{"id":8234676,"date":"2026-10-24T17:30:32","date_gmt":"2026-10-24T17:30:32","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234676"},"modified":"2026-10-24T17:32:45","modified_gmt":"2026-10-24T17:32:45","slug":"rele-contactor-o-ssr","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/","title":{"rendered":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir<\/h1>\n<p class=\"g-lead\">Un rel\u00e9, un rel\u00e9 de estado s\u00f3lido (SSR) y un contactor conectan y desconectan una carga con una peque\u00f1a se\u00f1al de mando. La elecci\u00f3n correcta depende de la corriente, la tensi\u00f3n, la frecuencia de conmutaci\u00f3n y de si la carga funciona en corriente alterna o continua.<\/p>\n<div class=\"g-short\"><b class=\"t\">Respuesta r\u00e1pida<\/b><\/p>\n<ul>\n<li><b>Rel\u00e9<\/b> \u2013 contactos mec\u00e1nicos para se\u00f1ales de mando y cargas peque\u00f1as, normalmente hasta 10\u201316 A. Econ\u00f3mico y con una separaci\u00f3n f\u00edsica real cuando est\u00e1 abierto.<\/li>\n<li><b>Rel\u00e9 de estado s\u00f3lido (SSR)<\/b> \u2013 sin piezas m\u00f3viles, silencioso y sin desgaste. Se calienta y a menudo necesita disipador.<\/li>\n<li><b>Contactor<\/b> \u2013 un rel\u00e9 de alta potencia para motores, calefacci\u00f3n y alimentaciones, a menudo trif\u00e1sico y de hasta cientos de amperios.<\/li>\n<li><b>La CC es m\u00e1s dif\u00edcil que la CA<\/b> \u2013 la corriente continua no pasa por cero para apagar el arco. Elige aparatos especificados para CC.<\/li>\n<li><b>Regla pr\u00e1ctica<\/b> \u2013 conmutaci\u00f3n frecuente: SSR. Conmutaci\u00f3n ocasional con corriente alta: contactor.<\/li>\n<\/ul>\n<\/div>\n<h2>\u00bfQu\u00e9 diferencia hay entre un rel\u00e9, un SSR y un contactor?<\/h2>\n<p>Un <b>rel\u00e9<\/b> tiene una bobina que atrae un contacto m\u00f3vil. El lado de mando y el lado de carga est\u00e1n aislados el\u00e9ctricamente. En carril DIN, los rel\u00e9s de interfaz permiten que una salida de PLC accione una v\u00e1lvula o una l\u00e1mpara.<\/p>\n<p>Un <b>rel\u00e9 de estado s\u00f3lido (SSR)<\/b> no tiene piezas m\u00f3viles. La se\u00f1al de mando enciende un LED en un optoacoplador, y la luz dispara un tiristor, un triac o un MOSFET que conduce la corriente de carga. La conmutaci\u00f3n es silenciosa y sin desgaste. El precio es el calor y una peque\u00f1a corriente de fuga incluso cuando est\u00e1 desconectado.<\/p>\n<p>Un <b>contactor<\/b> es, en esencia, un rel\u00e9 construido para alta potencia. Suele tener tres contactos principales para trif\u00e1sica, c\u00e1maras apagachispas y espacio para contactos auxiliares. Los contactores de CA se ensayan seg\u00fan la IEC 60947-4-1 con categor\u00edas de empleo, como AC-1 para cargas resistivas y AC-3 para arranque y parada de motores de inducci\u00f3n.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f1-es.webp\" alt=\"Esquema de principio: un rel\u00e9 tiene una bobina que atrae un contacto m\u00f3vil, un rel\u00e9 de estado s\u00f3lido acciona un tiristor a trav\u00e9s de un optoacoplador y un contactor tiene una bobina que atrae tres contactos principales a la vez\" width=\"1520\" height=\"500\" loading=\"lazy\" decoding=\"async\"><figcaption>Un rel\u00e9 y un contactor conmutan con contactos mec\u00e1nicos; un SSR, con un semiconductor.<\/figcaption><\/figure>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Caracter\u00edstica<\/th>\n<th>Rel\u00e9<\/th>\n<th>Rel\u00e9 de estado s\u00f3lido (SSR)<\/th>\n<th>Contactor<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">Corriente t\u00edpica<\/td>\n<td>Hasta 10\u201316 A<\/td>\n<td>De unos pocos A a unos 100 A por fase<\/td>\n<td>Desde unos 10 A hasta m\u00e1s de 1000 A<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Desgaste<\/td>\n<td>Los contactos se desgastan<\/td>\n<td>Sin desgaste mec\u00e1nico<\/td>\n<td>Los contactos se desgastan, pero son m\u00e1s