{"id":8234574,"date":"2026-10-24T17:29:47","date_gmt":"2026-10-24T17:29:47","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234574"},"modified":"2026-10-24T17:29:48","modified_gmt":"2026-10-24T17:29:48","slug":"medicinsk-panel-pc","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/","title":{"rendered":"Medicinsk panel-PC \u2013 IEC 60601-1 og PC&#8217;er p\u00e5 hospitalet"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>Medicinsk panel-PC \u2013 IEC 60601-1 og PC&#x27;er p\u00e5 hospitalet<\/h1>\n<p class=\"g-lead\">En computer ved patientens seng skal v\u00e6re elsikker, t\u00e5le daglig desinfektion og m\u00e5 ikke forstyrre andet medicinsk udstyr. Her gennemg\u00e5r vi, hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver \u2013 og hvorn\u00e5r en almindelig computer er nok.<\/p>\n<div class=\"g-short\"><b class=\"t\">Kort svar<\/b><\/p>\n<ul>\n<li><b>IEC 60601-1<\/b> \u2013 sikkerhedsstandarden for medicinsk elektrisk udstyr: isolation, l\u00e6kstr\u00f8mme og beskyttelse af patient og personale.<\/li>\n<li><b>IEC 60601-1-2<\/b> \u2013 EMC: Udstyret m\u00e5 ikke forstyrre andet medicinsk udstyr og skal t\u00e5le forstyrrelser, for eksempel fra mobiltelefoner.<\/li>\n<li><b>Patientmilj\u00f8et<\/b> \u2013 cirka 1,5 meter omkring patienten. Her g\u00e6lder strengere krav, ogs\u00e5 for computere, der ikke er medicinsk udstyr.<\/li>\n<li><b>Hygiejne<\/b> \u2013 t\u00e6t front, glatte overflader og materialer, der t\u00e5ler hospitalets desinfektionsmidler.<\/li>\n<li><b>En certificeret computer er ikke det samme som medicinsk udstyr<\/b> \u2013 ansvaret efter MDR ligger hos den, der fremstiller slutproduktet.<\/li>\n<\/ul>\n<\/div>\n<h2>Hvorfor kr\u00e6ves der s\u00e6rlige computere t\u00e6t p\u00e5 patienten?<\/h2>\n<p>Almindelige computere og sk\u00e6rme er bygget efter IEC 62368-1, standarden for IT-udstyr. Det er nok i receptionen og p\u00e5 kontoret. T\u00e6t p\u00e5 patienten er foruds\u00e6tningerne anderledes. Patienten kan v\u00e6re tilsluttet andet udstyr, v\u00e6re ude af stand til at reagere eller have nedsat hudmodstand. Overfladerne t\u00f8rres af med st\u00e6rke midler flere gange om dagen, og computeren st\u00e5r ved siden af overv\u00e5gningsudstyr, der ikke m\u00e5 forstyrres.<\/p>\n<p>Derfor stiller sundhedsv\u00e6senet krav om lavere l\u00e6kstr\u00f8mme, bedre isolation, mere modstandsdygtige overflader og kontrolleret EMC. En medicinsk panel-PC er bygget til netop det \u2013 og er ofte ventilatorl\u00f8s og lydl\u00f8s.<\/p>\n<h2>Hvad kr\u00e6ver IEC 60601-1 og IEC 60601-1-2?<\/h2>\n<h3>Elsikkerhed: MOOP og MOPP<\/h3>\n<p>IEC 60601-1 (EN 60601-1 i Europa) er grundstandarden for sikkerhed i medicinsk elektrisk udstyr. Den g\u00e6ldende udgave er tredje udgave med till\u00e6g fra 2012 og 2020. Standarden skelner mellem beskyttelse af operat\u00f8ren, MOOP (<i>Means of Operator Protection<\/i>), og beskyttelse af patienten, MOPP (<i>Means of Patient Protection<\/i>). MOPP er strengest, med h\u00f8jere pr\u00f8vesp\u00e6nding og l\u00e6ngere krybeafstand.<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Beskyttelsesniveau<\/th>\n<th>Pr\u00f8vesp\u00e6nding<\/th>\n<th>Krybeafstand ved 240 V<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">1 \u00d7 MOOP<\/td>\n<td>1 500 V AC<\/td>\n<td>2,5 mm<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">2 \u00d7 MOOP<\/td>\n<td>3 000 V AC<\/td>\n<td>5 mm<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">1 \u00d7 MOPP<\/td>\n<td>1 500 V AC<\/td>\n<td>4 mm<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">2 \u00d7 MOPP<\/td>\n<td>4 000 V AC<\/td>\n<td>8 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Standarden begr\u00e6nser ogs\u00e5 l\u00e6kstr\u00f8mmene. Ber\u00f8ringsstr\u00f8mmen fra kabinettet m\u00e5 for eksempel h\u00f8jst v\u00e6re 100 \u00b5A i normal tilstand og 500 \u00b5A ved en enkelt fejl, som en afbrudt beskyttelsesjord. Almindeligt IT-udstyr kan have l\u00e6kstr\u00f8mme i beskyttelsesjorden p\u00e5 flere milliampere.