{"id":8234153,"date":"2026-10-24T17:27:02","date_gmt":"2026-10-24T17:27:02","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234153"},"modified":"2026-10-24T17:29:29","modified_gmt":"2026-10-24T17:29:29","slug":"fiber-media-converter","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/","title":{"rendered":"Fiber media converter \u2013 how to choose the right one"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Fiber media converter \u2013 how to choose the right one<\/h1>\n<p class=\"g-lead\">A media converter connects copper cable to fiber, so Ethernet can reach beyond 100 metres and withstand electrical interference. This guide covers single-mode and multimode, SFP, reach and what sets an industrial converter apart from an office model.<\/p>\n<div class=\"g-short\"><b class=\"t\">Short answer<\/b><\/p>\n<ul>\n<li><b>Why fiber<\/b> \u2013 copper reaches 100 metres. Fiber reaches kilometres, is not affected by electrical interference and breaks the galvanic connection.<\/li>\n<li><b>Multimode<\/b> \u2013 for shorter runs within a site: up to about 2 km at 100 Mbit\/s, a few hundred metres at gigabit.<\/li>\n<li><b>Single-mode<\/b> \u2013 for long distances, from 10 km upwards depending on the optics.<\/li>\n<li><b>SFP slot<\/b> \u2013 you choose fiber type and reach with an exchangeable module.<\/li>\n<li>Both ends must match: fiber type, wavelength, speed and connector.<\/li>\n<\/ul>\n<\/div>\n<h2>What does a media converter do?<\/h2>\n<p>A media converter receives Ethernet on a copper port (RJ45 or M12) and sends the same traffic on as light in a fiber. At the other end sits a second converter, or a switch with a fiber port, which turns the light back into electrical signals. The protocol does not matter: PROFINET, EtherNet\/IP, Modbus TCP, video and ordinary IT traffic pass through unchanged.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f1-en.webp\" alt=\"A pair of media converters extends an Ethernet link: copper up to 100 metres, fiber between building A and B, then copper to a camera, I\/O or PLC\" width=\"1520\" height=\"490\" loading=\"lazy\" decoding=\"async\"><figcaption>Two media converters extend Ethernet beyond the 100-metre limit of copper.<\/figcaption><\/figure>\n<p>The need usually arises because twisted-pair copper Ethernet is limited to 100 metres \u2013 rarely enough between two buildings, along a long conveyor or out to a camera at the gate.<\/p>\n<h2>When do you need fiber instead of copper?<\/h2>\n<ul>\n<li><b>Long distances<\/b> \u2013 links over 100 metres, between buildings, in tunnels and across wind farms.<\/li>\n<li><b>Electrical interference (EMC)<\/b> \u2013 near drives, welders, induction furnaces and power cables. Light in the fiber is not affected by electromagnetic fields.<\/li>\n<li><b>Potential differences and lightning<\/b> \u2013 buildings at different earth potential can drive current through the cable screen. Fiber does not conduct and breaks the connection.<\/li>\n<\/ul>\n<h3>Examples from different industries<\/h3>\n<ul>\n<li><b>Factories and process plants<\/b> \u2013 links between control cabinets in different halls, or past drives and welding robots.<\/li>\n<li><b>Energy<\/b> \u2013 substations and switchgear, where converters to IEC 61850-3 withstand the electrical environment. Also solar and wind farms with long distances.<\/li>\n<li><b>Infrastructure<\/b> \u2013 traffic monitoring, tunnels and pumping stations. Converters with PoE power cameras and access points at the far end of the fiber.<\/li>\n<li><b>Railways<\/b> \u2013 along the track and in depots, where fiber handles long runs and interference from the overhead line.<\/li>\n<li><b>Vehicles and defence<\/b> \u2013 sealed IP67 converters with military connectors for ships, aircraft and ground vehicles.<\/li>\n<li><b>Hospitals and medical technology<\/b> \u2013 fiber between buildings and in areas with interference-sensitive medical equipment.<\/li>\n<\/ul>\n<h2>Single-mode or multimode?<\/h2>\n<p>Fiber comes in two main types. In multimode fiber the core is wide and the light travels along several paths, which limits the distance. In single-mode fiber the core is so narrow that the light takes only one path, giving very long reach.