robustos<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Conmutaci\u00f3n frecuente<\/td>\n<td>Poco adecuado<\/td>\n<td>Muy adecuado<\/td>\n<td>Poco adecuado<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Calor<\/td>\n<td>Bajo<\/td>\n<td>Unos 1\u20131,5 W por amperio<\/td>\n<td>Bajo<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Fallo t\u00edpico<\/td>\n<td>Contactos soldados<\/td>\n<td>El semiconductor falla en estado conductor<\/td>\n<td>Contactos soldados<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Calor, disipadores y paso por cero: lo que debes saber de los SSR<\/h2>\n<p>Un SSR con tiristores tiene una ca\u00edda de tensi\u00f3n de aproximadamente 1\u20131,5 V. Como regla pr\u00e1ctica, eso da 1\u20131,5 W de calor por amperio, de modo que un SSR que conduce 25 A disipa 25\u201340 W. La capacidad de un disipador se indica como resistencia t\u00e9rmica en K\/W: cuanto m\u00e1s baja, mejor. En un ejemplo de c\u00e1lculo de Celduc, uno de sus SSR con 40 A y 30 \u00b0C de temperatura ambiente necesita un disipador de 1,2 K\/W.<\/p>\n<p>Un SSR con <b>conmutaci\u00f3n en el paso por cero<\/b> solo conecta cuando la tensi\u00f3n alterna pasa por cero. As\u00ed se reducen las perturbaciones el\u00e9ctricas, y es adecuado para cargas resistivas como las resistencias calefactoras. Un SSR de <b>conmutaci\u00f3n instant\u00e1nea<\/b> conecta de inmediato y es adecuado para cargas inductivas como los transformadores, en los que conectar en el paso por cero puede provocar corrientes de arranque elevadas.<\/p>\n<div class=\"g-short\">\n<p style=\"margin:0\">Ejemplo: un regulador de temperatura activa un SSR cada segundo para mantener caliente una mordaza de sellado. Son m\u00e1s de 80 000 maniobras al d\u00eda, demasiadas para un rel\u00e9 mec\u00e1nico.<\/p>\n<\/div>\n<h2>CA o CC: por qu\u00e9 la corriente continua es m\u00e1s dif\u00edcil de cortar<\/h2>\n<p>Cuando los contactos se abren con carga, se forma un arco. Con corriente alterna, la corriente pasa por cero 100 veces por segundo a 50 Hz, y el arco se apaga en el siguiente paso por cero. La corriente continua no pasa por cero. El arco puede seguir ardiendo y destruir los contactos. Por eso un rel\u00e9 de 250 V CA a menudo solo admite 30 V CC con la misma corriente.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f2-es.webp\" alt=\"Diagrama: con corriente alterna el arco se apaga cuando la corriente pasa por cero; con corriente continua el arco sigue ardiendo hasta que se extingue activamente\" width=\"1520\" height=\"540\" loading=\"lazy\" decoding=\"async\"><figcaption>Con CA el arco se apaga solo en el paso por cero. Con CC hay que extinguirlo activamente.<\/figcaption><\/figure>\n<p>Por eso, los sistemas de bater\u00edas, los veh\u00edculos el\u00e9ctricos y las instalaciones solares usan <b>contactores de CC de alta tensi\u00f3n<\/b> para 400\u20131500 V. Los contactos van en una c\u00e1mara cer\u00e1mica herm\u00e9tica llena de gas, y unos imanes soplan el arco. Algunos modelos solo cortan la corriente plena en un sentido. Una bater\u00eda que se carga y se descarga necesita un contactor bidireccional. Los contactores de CC de estado s\u00f3lido cortan sin ning\u00fan arco.<\/p>\n<h2>Rel\u00e9s temporizadores, de vigilancia y de seguridad<\/h2>\n<ul>\n<li><b>Rel\u00e9 temporizador<\/b> \u2013 retarda la conexi\u00f3n o la desconexi\u00f3n, genera intermitencia o controla el arranque estrella-tri\u00e1ngulo de motores. Ejemplo: tiempo de post-ventilaci\u00f3n de un ventilador.<\/li>\n<li><b>Rel\u00e9 de vigilancia<\/b> \u2013 supervisa tensi\u00f3n, corriente, frecuencia, secuencia de fases o cos \u03c6 y dispara cuando un valor sale de su l\u00edmite. Ejemplo: un vigilante de frecuencia en un grupo electr\u00f3geno de reserva.<\/li>\n<li><b>Rel\u00e9 de seguridad<\/b> \u2013 supervisa paradas de emergencia, puertas de protecci\u00f3n y cortinas fotoel\u00e9ctricas. Tiene contactos de guiado forzado y dos canales, y se elige seg\u00fan el nivel de prestaciones (PL seg\u00fan EN ISO 13849-1) que exige la evaluaci\u00f3n de riesgos.