{"id":8234494,"date":"2026-10-24T17:31:45","date_gmt":"2026-10-24T17:31:45","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234494"},"modified":"2026-10-24T17:31:45","modified_gmt":"2026-10-24T17:31:45","slug":"variable-frequency-drives","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/","title":{"rendered":"Variable frequency drives \u2013 how to choose the right VFD"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Variable frequency drives \u2013 how to choose the right VFD<\/h1>\n<p class=\"g-lead\">A variable frequency drive controls the speed of an electric motor and often saves a lot of energy in pumps and fans. This guide covers control methods, sizing, braking, EMC and safety.<\/p>\n<div class=\"g-short\"><b class=\"t\">Short answer<\/b><\/p>\n<ul>\n<li><b>Function<\/b> \u2013 the drive turns the fixed 50 Hz of the mains into a variable frequency and voltage, giving fully adjustable speed.<\/li>\n<li><b>Size by current<\/b> \u2013 start with the motor rated current and the overload the load needs, not just the power.<\/li>\n<li><b>Normal or heavy duty<\/b> \u2013 pumps and fans usually manage with normal duty. Conveyors, cranes and presses need heavy duty.<\/li>\n<li><b>Braking<\/b> \u2013 large inertias and lowering loads need a braking resistor or regeneration to the grid.<\/li>\n<li><b>Installation<\/b> \u2013 shielded motor cable, the right EMC filter and STO matter as much as the choice of drive.<\/li>\n<\/ul>\n<\/div>\n<h2>What does a variable frequency drive do?<\/h2>\n<p>An induction motor on the mains runs at almost constant speed \u2013 a four-pole motor at 50 Hz at just under 1,500 rpm. A VFD rectifies the mains voltage into a DC voltage in the DC link. An inverter with IGBT transistors then creates a new three-phase voltage with any frequency and voltage. The motor speed is then fully adjustable, with soft starts and stops. The drive controls both induction motors and permanent magnet (PM) motors, which are more efficient but usually cannot run directly on the mains.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f1-en.webp\" alt=\"Block diagram: mains, rectifier, DC link, inverter and motor, with a brake chopper and braking resistor connected to the DC link.\" width=\"1520\" height=\"472\" loading=\"lazy\" decoding=\"async\"><figcaption>Rectifier, DC link and inverter. During braking, a brake chopper absorbs the energy.<\/figcaption><\/figure>\n<h3>Why does speed control save energy?<\/h3>\n<p>In centrifugal pumps and fans, the power demand rises roughly with the cube of the speed. At 80 per cent speed, the motor in theory needs only about half the power. With throttling, the motor runs at full speed and the energy is wasted in the valve or damper. Static head or back pressure reduces the saving, but it is often still large.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f2-en.webp\" alt=\"Bar chart: power demand at 100, 90, 80, 70, 60 and 50 per cent speed is 100, 73, 51, 34, 22 and 13 per cent.\" width=\"1520\" height=\"512\" loading=\"lazy\" decoding=\"async\"><figcaption>Theoretical power demand of a pump or fan without static head.<\/figcaption><\/figure>\n<h3>Where are VFDs used?<\/h3>\n<ul>\n<li><b>Buildings<\/b> \u2013 fans, circulation pumps and chillers in ventilation and heating.<\/li>\n<li><b>Water and wastewater<\/b> \u2013 pumping stations and blowers in treatment plants. Soft starts and stops reduce water hammer.<\/li>\n<li><b>Factories and machine building<\/b> \u2013 conveyors, mixers, extruders and compressors.<\/li>\n<li><b>Lifting<\/b> \u2013 overhead cranes, gantry cranes and lifts, where the drive handles the brake sequence.<\/li>\n<li><b>Energy and marine<\/b> \u2013 cooling water pumps in power plants and winches on ships.<\/li>\n<\/ul>\n<h2>V\/f control or vector control?<\/h2>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Control method<\/th>\n<th>How it works<\/th>\n<th>Suitable for<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">V\/f control<\/td>\n<td>Voltage follows frequency in a fixed ratio.<\/td>\n<td>Pumps, fans and several motors on one drive.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Sensorless vector control<\/td>\n<td>The drive calculates motor flux and torque from current and voltage.<\/td>\n<td>Most machines. Good torque at low speed.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Closed-loop vector control<\/td>\n<td>An encoder feeds back the actual speed.<\/td>\n<td>Full torque at standstill, hoists and winders.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>PM motors generally need vector control. During commissioning, auto-tuning measures the motor data. Do not skip it.<\/p>\n<h2>Sizing \u2013 current, overload and duty<\/h2>\n<p>Start with the motor rated current. Two 15 kW motors can differ in current depending on pole count and efficiency.<\/p>\n<p>Many drives have two ratings: <b>normal duty (ND)<\/b> for variable torque loads such as pumps and fans, and <b>heavy duty (HD)<\/b> for constant torque and heavy starts, as in conveyors and mixers. Typically, normal duty allows 110 % overload for 60 seconds and heavy duty 150 % for 60 seconds. Hoisting needs full torque at standstill, mechanical brake control and often an encoder.<\/p>\n<p>Ratings apply at a given temperature, altitude and switching frequency. A hot cabinet, altitudes above 1,000 metres or a higher switching frequency often mean derating.<\/p>\n<h2>Braking and regeneration<\/h2>\n<p>When a motor brakes or lowers a load, it acts as a generator. Energy flows back into the DC link and the voltage rises until the drive trips on overvoltage.<\/p>\n<ul>\n<li><b>Braking resistor<\/b> \u2013 a brake chopper switches in a resistor that turns the energy into heat. Simple and inexpensive. Smaller drives often have the brake chopper built in.