lukea Modbus-laitteita PROFINET-logiikalla<\/td>\n<td>Modbus\u2013PROFINET-yhdysk\u00e4yt\u00e4v\u00e4<\/td>\n<\/tr>\n<tr>\n<td>Kytke\u00e4 CANopen- tai J1939-kone Rockwellin logiikkaan<\/td>\n<td>CAN\u2013EtherNet\/IP-yhdysk\u00e4yt\u00e4v\u00e4<\/td>\n<\/tr>\n<tr>\n<td>Kytke\u00e4 Modbus- tai Ethernet-laitteita vanhempaan PROFIBUS-logiikkaan<\/td>\n<td>Yhdysk\u00e4yt\u00e4v\u00e4, jossa PROFIBUS-orja<\/td>\n<\/tr>\n<tr>\n<td>Lukea Modbus RTU -laitteita SCADAsta verkon yli<\/td>\n<td>Modbus RTU\u2013TCP-yhdysk\u00e4yt\u00e4v\u00e4<\/td>\n<\/tr>\n<tr>\n<td>L\u00e4hett\u00e4\u00e4 konedataa MES-j\u00e4rjestelm\u00e4\u00e4n tai pilveen<\/td>\n<td>IIoT-yhdysk\u00e4yt\u00e4v\u00e4, jossa OPC UA tai MQTT<\/td>\n<\/tr>\n<tr>\n<td>Kytke\u00e4 PC CAN-v\u00e4yl\u00e4\u00e4n testausta ja huoltoa varten<\/td>\n<td>USB- tai PCIe-CAN-liit\u00e4nt\u00e4<\/td>\n<\/tr>\n<tr>\n<td>Liitt\u00e4\u00e4 RS-232- tai RS-485-laitteita Ethernetiin protokollaa vaihtamatta<\/td>\n<td>Sarjaporttipalvelin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"g-short\">\n<p style=\"margin:0\">Yhdysk\u00e4yt\u00e4v\u00e4 sopii I\/O-datalle ja mittausarvoille, mutta ei synkronoidulle liikkeenohjaukselle. Siin\u00e4 taajuusmuuttajien ja logiikan pit\u00e4\u00e4 puhua samaa protokollaa.<\/p>\n<\/div>\n<h2>Yleisi\u00e4 virheit\u00e4<\/h2>\n<ol class=\"g-pit\">\n<li><b>Sama liitin ei tarkoita samaa protokollaa.<\/b> PROFINET- ja EtherNet\/IP-laitteet voivat jakaa kaapelit ja kytkimet, mutta ne eiv\u00e4t vaihda kesken\u00e4\u00e4n mit\u00e4\u00e4n dataa.<\/li>\n<li><b>Rekisterikartta puuttuu.<\/b> Modbus l\u00e4hett\u00e4\u00e4 vain 16-bittisi\u00e4 rekistereit\u00e4. Ilman valmistajan rekisterikarttaa et erota l\u00e4mp\u00f6tilaa tilatiedosta etk\u00e4 tied\u00e4, kumpi 32-bittisen arvon sana tulee ensin.<\/li>\n<li><b>Multicast tukkii verkon.<\/b> EtherNet\/IP l\u00e4hett\u00e4\u00e4 I\/O-dataa usein multicast-liikenteen\u00e4. Ilman kytkinten IGMP snooping -toimintoa liikenne menee jokaiseen porttiin ja voi ylikuormittaa yksinkertaisia laitteita.<\/li>\n<li><b>Liian pieni data-alue.<\/b> Se, montako tavua yhdysk\u00e4yt\u00e4v\u00e4 k\u00e4sittelee kumpaankin suuntaan ja kuinka nopeasti se p\u00e4ivitt\u00e4\u00e4, rajoittaa kytkett\u00e4vien laitteiden m\u00e4\u00e4r\u00e4\u00e4.<\/li>\n<li><b>V\u00e4\u00e4r\u00e4 protokolla teht\u00e4v\u00e4\u00e4n.<\/b> OPC UA sopii erinomaisesti datan l\u00e4hett\u00e4miseen yl\u00f6sp\u00e4in, mutta se ei korvaa reaaliaikaprotokollaa I\/O:lle ja taajuusmuuttajille.<\/li>\n<\/ol>\n<h2>Yhdysk\u00e4yt\u00e4v\u00e4t ja liit\u00e4nn\u00e4t SCN:lt\u00e4<\/h2>\n<p>Toimitamme protokollayhdysk\u00e4yt\u00e4vi\u00e4 muun muassa valmistajilta Moxa, HMS Networks (Ixxat), Weintek ja Duagon. Ne kattavat Modbusin, PROFINETin, EtherNet\/IP:n, PROFIBUSin, EtherCATin, CANopenin, J1939:n ja OPC UA:n sek\u00e4 junaprotokollat, kuten TRDP ja MVB. Valikoimaan kuuluu my\u00f6s CAN-liit\u00e4nt\u00f6j\u00e4 PC:ille ja sarjaliikennemuuntimia.<\/p>\n<h3>Esimerkkej\u00e4 valikoimastamme<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/mgate-5103-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/moxa-mgate-5103-main.webp\" alt=\"Moxa MGate 5103 Modbus\u2013PROFINET-yhdysk\u00e4yt\u00e4v\u00e4\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Moxa<\/span><span class=\"g-pn\">MGate 5103 Modbus\u2013PROFINET-yhdysk\u00e4yt\u00e4v\u00e4<\/span><span class=\"g-pw\">Kytkee Modbus RTU\/ASCII\/TCP- ja EtherNet\/IP-laitteet PROFINETiin IO-laitteena, enint\u00e4\u00e4n 512 tavua tulo- ja l\u00e4ht\u00f6dataa.