<\/li>\n<\/ul>\n<h2>\u00bfCu\u00e1l elegir? Ejemplos de aplicaci\u00f3n<\/h2>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Si necesitas\u2026<\/th>\n<th>Elige<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Reforzar una salida de PLC para accionar una v\u00e1lvula o una l\u00e1mpara<\/td>\n<td>Rel\u00e9 de interfaz o rel\u00e9 de E\/S en carril DIN<\/td>\n<\/tr>\n<tr>\n<td>Controlar una calefacci\u00f3n con muchas maniobras por minuto<\/td>\n<td>SSR con paso por cero y disipador<\/td>\n<\/tr>\n<tr>\n<td>Arrancar y parar un motor trif\u00e1sico<\/td>\n<td>Contactor para AC-3 m\u00e1s protecci\u00f3n del motor<\/td>\n<\/tr>\n<tr>\n<td>Conectar y desconectar una bater\u00eda de 400\u20131500 V CC<\/td>\n<td>Contactor de CC de alta tensi\u00f3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<ul>\n<li><b>F\u00e1bricas<\/b> \u2013 rel\u00e9s de interfaz para electrov\u00e1lvulas, SSR para mordazas de sellado en m\u00e1quinas de envasado, contactores para cintas transportadoras.<\/li>\n<li><b>Veh\u00edculos y maquinaria m\u00f3vil<\/b> \u2013 contactores principales en carretillas el\u00e9ctricas, autobuses el\u00e9ctricos y maquinaria minera.<\/li>\n<li><b>Energ\u00eda<\/b> \u2013 almacenamiento en bater\u00edas y plantas solares a 1000\u20131500 V CC, vigilantes de frecuencia en generadores.<\/li>\n<li><b>Infraestructuras<\/b> \u2013 estaciones de bombeo con rel\u00e9s alternadores de bombas y rel\u00e9s temporizadores en ventilaci\u00f3n.<\/li>\n<li><b>Aeron\u00e1utica y defensa<\/b> \u2013 rel\u00e9s herm\u00e9ticos para \u221270 a +125 \u00b0C.<\/li>\n<li><b>Laboratorio y medicina<\/b> \u2013 SSR silenciosos para calefacci\u00f3n en incubadoras y analizadores.<\/li>\n<\/ul>\n<h2>Cinco errores habituales<\/h2>\n<ol class=\"g-pit\">\n<li><b>SSR sin disipador suficiente.<\/b> La corriente nominal solo es v\u00e1lida con la refrigeraci\u00f3n adecuada. Calcula con la temperatura dentro del armario.<\/li>\n<li><b>Rel\u00e9 para CA usado en CC.<\/b> Un valor de 10 A a 250 V CA no dice nada sobre CC. Comprueba los datos de CC en la hoja de datos.<\/li>\n<li><b>Categor\u00eda de empleo incorrecta.<\/b> Un contactor admite m\u00e1s corriente con cargas resistivas (AC-1) que con motores (AC-3). Dimensi\u00f3nalo para la carga.<\/li>\n<li><b>Olvidar la corriente de fuga.<\/b> Un SSR desconectado deja pasar unos pocos miliamperios, suficiente para que una l\u00e1mpara LED brille o una entrada de PLC lea un uno.<\/li>\n<li><b>Sin circuito de protecci\u00f3n.<\/b> Las cargas inductivas provocan picos de tensi\u00f3n al desconectarse, y las l\u00e1mparas y los condensadores, corrientes de arranque elevadas. Usa un diodo de libre circulaci\u00f3n, una red RC o un varistor.<\/li>\n<\/ol>\n<h2>Rel\u00e9s y contactores de SCN<\/h2>\n<p>Tenemos rel\u00e9s de interfaz de Mibbo y Tele Haase, rel\u00e9s de estado s\u00f3lido de Celduc, Mibbo y Nominal Controls, disipadores y accesorios para SSR de Celduc y contactores de CC de alta tensi\u00f3n de Gigavac y Rincon Power. Los rel\u00e9s temporizadores y de vigilancia son de Tele Haase, y los rel\u00e9s herm\u00e9ticos para aeron\u00e1utica, de Leach.<\/p>\n<h3>Ejemplos de nuestra gama<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/es\/producto\/sobr965560-th-es\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/SOBR965560-TH.jpeg\" alt=\"Celduc SOBR965560-TH Rel\u00e9 de estado s\u00f3lido doble 2\u00d724 A\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Celduc<\/span><span class=\"g-pn\">SOBR965560-TH Rel\u00e9 de estado s\u00f3lido doble 2\u00d724 A<\/span><span class=\"g-pw\">Novedad: rel\u00e9 de estado s\u00f3lido bif\u00e1sico con paso por cero y bornes push-in, 2 \u00d7 24 A a 24\u2013600 V CA, para cargas de calefacci\u00f3n.