Products

Solution areas

Product categories

Brands

  • SM 323-1BH01

    SM 323-1BH01

    8x DI 8x DO DC 24 V 1 A For 20 pole front connector

    8x DI 8x DO DC 24 V 1 A For 20 pole front connector

  • SM 323-1BL00

    SM 323-1BL00

    16x DI 16x DO DC 24 V 1 A For 40 pole front connector

    16x DI 16x DO DC 24 V 1 A For 40 pole front connector

  • SM 323-1BL00-S

    SM 323-1BL00-S

    16x DI 16x DO DC 24 V 1 A Safe shutdown according to EN ISO 13849-1 to category 3 PLd For

    16x DI 16x DO DC 24 V 1 A Safe shutdown according to EN ISO 13849-1 to category 3 PLd For 40 pole front connector

  • SM 3231BH70

    SM 3231BH70

    16x DIO SPEED-Bus DC 24 V 0.5 A 100 kHz For 20 pole front connector

    16x DIO SPEED-Bus DC 24 V 0.5 A 100 kHz For 20 pole front connector

  • SM 331-1KF01

    SM 331-1KF01

    8x AI 13 Bit Voltage +/- 10 V, +/- 50 mV, +/- 500 mV, +/- 5 V, 0 V … +10 V Strom +/-

    8x AI 13 Bit Voltage +/- 10 V, +/- 50 mV, +/- 500 mV, +/- 5 V, 0 V … +10 V Strom +/- 20 mA, 0/4…20 mA Resistance thermometer For 40 pole front connector

  • SM 331-7AF70

    SM 331-7AF70

    8x fast AI 16 Bit Current +/- 20 mA Potential isolation between the channels 25 μs…

    8x fast AI 16 Bit Current +/- 20 mA Potential isolation between the channels 25 μs…1000 μs sampling rate (parameterizable) Memory: 8192 value/channel Oscilloscope-/FIFO-Function Alarm parameterizable For 20 pole front connectors

  • SM 331-7BF70

    SM 331-7BF70

    8x fast AI 16 Bit Voltage +/- 10 V Potential isolation between the channels 25 μs…1

    8x fast AI 16 Bit Voltage +/- 10 V Potential isolation between the channels 25 μs…1000 μs sampiling rate (parameterizable) Memory: 8192 value/channel Oscilloscope-/FIFO-Function Alarm parameterizable For 20 pole front connectors

  • SM 331-7KB01

    SM 331-7KB01

    2x AI, in 1 group 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 m

    2x AI, in 1 group 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 mA Resistance thermometer, thermocouple For 20 pole front connectors

  • SM 332-5HB01

    SM 332-5HB01

    2x AO 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 mA Parameteri

    2x AO 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 mA Parameterizable For 20 pole front connectors

  • SM 332-5HD01

    SM 332-5HD01

    4x AO 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 mA Parameteri

    4x AO 12 Bit Voltage +/- 10 V, 1…5 V, 0…10 V Current +/- 20 mA, 0/4…20 mA Parameterizable For 20 pole front connectors

  • SM 334-0KE00

    SM 334-0KE00

    4x AI 2x AO 12 Bit Input: RTD / output voltage 0…10 V Parameterizable For 20 pole fr

    4x AI 2x AO 12 Bit Input: RTD / output voltage 0…10 V Parameterizable For 20 pole front connector

  • SM-1000-003

    SM-1000-003

    Supplied with No. 20 contacts and No. 20 crimp. Weight 7g max. Used in conjunction with MT

    Supplied with No. 20 contacts and No. 20 crimp. Weight 7g max. Used in conjunction with MT-3000-003.

  • SM-1001-003

    SM-1001-003

    Supplied with No. 20 contacts and No. 20 crimp. Weight 14g max. Used in conjunction with M

    Supplied with No. 20 contacts and No. 20 crimp. Weight 14g max. Used in conjunction with MT-3000-003.

