SO1060
Supplied with mounting hardware (SO-1021-7127) or without mounting hardware (SO-1021-7126)
Supplied with mounting hardware (SO-1021-7127) or without mounting hardware (SO-1021-7126). Temperature range -70° C to +125° C. Weight 57g max.

Supplied with mounting hardware (SO-1021-7127) or without mounting hardware (SO-1021-7126)
Supplied with mounting hardware (SO-1021-7127) or without mounting hardware (SO-1021-7126). Temperature range -70° C to +125° C. Weight 57g max.

Supplied with mounting hardware and No. 12 contacts and crimp for power terminals; No. 16
Supplied with mounting hardware and No. 12 contacts and crimp for power terminals; No. 16 contacts and crimp for X coil; No. 22 contacts and crimp for Y coil. Temperature range -70° C to +125° C. Weight 27g max.

Supplied with mounting hardware and (6) No. 20 contacts, No. 20 crimp for power terminals;
Supplied with mounting hardware and (6) No. 20 contacts, No. 20 crimp for power terminals; (4) No. 22 contacts, No. 22 crimp for coil terminals. Temperature range -70° C to +125° C. Weight 15g max.

Supplied with mounting hardware and NO. 20 contacts and crimp for coil code J (SO-1064-104
Supplied with mounting hardware and NO. 20 contacts and crimp for coil code J (SO-1064-10444). Temperature range -70° C to +125° C. Weight 15g max.

Supplied with mounting hardware and No. 16 contacts and crimp for power terminals; No. 20
Supplied with mounting hardware and No. 16 contacts and crimp for power terminals; No. 20 contacts and crimp for coil terminals (SO-1065-10392) and (SO-1065-10393). Temperature range -70° C to +125° C. Weight 25g max.

Supplied with mounting hardware and No. 20 contacts and crimp for coil codes E, F, J, K (S
Supplied with mounting hardware and No. 20 contacts and crimp for coil codes E, F, J, K (SO-1066-10385) and (SO-1066-10386). Temperature range -70° C to +125° C. Weight 25g max.

SOB range Power and control connections by FASTON terminals. New 2 phases relays in okpacÂ
SOB range Power and control connections by FASTON terminals. New 2 phases relays in okpac® IP20 housing. Removable connector for control allowing many wiring possibilities eg. FASTONS, springs, screw and so on (please consult us).

SOB564330 Switching current: 2x40A Limited to 25A permanent due to the quick-connect termi
SOB564330 Switching current: 2x40A Limited to 25A permanent due to the quick-connect terminals. Switching voltage: 24-600VAC Peak voltage: 1200V Control voltage: 10-30VDC

SOB6: Double input with connector CE100F ITWPANCON type or similar.
SOB6: Double input with connector CE100F ITWPANCON type or similar.

SOB763670 Switching current: 2x35A Switching voltage: 24-510VAC Peak voltage: (V): 1200V C
SOB763670 Switching current: 2x35A Switching voltage: 24-510VAC Peak voltage: (V): 1200V Control voltage: 8-30VDC

SOB765670 Switching current: 2x50A Switching voltage: 24-510VAC Peak voltage (V): 1200V Co
SOB765670 Switching current: 2x50A Switching voltage: 24-510VAC Peak voltage (V): 1200V Control voltage: 8-30VDC

SOB767670 Switching current: 2x75A Switching voltage: 24-510VAC Peak voltage (V): 1200V Co
SOB767670 Switching current: 2x75A Switching voltage: 24-510VAC Peak voltage (V): 1200V Control voltage: 8-30VDC

SOB8: zero-cross- designed for most types of loads.
SOB8: zero-cross- designed for most types of loads.

SOB9: zero-cross- resistive loads AC-51
SOB9: zero-cross- resistive loads AC-51

SOB963660 Switching current: 2x35A Switching voltage: 24-600VAC Peak voltage (V): 1200V Co
SOB963660 Switching current: 2x35A Switching voltage: 24-600VAC Peak voltage (V): 1200V Control voltage: 10-30VDC

SOB965660 Switching current: 2x50A Switching voltage: 24-600VAC Peak voltage (V): 1200V Co
SOB965660 Switching current: 2x50A Switching voltage: 24-600VAC Peak voltage (V): 1200V Control voltage: 10-30VDC

SOB967660 Switching current: 2x75A Switching voltage: 24-600VAC Peak voltage (V): 1200V Co
SOB967660 Switching current: 2x75A Switching voltage: 24-600VAC Peak voltage (V): 1200V Control voltage: 10-30VDC

Dual Zero Cross Solid State Relay especially designed for AC-51 resistive loads. Back to b
Dual Zero Cross Solid State Relay especially designed for AC-51 resistive loads. Back to back thyristors on output with TMS2 (*) technology with a long lifetime expectancy: 24 to 600VAC 2x75A. Current limited by the connectors at 24A(*). High I²t model >6000A²s for possible MCB (Miniature Circuit Breaker) protection. 2 inputs with green LED visualization…

Dual Zero Cross Solid State Relay especially designed for AC-51 resistive loads. Back to b
Dual Zero Cross Solid State Relay especially designed for AC-51 resistive loads. Back to back thyristors on output with TMS2 (*) technology with a long lifetime expectancy: 24 to 600VAC 2x75A. Current limited by the connectors at 24A. High I²t model >6000A²s for MCB (Miniature Circuit Breaker) protection. 2 inputs with green LED visualization for…

In general slip rings are used to transmit power, signals or data from a stationary to a r
In general slip rings are used to transmit power, signals or data from a stationary to a rotating platform. 240 VAC/DC. Gold to gold contacts, 0…300 rpm and in strong engineering plastic.

In general slip rings are used to transmit power, signals or data from a stationary to a r
In general slip rings are used to transmit power, signals or data from a stationary to a rotating platform. 240 VAC/DC. Gold to gold contacts, 0…300 rpm and in strong engineering plastic.

In general slip rings are used to transmit power, signals or data from a stationary to a r
In general slip rings are used to transmit power, signals or data from a stationary to a rotating platform. 240 VAC/DC. Gold to gold contacts, 0…300 rpm and in strong engineering plastic.

In general slip rings are used to transmit power, signals or data from a stationary to a r
In general slip rings are used to transmit power, signals or data from a stationary to a rotating platform. 240 VAC/DC. Gold to gold contacts. 0…300 rpm and in strong engineering plastic.

In general slip rings are used to transmit power, signals or data from a stationary to a r
In general slip rings are used to transmit power, signals or data from a stationary to a rotating platform. 240 VAC/DC. Gold to gold contacts, 0…300 rpm and in strong engineering plastic.

The SPDU is an equipment that distributes the 28 Vdc power to the aircraft loads and provi
The SPDU is an equipment that distributes the 28 Vdc power to the aircraft loads and provides protection for their wiring. The SPDU can receive its input power from multiple sources and controls the loads based on the commands received through the data bus. The SSPCs can be commanded ON, OFF or reset through the…
Kui Teil on küsimusi meie toodete kohta, aitab tehisintellektist assistent Teil leida otsitavat.