<\/p>\n<h3>EMC efter IEC 60601-1-2<\/h3>\n<p>IEC 60601-1-2 omhandler elektromagnetisk kompatibilitet. Den g\u00e6ldende version er udgave 4.1 fra 2020. Kravene tager udgangspunkt i, hvor udstyret bruges: professionelle sundhedsfaciliteter, pleje i hjemmet eller s\u00e6rlige milj\u00f8er. Hjemmemilj\u00f8et har h\u00f8jere immunitetskrav, og standarden kr\u00e6ver test mod n\u00e6rliggende radiosendere som telefoner og tablets. Ogs\u00e5 medicinske tastaturer og mus testes ofte efter den.<\/p>\n<h2>Patientmilj\u00f8et og skilletransformere<\/h2>\n<p>IEC 60601-1 definerer patientmilj\u00f8et som det omr\u00e5de, hvor patienten kan komme i kontakt med udstyr, direkte eller via en anden person. I praksis er det cirka 1,5 meter omkring sengen eller briksen og op til 2,5 meters h\u00f8jde.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f1-da.webp\" alt=\"Patientmilj\u00f8et str\u00e6kker sig cirka 1,5 meter omkring sengen og op til 2,5 meters h\u00f8jde. En medicinsk panel-PC efter IEC 60601-1 st\u00e5r inden for zonen, en kontor-PC efter IEC 62368-1 st\u00e5r uden for.\" width=\"1520\" height=\"600\" loading=\"lazy\" decoding=\"async\"><figcaption>Patientmilj\u00f8et efter IEC 60601-1. Inden for zonen g\u00e6lder strengere krav til l\u00e6kstr\u00f8m.<\/figcaption><\/figure>\n<p>N\u00e5r en almindelig computer forbindes med medicinsk udstyr, via kabel eller samme stikd\u00e5se, opst\u00e5r der et medicinsk elektrisk system efter afsnit 16 i IEC 60601-1. Hele systemet skal s\u00e5 opfylde kravene i patientmilj\u00f8et. Det kan l\u00f8ses p\u00e5 to m\u00e5der. Enten v\u00e6lger du en computer, der er certificeret efter IEC 60601-1, eller ogs\u00e5 forsyner du den almindelige computer via en medicinsk skilletransformer og isolerer netv\u00e6rkskablet med en netv\u00e6rksisolator. Hospitalets medicotekniske afdeling afg\u00f8r, hvilken l\u00f8sning der g\u00e6lder.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f2-da.webp\" alt=\"Blokdiagram: En almindelig computer i patientmilj\u00f8et forsynes via en medicinsk skilletransformer og tilsluttes hospitalets netv\u00e6rk via en netv\u00e6rksisolator.\" width=\"1520\" height=\"460\" loading=\"lazy\" decoding=\"async\"><figcaption>En almindelig computer i patientmilj\u00f8et kan isoleres med skilletransformer og netv\u00e6rksisolator.<\/figcaption><\/figure>\n<h2>Hygiejne: t\u00e6t front og modstandsdygtige overflader<\/h2>\n<p>En panel-PC i sundhedsv\u00e6senet t\u00f8rres af mange gange om dagen. Se efter en front med IP65 eller IP66 og en helt plan glasflade uden kanter, hvor snavs kan samle sig. Projiceret kapacitiv ber\u00f8ringssk\u00e6rm (PCAP) fungerer ofte med handsker og er nem at t\u00f8rre af. Ventilatorl\u00f8se computere hvirvler ikke luft og st\u00f8v rundt.<\/p>\n<p>Sp\u00f8rg producenten, hvilke desinfektionsmidler og koncentrationer kabinettet er testet med, for eksempel alkohol, kvatern\u00e6re ammoniumforbindelser, hydrogenperoxid eller klorforbindelser. Nogle kabinetter er antibakterielt behandlet. Det mindsker v\u00e6ksten af bakterier p\u00e5 overfladen, men erstatter aldrig reng\u00f8ring. Tastaturer og mus i silikone med IP68 og tastel\u00e5s til reng\u00f8ring g\u00f8r det nemmere at holde hele arbejdspladsen ren.<\/p>\n<h2>Medicinsk udstyr eller ej?<\/h2>\n<p>Efter EU&#8217;s forordning om medicinsk udstyr, MDR (EU) 2017\/745, er det producentens erkl\u00e6rede form\u00e5l, der afg\u00f8r, om noget er medicinsk udstyr. En panel-PC, der bruges til journaler eller p\u00e5 et sygeplejekontor, er som regel ikke medicinsk udstyr, selv om den er certificeret efter IEC 60601-1. Certificeringen viser, at computeren er elsikker og EMC-testet til sundhedsmilj\u00f8er.