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/es\/producto\/gx16-es\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/gx16.jpeg\" alt=\"Gigavac Contactor GX16 para montaje en chasis\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Gigavac<\/span><span class=\"g-pn\">Contactor GX16 para montaje en chasis<\/span><span class=\"g-pw\">Contactor herm\u00e9tico para montaje en chasis, IP67 e IP69K, para \u221255 a 85 \u00b0C.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/es\/producto\/e1k-e3k-coupling-relays-es\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/tele-haase-coup-main.webp\" alt=\"Tele Haase E1K \/ E3K rel\u00e9s de interfaz\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Tele Haase<\/span><span class=\"g-pn\">E1K \/ E3K rel\u00e9s de interfaz<\/span><span class=\"g-pw\">Rel\u00e9s de interfaz para carril DIN, 8 A a 250 V, que a\u00edslan las salidas del PLC de la carga.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/es\/categoria-producto\/productos\/components-es\/relays-and-sockets-es\/\">Rel\u00e9s y z\u00f3calos<\/a><a href=\"https:\/\/scn.eu\/es\/categoria-producto\/productos\/components-es\/solid-state-relays-ssr-es\/\">Rel\u00e9s de estado s\u00f3lido (SSR)<\/a><a href=\"https:\/\/scn.eu\/es\/categoria-producto\/productos\/components-es\/power-contactors-es\/\">Contactores de potencia<\/a><a href=\"https:\/\/scn.eu\/es\/categoria-producto\/productos\/components-es\/timing-relays-es\/\">Rel\u00e9s temporizadores<\/a><a href=\"https:\/\/scn.eu\/es\/categoria-producto\/productos\/components-es\/monitoring-relays-es\/\">Rel\u00e9s de vigilancia<\/a><\/div>\n<div class=\"g-cta\">\n<p>\u00bfNo sabes si tu carga necesita un rel\u00e9, un SSR o un contactor? Pregunta a uno de nuestros ingenieros: te respondemos en menos de 24 horas.<\/p>\n<p><a href=\"https:\/\/scn.eu\/es\/contacto\/\">Pregunta a un ingeniero<\/a><\/div>\n<h2>Preguntas frecuentes<\/h2>\n<details>\n<summary>\u00bfQu\u00e9 diferencia hay entre un rel\u00e9 y un contactor?<\/summary>\n<p>Ambos usan una bobina para atraer contactos mec\u00e1nicos. Un contactor est\u00e1 construido para corrientes m\u00e1s altas y suele tener tres contactos principales para trif\u00e1sica. Los rel\u00e9s se usan sobre todo para se\u00f1ales de mando y cargas peque\u00f1as.<\/p>\n<\/details>\n<details>\n<summary>\u00bfPuede un rel\u00e9 de estado s\u00f3lido sustituir a un contactor?<\/summary>\n<p>A menudo s\u00ed, si la carga se conmuta con frecuencia y puedes evacuar el calor. Para motores y cuando quieres una separaci\u00f3n f\u00edsica en estado abierto, un contactor suele ser mejor.<\/p>\n<\/details>\n<details>\n<summary>\u00bfPor qu\u00e9 se calienta mi rel\u00e9 de estado s\u00f3lido?<\/summary>\n<p>Su ca\u00edda de tensi\u00f3n de aproximadamente 1\u20131,5 V da 1\u20131,5 W de calor por amperio. Sin disipador se sobrecalienta con unos pocos amperios.<\/p>\n<\/details>\n<details>\n<summary>\u00bfPuedo usar un rel\u00e9 de CA en CC?<\/summary>\n<p>Solo dentro de los valores de CC de la hoja de datos, que suelen ser mucho m\u00e1s bajos, porque un arco en CC es m\u00e1s dif\u00edcil de apagar.<\/p>\n<\/details>\n<details>\n<summary>\u00bfQu\u00e9 es un rel\u00e9 de interfaz?<\/summary>\n<p>Un rel\u00e9 entre el sistema de control y la carga. A\u00edsla la salida del PLC y permite que una salida d\u00e9bil conmute una corriente mayor o una tensi\u00f3n distinta.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Un rel\u00e9, un rel\u00e9 de estado s\u00f3lido (SSR) y un contactor conectan y desconectan una carga con una peque\u00f1a se\u00f1al de mando. La elecci\u00f3n correcta depende de la corriente, la tensi\u00f3n, la frecuencia de conmutaci\u00f3n y de si la carga funciona en corriente alterna o continua.