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/cannet-nt-200-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/CANnet2520NT2520200.jpeg\" alt=\"HMS Networks Ixxat CAN@net NT 200 CAN\u2013Ethernet-yhdysk\u00e4yt\u00e4v\u00e4\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">HMS Networks<\/span><span class=\"g-pn\">Ixxat CAN@net NT 200 CAN\u2013Ethernet-yhdysk\u00e4yt\u00e4v\u00e4<\/span><span class=\"g-pw\">Yhdysk\u00e4yt\u00e4v\u00e4 ja silta CAN-v\u00e4yl\u00e4n ja Ethernetin v\u00e4lill\u00e4, kaksi CAN-kanavaa ja MQTT pilviyhteyksiin.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/fi\/tuote\/cmt-g01x-fi\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/weintek-cmt-g01x-main.webp\" alt=\"Weintek cMT-G01X IIoT-yhdysk\u00e4yt\u00e4v\u00e4, OPC UA ja MQTT\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Weintek<\/span><span class=\"g-pn\">cMT-G01X IIoT-yhdysk\u00e4yt\u00e4v\u00e4, OPC UA ja MQTT<\/span><span class=\"g-pw\">IIoT-yhdysk\u00e4yt\u00e4v\u00e4, jossa OPC UA -palvelin ja MQTT, yhdist\u00e4\u00e4 logiikat ja koneet ylemm\u00e4n tason j\u00e4rjestelmiin.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/industrial-connectivity-fi\/protocol-gateways-fi\/\">Protokollayhdysk\u00e4yt\u00e4v\u00e4t<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/bridges-gateways-fi\/\">Sillat ja yhdysk\u00e4yt\u00e4v\u00e4t<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/control-systems-fi\/gateways-fi\/\">Yhdysk\u00e4yt\u00e4v\u00e4t ohjausj\u00e4rjestelmiin<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/can-interfaces-fi\/\">CAN-liit\u00e4nn\u00e4t<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/industrial-connectivity-fi\/serial-converters\/\">Sarjaliikennemuuntimet<\/a><a href=\"https:\/\/scn.eu\/fi\/tuote-osasto\/tuotteita\/network-products-fi\/ethernet-fi\/\">Ethernet-kytkimet<\/a><\/div>\n<div class=\"g-cta\">\n<p>Pit\u00e4\u00e4k\u00f6 kahden j\u00e4rjestelm\u00e4n keskustella kesken\u00e4\u00e4n? Kerro insin\u00f6\u00f6reillemme laitteista ja protokollista \u2013 saat vastauksen 24 tunnin kuluessa.<\/p>\n<p><a href=\"https:\/\/scn.eu\/fi\/yhteystiedot\/\">Kysy insin\u00f6\u00f6rilt\u00e4<\/a><\/div>\n<h2>Usein kysytty\u00e4<\/h2>\n<details>\n<summary>Mit\u00e4 eroa on PROFIBUSilla ja PROFINETilla?<\/summary>\n<p>PROFIBUS on RS-485-pohjainen sarjamuotoinen kentt\u00e4v\u00e4yl\u00e4, jonka nopeus on enint\u00e4\u00e4n 12 Mbit\/s. PROFINET perustuu Ethernetiin, tarjoaa enemm\u00e4n kaistaa ja paremman diagnostiikan, ja uudet laitokset rakennetaan nyky\u00e4\u00e4n sill\u00e4. Molempia hallinnoi sama alan j\u00e4rjest\u00f6, PI.<\/p>\n<\/details>\n<details>\n<summary>Ovatko Modbus TCP ja Modbus RTU sama asia?<\/summary>\n<p>Niill\u00e4 on sama tietomalli ja samat funktiokoodit, mutta siirtotapa on eri. RTU toimii sarjamuotoisesti RS-485- tai RS-232-liit\u00e4nn\u00e4n kautta, TCP Ethernetin kautta. Yksinkertainen Modbus-yhdysk\u00e4yt\u00e4v\u00e4 k\u00e4\u00e4nt\u00e4\u00e4 niiden v\u00e4lill\u00e4.<\/p>\n<\/details>\n<details>\n<summary>Voivatko PROFINET ja EtherNet\/IP jakaa saman verkon?