<\/p>\n<p>Bygger du dit eget produkt, hvor computeren indg\u00e5r, for eksempel et ultralyds- eller endoskopisystem, er det dig som producent, der har ansvaret for MDR, risikoanalyse og dokumentation. En certificeret computer g\u00f8r arbejdet nemmere, men erstatter det ikke. Software kan ogs\u00e5 i sig selv v\u00e6re medicinsk udstyr. F\u00e5 hj\u00e6lp fra en regulatorisk ekspert til din vurdering.<\/p>\n<h2>Hvor bruges medicinske computere?<\/h2>\n<ul>\n<li><b>Sengeafsnit<\/b> \u2013 sengeterminaler til patientinformation og underholdning, journal ved sengen og sygeplejekontorer.<\/li>\n<li><b>Operation og intensiv<\/b> \u2013 panel-PC&#8217;er indbygget i v\u00e6ggen, computere p\u00e5 vogne med batteri og sk\u00e6rme til kirurgisk video.<\/li>\n<li><b>Billeddiagnostik og laboratorier<\/b> \u2013 computere med grafikkort til billedbehandling og AI, medicinske sk\u00e6rme.<\/li>\n<li><b>Medicoindustrien<\/b> \u2013 computere, der bygges ind i ultralyd, endoskopi og analyseinstrumenter.<\/li>\n<li><b>Ambulancer og hjemmepleje<\/b> \u2013 medicinske tablets og mobile arbejdsstationer.<\/li>\n<\/ul>\n<h2>Fem faldgruber<\/h2>\n<ol class=\"g-pit\">\n<li><b>Almindelig stikd\u00e5se.<\/b> En almindelig stikd\u00e5se fra byggemarkedet h\u00f8rer ikke hjemme i et medicinsk elektrisk system. Brug en skilletransformer eller en godkendt stikd\u00e5se.<\/li>\n<li><b>Kun computeren er certificeret.<\/b> Sk\u00e6rm, str\u00f8mforsyning og tilbeh\u00f8r i patientmilj\u00f8et skal ogs\u00e5 opfylde kravene.<\/li>\n<li><b>Moduler tilf\u00f8jes bagefter.<\/b> Et nyt Wi-Fi- eller 4G-modul kan \u00e6ndre EMC-egenskaberne. Kontroll\u00e9r, at konfigurationen er testet.<\/li>\n<li><b>Forkert desinfektionsmiddel.<\/b> St\u00e6rke midler kan g\u00f8re plast sk\u00f8rt og skade sk\u00e6rmens bel\u00e6gning. F\u00f8lg producentens liste.<\/li>\n<li><b>Certifikatet tolkes som CE-m\u00e6rkning efter MDR.<\/b> IEC 60601-1 dokumenterer elsikkerhed, ikke at produktet er medicinsk udstyr.<\/li>\n<\/ol>\n<h2>Medicinske computere hos SCN<\/h2>\n<p>Vi har medicinske panel-PC&#8217;er, box-PC&#8217;er og sk\u00e6rme fra blandt andre IEI, Baaske Medical, Onyx Healthcare og Axiomtek samt hygiejnetastaturer og mus fra Indukey. Produktsiderne angiver, hvilke standarder det enkelte produkt er certificeret efter.<\/p>\n<h3>Eksempler fra vores sortiment<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/da\/vare\/accel-a2720-da\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/onyx-healthcare-accel-a2720-main.webp\" alt=\"Onyx Healthcare ACCEL-A2720 27&quot; 4K medicinsk AI alt-i-\u00e9n-pc\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Onyx Healthcare<\/span><span class=\"g-pn\">ACCEL-A2720 27&quot; 4K medicinsk AI alt-i-\u00e9n-pc<\/span><span class=\"g-pw\">27&#8243; 4K alt-i-\u00e9n-computer med IP65-front og NVIDIA-grafik til endoskopi og kirurgisk visualisering.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/da\/vare\/e-medic-silence-tp-22p-tp-24p-da\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/baaske-e-medic-silence-tp-22p-tp-24p-main.webp\" alt=\"Baaske Medical e-medic Silence TP-22P\/TP-24P medicinsk panel-pc\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Baaske Medical<\/span><span class=\"g-pn\">e-medic Silence TP-22P\/TP-24P medicinsk panel-pc<\/span><span class=\"g-pw\">T\u00e6t, ventilatorl\u00f8s panel-PC til operationsstuer og intensivafsnit med IP65-front og IP54-bagside.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/da\/vare\/tkg-110-gcq-med-ip68-backl-white-medical-keyboard-da\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/indukey-tkg-110-gcq-med-ip68-backl-white-usb-xx-main.webp\" alt=\"Indukey TKG-110-GCQ-MED-IP68-BACKL-WHITE hospitalstastatur\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Indukey<\/span><span class=\"g-pn\">TKG-110-GCQ-MED-IP68-BACKL-WHITE hospitalstastatur<\/span><span class=\"g-pw\">Vaskbart IP68-tastatur i silikone med tastel\u00e5s til reng\u00f8ring, certificeret efter IEC 60601-1-2.