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f2-en.webp\" alt=\"Comparison of multimode and single-mode fiber: in multimode the light takes several paths in a wide core, in single-mode one path in a narrow core\" width=\"1520\" height=\"480\" loading=\"lazy\" decoding=\"async\"><figcaption>Multimode has a wide core and several light paths. Single-mode has a narrow core and reaches much further.<\/figcaption><\/figure>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>Multimode<\/th>\n<th>Single-mode<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">Core<\/td>\n<td>50 or 62.5 \u00b5m<\/td>\n<td>About 9 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Wavelength<\/td>\n<td>850 and 1300 nm<\/td>\n<td>1310 and 1550 nm<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">100 Mbit\/s<\/td>\n<td>Up to about 2 km<\/td>\n<td>Tens of kilometres<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Gigabit<\/td>\n<td>About 220\u2013550 m depending on fiber<\/td>\n<td>10 km and beyond depending on module<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Jacket colour<\/td>\n<td>Often orange or aqua<\/td>\n<td>Often yellow<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">Suited to<\/td>\n<td>Within buildings and sites<\/td>\n<td>Between buildings and over long distances<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Start from the fiber already installed on site. If it is multimode, check the category (OM1\u2013OM4), as it affects reach. If new fiber is to be laid, single-mode is often the most future-proof choice.<\/p>\n<h2>SFP, connectors and wavelengths<\/h2>\n<p>Many converters have an SFP slot instead of a fixed fiber port. An SFP (small form-factor pluggable) is a small exchangeable module that sets fiber type, wavelength and reach. You can then move from multimode to single-mode without replacing the converter. The most common connector on SFP modules is LC, while fixed fiber ports often use SC or ST.<\/p>\n<p>There are also single-fiber modules (WDM or BiDi) that transmit on one wavelength and receive on another, for example 1310 and 1550 nm. They are used in pairs with opposite wavelengths and save one fiber.<\/p>\n<h2>Managed or unmanaged \u2013 and industrial requirements<\/h2>\n<p>Most media converters are unmanaged and work straight away without configuration. A managed converter can be monitored remotely, for example via SNMP or IEEE 802.3ah OAM, and reports link status and faults. It pays off with many links or remote sites.<\/p>\n<p>A good middle ground is Link Fault Pass-Through (LFP). If the fiber link goes down, the converter also shuts the copper port, so the switch sees the fault and can raise an alarm or switch to a backup path.<\/p>\n<h3>What an industrial converter should handle<\/h3>\n<ul>\n<li><b>Temperature<\/b> \u2013 office models are built for room temperature. Industrial versions are available for \u221240 to 75 \u00b0C.<\/li>\n<li><b>Mounting and power<\/b> \u2013 DIN rail, metal housing and dual power inputs, often 12\u201348 V DC.<\/li>\n<li><b>Alarms<\/b> \u2013 a relay output that signals power loss or link failure.<\/li>\n<li><b>Approvals<\/b> \u2013 for example IEC 61850-3 for substations, EN 50155 for rail vehicles and Class I Division 2 or ATEX Zone 2 for hazardous areas.<\/li>\n<\/ul>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>If you need to \u2026<\/th>\n<th>\u2026 choose<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Extend a link within a site<\/td>\n<td>Multimode, or an SFP slot for flexibility<\/td>\n<\/tr>\n<tr>\n<td>Connect buildings or sites several kilometres apart<\/td>\n<td>Single-mode<\/td>\n<\/tr>\n<tr>\n<td>Power a camera or access point far away<\/td>\n<td>Converter with PoE<\/td>\n<\/tr>\n<tr>\n<td>Monitor many links from a central point<\/td>\n<td>Managed converter, preferably in a rack<\/td>\n<\/tr>\n<tr>\n<td>Install outdoors, in vehicles or on ships<\/td>\n<td>Sealed IP67 converter with a wide temperature range<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Five common mistakes<\/h2>\n<ol class=\"g-pit\">\n<li><b>The ends do not match.<\/b> Multimode at one end and single-mode at the other, different wavelengths, or 100 Mbit\/s against gigabit gives no link. Check both sides before ordering.<\/li>\n<li><b>The SFP module cannot handle the environment.<\/b> A converter rated for \u221240 \u00b0C does not help if the SFP module is only made for room temperature. Choose modules with an industrial temperature range.<\/li>\n<li><b>No LFP.