<\/summary>\n<p>Kyll\u00e4, ne voivat jakaa kaapelit ja kytkimet. Laitteet eiv\u00e4t kuitenkaan vaihda dataa suoraan kesken\u00e4\u00e4n. Siihen tarvitaan yhdysk\u00e4yt\u00e4v\u00e4 tai ohjain, joka puhuu molempia protokollia.<\/p>\n<\/details>\n<details>\n<summary>Miten EtherCAT eroaa PROFINETista?<\/summary>\n<p>EtherCAT lukee ja kirjoittaa dataa kehyksen kulkiessa jokaisen orjalaitteen l\u00e4pi, mik\u00e4 antaa liikkeenohjaukselle hyvin lyhyet kiertoajat. PROFINETia k\u00e4ytet\u00e4\u00e4n laajasti I\/O:lle ja taajuusmuuttajille, ja IRT-versio on tarkoitettu vaativaan liikkeenohjaukseen.<\/p>\n<\/details>\n<details>\n<summary>Onko OPC UA kentt\u00e4v\u00e4yl\u00e4protokolla?<\/summary>\n<p>Ei. OPC UA:ta k\u00e4ytet\u00e4\u00e4n p\u00e4\u00e4asiassa tiedonvaihtoon koneiden ja ylemm\u00e4n tason j\u00e4rjestelmien, kuten SCADAn, MES:n ja pilven, v\u00e4lill\u00e4. Kentt\u00e4tason versio OPC UA FX on olemassa, mutta se ei ole viel\u00e4 laajalti k\u00e4yt\u00f6ss\u00e4.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Logiikka puhuu PROFINETia, energiamittari Modbusia ja servok\u00e4ytt\u00f6 EtherCATia. T\u00e4ss\u00e4 oppaassa kerrotaan, mik\u00e4 erottaa yleisimm\u00e4t teollisuusprotokollat toisistaan, miss\u00e4 niit\u00e4 k\u00e4ytet\u00e4\u00e4n ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n, jotta ne saadaan keskustelemaan kesken\u00e4\u00e4n.<\/p>\n","protected":false},"author":11,"featured_media":8234382,"template":"","meta":{"_yoast_wpseo_focuskw":"teollisuuden ethernet-protokollat","_yoast_wpseo_metadesc":"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[879,877,889,12213,881,863],"_scn_guide_sectors":[1011,1080],"_scn_guide_type":"tech","_scn_guide_order":16,"footnotes":""},"class_list":["post-8234598","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus | SCN<\/title>\n<meta name=\"description\" content=\"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/\" \/>\n<meta property=\"og:locale\" content=\"fi_FI\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus | SCN\" \/>\n<meta property=\"og:description\" content=\"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:30:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f1-fi.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Arvioitu lukuaika\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minuuttia\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/\",\"name\":\"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\\\/IP, Modbus | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-protokoll-f1-fi.webp\",\"datePublished\":\"2026-10-24T17:26:33+00:00\",\"dateModified\":\"2026-10-24T17:30:35+00:00\",\"description\":\"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\\\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/#breadcrumb\"},\"inLanguage\":\"fi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-protokoll-f1-fi.