  • SM-1002-003

    SM-1002-003

    Weight 14g max. Used in conjunction with MT-3000-003. Supplied with No. 20 contacts and No

    Weight 14g max. Used in conjunction with MT-3000-003. Supplied with No. 20 contacts and No. 20 crimp.

  • Small Dimension  Pancake slip ring

    Small Dimension Pancake slip ring

    This range of slip rings has been designed primarily for the transmission of signals, but

    This range of slip rings has been designed primarily for the transmission of signals, but has now been developed to accommodate power transmission also. Fine brass rings are used for signals and can be plated with silver, gold or rhodium where low contact resistance and low noise levels are required. The best results are obtained…

  • Smart Alarms 900 Series

    Smart Alarms 900 Series

    ECCO’s range of Smart Alarms® were the world’s first self-adjusting back-up alarms. S

    ECCO’s range of Smart Alarms® were the world’s first self-adjusting back-up alarms. Smart Alarms constantly measure ambient noise and adjust their sound level, creating a volume that is safe without being annoying or contributing to noise pollution. Smart Alarms eliminate the need for constant manual adjustment and help prevent intentional alarm disconnection.

  • SMB8650510 Solid State Relay  30A

    SMB8650510 Solid State Relay 30A

    SMB8650510 Switching current: 3x30A AC51 (resistive) / 3x12A AC53 (motor) Switching voltag

    SMB8650510 Switching current: 3x30A AC51 (resistive) / 3x12A AC53 (motor) Switching voltage: 24-520VAC Peak: 70A / 1600V Control voltage: 4-30VDC

  • SMB8670910 Solde state Relay  40A

    SMB8670910 Solde state Relay 40A

    SMB8670910 Switching current: 3x40A AC51 (resistive) / 3x16A AC53 (motor) Switching voltag

    SMB8670910 Switching current: 3x40A AC51 (resistive) / 3x16A AC53 (motor) Switching voltage: 150-520VAC Peak: 75A / 1600V Control voltage: 4-30VDC

  • SMB8850210 Solid State Relay  30A

    SMB8850210 Solid State Relay 30A

    SMB8850210 Switching current: 3x30A AC51 (resistive) / 3x12A AC53 (motor) Switching voltag

    SMB8850210 Switching current: 3x30A AC51 (resistive) / 3x12A AC53 (motor) Switching voltage: 24-640VAC Peak: 70A / 1600V Control voltage: 4-30VDC

  • SNAKPAK Magnetic Circuit Protectors

    SNAKPAK Magnetic Circuit Protectors

    The SNAPAK® series is a snap-acting hydraulic-magnetic circuit protector that combines po

    The SNAPAK® series is a snap-acting hydraulic-magnetic circuit protector that combines power switching and accurate, reliable circuit protection in one aesthetically pleasing package. The SNAPAK® combines the functions of three separate components: power switch, fuse and fuse holder. To the OEM, this means that only one item has to be mounted instead of three. Less…

  • SNE4004K

    SNE4004K

    Output expansion – 4 enables – 3 indicators

    Output expansion – 4 enables – 3 indicators

  • SNO4003K

    SNO4003K

    Base device: – single-channel activation in the supply. – circuit automatic and manual

    Base device: – single-channel activation in the supply. – circuit automatic and manual Reset. – with Reset button monitoring. – 3 enables – 1 indicator

  • SNO4062K

    SNO4062K

    Base device – single-channel or two-channel activation – automatic and manual Reset wi

    Base device – single-channel or two-channel activation – automatic and manual Reset with Reset button monitoring – short-circuit detection – 2 enables – 1 indicator

  • SNO4063K

    SNO4063K

    Base device – single-channel or two-channel activation – automatic and manual Reset â€

    Base device – single-channel or two-channel activation – automatic and manual Reset – with Reset button monitoring – cross monitoring – 3 enables

  • SNZ4052K

    SNZ4052K

    Base device – two-channel activation; 2x NC/NO start inhibit – cross monitoring – sy

    Base device – two-channel activation; 2x NC/NO start inhibit – cross monitoring – synchronous time monitoring – 2 enables – 1 indicator