<\/li>\n<li><b>Regenerative braking unit<\/b> \u2013 returns the energy to the grid. Pays off with frequent braking in cranes, lifts and centrifuges.<\/li>\n<li><b>Active front end or matrix converter<\/b> \u2013 the drive itself regenerates and draws a nearly sinusoidal current from the grid, with very low harmonics.<\/li>\n<\/ul>\n<h2>EMC, motor cable and bearing currents<\/h2>\n<p>Fast switching in the drive causes high-frequency interference, and the rectifier causes mains harmonics. The standard EN 61800-3 divides drive systems into categories:<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Category<\/th>\n<th>Environment<\/th>\n<th>Example<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">C1<\/td>\n<td>Residential and offices<\/td>\n<td>Small drives in buildings, often with an extra filter.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">C2<\/td>\n<td>As C1, installed by a professional<\/td>\n<td>Buildings. Many drives have a built-in C2 filter.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">C3<\/td>\n<td>Industrial<\/td>\n<td>Factories with their own transformer.<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">C4<\/td>\n<td>Industrial, at least 1,000 V or 400 A<\/td>\n<td>Large drive systems with an EMC plan.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<ul>\n<li><b>Shielded motor cable<\/b> \u2013 terminate the shield all the way round (360\u00b0) at both ends with EMC cable glands.<\/li>\n<li><b>Long cables<\/b> \u2013 reflections can give voltage peaks of up to twice the DC link voltage at the motor. Above the maker\u2019s limit, use a dV\/dt or sine filter.<\/li>\n<li><b>RCDs<\/b> \u2013 the EMC filter causes leakage current, and a fault can cause DC current to earth. Three-phase drives often need a type B RCD.<\/li>\n<\/ul>\n<p><b>Bearing currents<\/b> occur when the common mode voltage from the drive discharges through the motor bearings, etching flutes into the races. The bearing can then fail within months. The risk grows with motor size. Countermeasures are insulated bearings, a shaft grounding ring, common mode filters and correct shielding.<\/p>\n<h2>Communication, STO and mounting<\/h2>\n<p>Simple systems use digital inputs and a 0\u201310 V or 4\u201320 mA reference. Modern machines usually use a network: <b>PROFINET<\/b> in Siemens environments, <b>EtherNet\/IP<\/b> with Rockwell, <b>EtherCAT<\/b> in machines with motion control and <b>Modbus<\/b> or BACnet in pumping stations and buildings. The control system can then also read current, torque, energy use and alarms.<\/p>\n<p><b>STO (Safe Torque Off)<\/b> removes motor torque through two independent channels. The function is defined in IEC 61800-5-2 and corresponds to stop category 0 in IEC 60204-1. With a safety card you can also get SS1, a controlled stop followed by STO. STO does not replace an isolator \u2013 the motor cable is still live.<\/p>\n<p>Most drives are IP20 for cabinet mounting, where a few per cent of the power becomes heat to be removed. IP55 models are available for mounting out in the plant.<\/p>\n<h2>Common mistakes<\/h2>\n<ol class=\"g-pit\">\n<li><b>Choosing the drive by kW.<\/b> A motor with many poles or low efficiency draws more current than a four-pole motor of the same power.<\/li>\n<li><b>A contactor breaks the motor circuit during operation.<\/b> This can damage the drive output stage. Stop with STO or a stop command first.<\/li>\n<li><b>Forgetting the braking requirement.<\/b> A large fan or a downhill conveyor can trip on overvoltage at every stop.<\/li>\n<li><b>Running the motor at low speed and high torque for long periods.<\/b> A self-ventilated motor then overheats. Use a separate cooling fan or a larger motor.<\/li>\n<\/ol>\n<h2>Variable frequency drives from SCN<\/h2>\n<p>We offer drives from Yaskawa: general-purpose models from 0.1 kW, high-performance drives up to 630 kW and dedicated models for buildings, cranes and lifts, as well as regenerative braking units and the U1000 matrix converter. Tell us about the motor, load and environment, and we will help you choose size and options.<\/p>\n<h3>Examples from our range<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/en\/product\/hv600-hvac-inverter\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/yaskawa-hv600-main.webp\" alt=\"Yaskawa HV600 HVAC Inverter\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Yaskawa<\/span><span class=\"g-pn\">HV600 HVAC Inverter<\/span><span class=\"g-pw\">For fans, pumps and compressors in buildings, with built-in C2 EMC filter, BACnet and Modbus RTU.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/en\/product\/cr700-crane-inverter\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/yaskawa-cr700-main.webp\" alt=\"Yaskawa CR700 Crane Inverter\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Yaskawa<\/span><span class=\"g-pn\">CR700 Crane Inverter<\/span><span class=\"g-pw\">Crane drive from 0.55 to 315 kW with a dedicated brake sequence and load check.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/en\/product\/u1000\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/U1000.png\" alt=\"Yaskawa U1000\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Yaskawa<\/span><span class=\"g-pn\">U1000<\/span><span class=\"g-pw\">Matrix converter with ultra-low harmonics and full regeneration of braking energy.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/drives-and-motion\/frequency-inverters\/\">Frequency inverters<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/drives-and-motion\/frequency-inverters\/special-inverters\/\">Special inverters<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/drives-and-motion\/\">Drives and motion<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/drives-and-motion\/servo-motors\/\">Servo motors<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/sensors\/incremental-encoders\/\">Incremental encoders<\/a><\/div>\n<div class=\"g-cta\">\n<p>Unsure about size, braking or EMC filter? Ask one of our engineers \u2013 you get an answer within 24 hours.