<\/p>\n","protected":false},"author":11,"featured_media":8234401,"template":"","meta":{"_yoast_wpseo_focuskw":"rel\u00e9 de estado s\u00f3lido","_yoast_wpseo_metadesc":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[656,728,664,705,727],"_scn_guide_sectors":[1011,1037,1012],"_scn_guide_type":"tech","_scn_guide_order":36,"footnotes":""},"class_list":["post-8234676","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir | SCN<\/title>\n<meta name=\"description\" content=\"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir | SCN\" \/>\n<meta property=\"og:description\" content=\"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:32:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f1-es.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/\",\"name\":\"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-rela-f1-es.webp\",\"datePublished\":\"2026-10-24T17:30:32+00:00\",\"dateModified\":\"2026-10-24T17:32:45+00:00\",\"description\":\"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-rela-f1-es.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-rela-f1-es.webp\",\"width\":1520,\"height\":500,\"caption\":\"Esquema de principio: un rel\u00e9 tiene una bobina que atrae un contacto m\u00f3vil, un rel\u00e9 de estado s\u00f3lido acciona un tiristor a trav\u00e9s de un optoacoplador y un contactor tiene una bobina que atrae tres contactos principales a la vez\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/guias\\\/rele-contactor-o-ssr\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/es\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir | SCN","description":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/","og_locale":"es_ES","og_type":"article","og_title":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir | SCN","og_description":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.","og_url":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:32:45+00:00","og_image":[{"width":1520,"height":500,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f1-es.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"8 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/","url":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/","name":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f1-es.webp","datePublished":"2026-10-24T17:30:32+00:00","dateModified":"2026-10-24T17:32:45+00:00","description":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido (SSR): diferencias en corriente, vida \u00fatil, calor y corte en CA y CC, y c\u00f3mo elegir seg\u00fan tu carga.","breadcrumb":{"@id":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f1-es.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-rela-f1-es.webp","width":1520,"height":500,"caption":"Esquema de principio: un rel\u00e9 tiene una bobina que atrae un contacto m\u00f3vil, un rel\u00e9 de estado s\u00f3lido acciona un tiristor a trav\u00e9s de un optoacoplador y un contactor tiene una bobina que atrae tres contactos principales a la vez"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/es\/guias\/rele-contactor-o-ssr\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/es\/"},{"@type":"ListItem","position":2,"name":"Rel\u00e9, contactor o rel\u00e9 de estado s\u00f3lido: cu\u00e1l elegir"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/es\/#website","url":"https:\/\/scn.eu\/es\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/scn.eu\/es\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/scn.eu\/es\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/es\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/scn_guide\/8234676","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/scn_guide\/8234676\/revisions"}],"predecessor-version":[{"id":8235118,"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/scn_guide\/8234676\/revisions\/8235118"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/media\/8234401"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/es\/wp-json\/wp\/v2\/media?parent=8234676"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}