<\/b> Without Link Fault Pass-Through the switch does not notice that the fiber has broken, and redundancy does not switch over.<\/li>\n<li><b>Dirty connectors.<\/b> Dust and grease on end faces commonly cause attenuation and intermittent faults. Clean and inspect connectors during installation.<\/li>\n<li><b>Bends too tight.<\/b> Fiber bent too sharply loses light. Follow the cable manufacturer\u2019s minimum bend radius in cable trays and cabinets.<\/li>\n<\/ol>\n<h2>Media converters from SCN<\/h2>\n<p>We supply media converters from Moxa, ORing and Enercon: from compact DIN-rail converters and slide-in rack modules to IP67-rated models for military platforms. Several are available with PoE, an SFP slot and a temperature range down to \u221240 \u00b0C.<\/p>\n<h3>Examples from our range<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/en\/product\/imc-101g\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/IMC-101G.jpg\" alt=\"Moxa IMC-101G Industrial Gigabit Ethernet-to-fiber\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Moxa<\/span><span class=\"g-pn\">IMC-101G Industrial Gigabit Ethernet-to-fiber<\/span><span class=\"g-pw\">Gigabit converter with SFP slot, LFP, relay alarm output and redundant power inputs. The -T models handle \u221240 to 75 \u00b0C.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/en\/product\/ipmc111pb\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/IPMC-111PB.jpg\" alt=\"ORing IPMC-111PB\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">ORing<\/span><span class=\"g-pn\">IPMC-111PB<\/span><span class=\"g-pw\">Fast Ethernet to fiber with SFP slot and IEEE 802.3at PoE up to 30 W, for \u221240 to 70 \u00b0C.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/en\/product\/enercon-miltech-1000\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/enercon-miltech-1000-series-main.webp\" alt=\"Enercon MILTECH 1000 military Gigabit media converter\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Enercon<\/span><span class=\"g-pn\">MILTECH 1000 military Gigabit media converter<\/span><span class=\"g-pw\">Rugged IP67 gigabit converter with fiber links up to 120 km and cold start from \u221245 \u00b0C.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/network-products\/ethernet-media-converters\/\">Ethernet media converters<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/network-products\/ethernet\/\">Ethernet switches<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/network-products\/ethernet\/managed-switches\/\">Managed switches<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/network-products\/ethernet\/unmanaged-switches\/\">Unmanaged switches<\/a><a href=\"https:\/\/scn.eu\/en\/product-category\/products\/network-products\/\">Network products<\/a><\/div>\n<div class=\"g-cta\">\n<p>Unsure about fiber type, reach or SFP? Tell our engineers about the route and the environment \u2013 you get an answer within 24 hours.<\/p>\n<p><a href=\"https:\/\/scn.eu\/en\/contact\/\">Ask an engineer<\/a><\/div>\n<h2>Frequently asked questions<\/h2>\n<details>\n<summary>How far can a media converter reach?<\/summary>\n<p>It depends on the fiber and the optics. Multimode reaches from a few hundred metres at gigabit up to about 2 km at 100 Mbit\/s. Single-mode normally reaches 10 km or more, and some models over 100 km.<\/p>\n<\/details>\n<details>\n<summary>Can you mix single-mode and multimode?<\/summary>\n<p>No, both ends of a link must use the same fiber type and wavelength. Joining two different fiber networks takes equipment with a port of each kind, such as a switch with two SFP slots.<\/p>\n<\/details>\n<details>\n<summary>Do you always need two media converters?<\/summary>\n<p>No. The other end can be a switch or another device with a fiber port or SFP slot. What matters is that fiber type, wavelength and speed match.<\/p>\n<\/details>\n<details>\n<summary>What is the difference between a media converter and a switch with a fiber port?<\/summary>\n<p>A media converter usually connects one device, with one copper and one fiber port. A switch with a fiber port serves several devices and can add VLANs and redundancy.<\/p>\n<\/details>\n<details>\n<summary>Does a media converter delay real-time traffic?<\/summary>\n<p>The delay is small, from a few microseconds up to around a tenth of a millisecond depending on speed and frame size. It normally does not affect PROFINET or EtherNet\/IP.