<\/p>\n<p><a href=\"https:\/\/scn.eu\/en\/contact\/\">Ask an engineer<\/a><\/div>\n<h2>Frequently asked questions<\/h2>\n<details>\n<summary>What is the difference between a VFD and a soft starter?<\/summary>\n<p>A soft starter only gives a smooth start, then the motor runs at full speed. A VFD controls the speed all the time and can therefore save energy.<\/p>\n<\/details>\n<details>\n<summary>Can I run a standard motor on a VFD?<\/summary>\n<p>Yes, most modern induction motors can. With long cables, a 690 V supply and large motors, check the motor insulation and protection against bearing currents.<\/p>\n<\/details>\n<details>\n<summary>What does STO mean on a VFD?<\/summary>\n<p>Safe Torque Off, a safety function that removes motor torque through two independent channels. It does not replace an isolator for electrical work.<\/p>\n<\/details>\n<details>\n<summary>Can a VFD run on single-phase power?<\/summary>\n<p>Yes, smaller drives take 230 V single-phase input and still supply three-phase to the motor, which is then usually connected in delta.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A variable frequency drive controls the speed of an electric motor and often saves a lot of energy in pumps and fans. This guide covers control methods, sizing, braking, EMC and safety.<\/p>\n","protected":false},"author":11,"featured_media":8234459,"template":"","meta":{"_yoast_wpseo_focuskw":"variable frequency drive","_yoast_wpseo_metadesc":"How to choose a variable frequency drive: V\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[907,906],"_scn_guide_sectors":[1011,1012],"_scn_guide_type":"tech","_scn_guide_order":40,"footnotes":""},"class_list":["post-8234494","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Variable frequency drives \u2013 how to choose the right VFD | SCN<\/title>\n<meta name=\"description\" content=\"How to choose a variable frequency drive: V\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Variable frequency drives \u2013 how to choose the right VFD | SCN\" \/>\n<meta property=\"og:description\" content=\"How to choose a variable frequency drive: V\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f1-en.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"472\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/\",\"name\":\"Variable frequency drives \u2013 how to choose the right VFD | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-frekvensomriktare-f1-en.webp\",\"datePublished\":\"2026-10-24T17:31:45+00:00\",\"description\":\"How to choose a variable frequency drive: V\\\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-frekvensomriktare-f1-en.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-frekvensomriktare-f1-en.webp\",\"width\":1520,\"height\":472,\"caption\":\"Block diagram: mains, rectifier, DC link, inverter and motor, with a brake chopper and braking resistor connected to the DC link.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/variable-frequency-drives\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Variable frequency drives \u2013 how to choose the right VFD\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/en\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Variable frequency drives \u2013 how to choose the right VFD | SCN","description":"How to choose a variable frequency drive: V\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/","og_locale":"en_US","og_type":"article","og_title":"Variable frequency drives \u2013 how to choose the right VFD | SCN","og_description":"How to choose a variable frequency drive: V\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.","og_url":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/","og_site_name":"SCN","og_image":[{"width":1520,"height":472,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f1-en.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/","url":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/","name":"Variable frequency drives \u2013 how to choose the right VFD | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f1-en.webp","datePublished":"2026-10-24T17:31:45+00:00","description":"How to choose a variable frequency drive: V\/f or vector control, sizing, braking resistors, EMC filters, motor cables and STO. A practical guide from SCN.","breadcrumb":{"@id":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f1-en.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-frekvensomriktare-f1-en.webp","width":1520,"height":472,"caption":"Block diagram: mains, rectifier, DC link, inverter and motor, with a brake chopper and braking resistor connected to the DC link."},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/en\/guides\/variable-frequency-drives\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/en\/"},{"@type":"ListItem","position":2,"name":"Variable frequency drives \u2013 how to choose the right VFD"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/en\/#website","url":"https:\/\/scn.eu\/en\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/scn.eu\/en\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scn.eu\/en\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide\/8234494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide\/8234494\/revisions"}],"predecessor-version":[{"id":8234501,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide\/8234494\/revisions\/8234501"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/media\/8234459"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/media?parent=8234494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}