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-protokoll-f1-fi.webp\",\"width\":1520,\"height\":560,\"caption\":\"Automaatiopyramidi ja tyypilliset protokollat: OPC UA ja MQTT SCADAn ja pilven suuntaan, PROFINET, EtherNet\\\/IP, EtherCAT ja Modbus TCP ohjaustasolla, IO-Link, Modbus RTU, CANopen ja PROFIBUS kentt\u00e4tasolla\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/oppaat\\\/teollisuuden-ethernet-protokollat\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\\\/IP, Modbus\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/fi\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fi\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/fi\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fi\",\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/fi\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus | SCN","description":"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/","og_locale":"fi_FI","og_type":"article","og_title":"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus | SCN","og_description":"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.","og_url":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:30:35+00:00","og_image":[{"width":1520,"height":560,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f1-fi.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Arvioitu lukuaika":"6 minuuttia"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/","url":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/","name":"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/fi\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f1-fi.webp","datePublished":"2026-10-24T17:26:33+00:00","dateModified":"2026-10-24T17:30:35+00:00","description":"Teollisuuden Ethernet-protokollat selitettyn\u00e4: PROFINET, EtherNet\/IP, Modbus, EtherCAT, CANopen ja OPC UA \u2013 k\u00e4ytt\u00f6kohteet ja milloin tarvitset yhdysk\u00e4yt\u00e4v\u00e4n.","breadcrumb":{"@id":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/#breadcrumb"},"inLanguage":"fi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/"]}]},{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f1-fi.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-protokoll-f1-fi.webp","width":1520,"height":560,"caption":"Automaatiopyramidi ja tyypilliset protokollat: OPC UA ja MQTT SCADAn ja pilven suuntaan, PROFINET, EtherNet\/IP, EtherCAT ja Modbus TCP ohjaustasolla, IO-Link, Modbus RTU, CANopen ja PROFIBUS kentt\u00e4tasolla"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/fi\/oppaat\/teollisuuden-ethernet-protokollat\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/fi\/"},{"@type":"ListItem","position":2,"name":"Teollisuuden Ethernet-protokollat \u2013 PROFINET, EtherNet\/IP, Modbus"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/fi\/#website","url":"https:\/\/scn.eu\/fi\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/fi\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/fi\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fi"},{"@type":"Organization","@id":"https:\/\/scn.eu\/fi\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/fi\/","logo":{"@type":"ImageObject","inLanguage":"fi","@id":"https:\/\/scn.eu\/fi\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/fi\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8234598","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8234598\/revisions"}],"predecessor-version":[{"id":8235010,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/scn_guide\/8234598\/revisions\/8235010"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/media\/8234382"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/fi\/wp-json\/wp\/v2\/media?parent=8234598"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}