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A media converter connects copper cable to fiber, so Ethernet can reach beyond 100 metres and withstand electrical interference. This guide covers single-mode and multimode, SFP, reach and what sets an industrial converter apart from an office model.<\/p>\n","protected":false},"author":11,"featured_media":8234056,"template":"","meta":{"_yoast_wpseo_focuskw":"fiber media converter","_yoast_wpseo_metadesc":"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[872,863],"_scn_guide_sectors":[1011,1080,1012],"_scn_guide_type":"tech","_scn_guide_order":20,"footnotes":""},"class_list":["post-8234153","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fiber media converter \u2013 how to choose the right one | SCN<\/title>\n<meta name=\"description\" content=\"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fiber media converter \u2013 how to choose the right one | SCN\" \/>\n<meta property=\"og:description\" content=\"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:29:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f1-en.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"490\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/\",\"name\":\"Fiber media converter \u2013 how to choose the right one | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-mediaomvandlare-f1-en.webp\",\"datePublished\":\"2026-10-24T17:27:02+00:00\",\"dateModified\":\"2026-10-24T17:29:29+00:00\",\"description\":\"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-mediaomvandlare-f1-en.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-mediaomvandlare-f1-en.webp\",\"width\":1520,\"height\":490,\"caption\":\"A pair of media converters extends an Ethernet link: copper up to 100 metres, fiber between building A and B, then copper to a camera, I\\\/O or PLC\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/guides\\\/fiber-media-converter\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fiber media converter \u2013 how to choose the right one\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/en\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fiber media converter \u2013 how to choose the right one | SCN","description":"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/","og_locale":"en_US","og_type":"article","og_title":"Fiber media converter \u2013 how to choose the right one | SCN","og_description":"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.","og_url":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:29:29+00:00","og_image":[{"width":1520,"height":490,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f1-en.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/","url":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/","name":"Fiber media converter \u2013 how to choose the right one | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f1-en.webp","datePublished":"2026-10-24T17:27:02+00:00","dateModified":"2026-10-24T17:29:29+00:00","description":"Fiber media converter guide: when fiber beats copper, single-mode or multimode, SFP, reach and what industrial environments require.","breadcrumb":{"@id":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f1-en.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-mediaomvandlare-f1-en.webp","width":1520,"height":490,"caption":"A pair of media converters extends an Ethernet link: copper up to 100 metres, fiber between building A and B, then copper to a camera, I\/O or PLC"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/en\/guides\/fiber-media-converter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/en\/"},{"@type":"ListItem","position":2,"name":"Fiber media converter \u2013 how to choose the right one"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/en\/#website","url":"https:\/\/scn.eu\/en\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/scn.eu\/en\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/scn.eu\/en\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide\/8234153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide\/8234153\/revisions"}],"predecessor-version":[{"id":8234208,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/scn_guide\/8234153\/revisions\/8234208"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/media\/8234056"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/en\/wp-json\/wp\/v2\/media?parent=8234153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}