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/industrial-computers-da\/panel-pc-da\/medical-panel-pc-da\/\">Medicinske panel-PC&#x27;er<\/a><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/industrial-computers-da\/box-pc-da\/medical-pc-da\/\">Medicinske computere<\/a><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/industrial-computers-da\/displays-da\/medical-displays-da\/\">Medicinske sk\u00e6rme<\/a><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/industrial-computers-da\/medicinske-tastaturer-og-mus-da\/\">Medicinske tastaturer og mus<\/a><\/div>\n<div class=\"g-cta\">\n<p>Skal du v\u00e6lge en computer til et sundhedsmilj\u00f8 eller til dit eget medicinske produkt? Sp\u00f8rg en af vores ingeni\u00f8rer \u2013 du f\u00e5r svar inden for 24 timer.<\/p>\n<p><a href=\"https:\/\/scn.eu\/da\/kontakt\/\">Sp\u00f8rg en ingeni\u00f8r<\/a><\/div>\n<h2>Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\n<details>\n<summary>Hvad er IEC 60601-1?<\/summary>\n<p>Den internationale grundstandard for sikkerhed i medicinsk elektrisk udstyr. Den stiller krav til isolation, l\u00e6kstr\u00f8mme, temperatur og mekanisk sikkerhed.<\/p>\n<\/details>\n<details>\n<summary>Hvad er forskellen p\u00e5 MOOP og MOPP?<\/summary>\n<p>MOOP beskytter operat\u00f8ren, MOPP beskytter patienten. MOPP kr\u00e6ver h\u00f8jere pr\u00f8vesp\u00e6nding og l\u00e6ngere krybeafstand, fordi patienten kan v\u00e6re mere udsat.<\/p>\n<\/details>\n<details>\n<summary>Skal en computer i sundhedsv\u00e6senet v\u00e6re certificeret efter IEC 60601-1?<\/summary>\n<p>Ikke altid. Uden for patientmilj\u00f8et er IEC 62368-1 normalt nok. Inden for patientmilj\u00f8et kr\u00e6ves enten en IEC 60601-1-certificeret computer eller ekstra beskyttelse som en skilletransformer.<\/p>\n<\/details>\n<details>\n<summary>Er en medicinsk panel-PC medicinsk udstyr?<\/summary>\n<p>Som regel ikke i sig selv. Det afg\u00f8res af det erkl\u00e6rede form\u00e5l efter MDR. Certificeringen efter IEC 60601-1 viser, at computeren er elsikker i sundhedsmilj\u00f8er.<\/p>\n<\/details>\n<details>\n<summary>Hvad regnes som patientmilj\u00f8?<\/summary>\n<p>Det omr\u00e5de, hvor patienten kan komme i kontakt med udstyr, direkte eller via en anden person. I praksis cirka 1,5 meter omkring patienten og op til 2,5 meters h\u00f8jde.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>En computer ved patientens seng skal v\u00e6re elsikker, t\u00e5le daglig desinfektion og m\u00e5 ikke forstyrre andet medicinsk udstyr. Her gennemg\u00e5r vi, hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver \u2013 og hvorn\u00e5r en almindelig computer er nok.<\/p>\n","protected":false},"author":11,"featured_media":8234531,"template":"","meta":{"_yoast_wpseo_focuskw":"medicinsk panel pc","_yoast_wpseo_metadesc":"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[854,810,12261,11501],"_scn_guide_sectors":[1114],"_scn_guide_type":"industry","_scn_guide_order":68,"footnotes":""},"class_list":["post-8234574","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Medicinsk panel-PC \u2013 IEC 60601-1 og PC&#039;er p\u00e5 hospitalet | SCN<\/title>\n<meta name=\"description\" content=\"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Medicinsk panel-PC \u2013 IEC 60601-1 og PC&#039;er p\u00e5 hospitalet | SCN\" \/>\n<meta property=\"og:description\" content=\"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:29:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f1-da.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/\",\"name\":\"Medicinsk panel-PC \u2013 IEC 60601-1 og PC'er p\u00e5 hospitalet | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-vard-f1-da.webp\",\"datePublished\":\"2026-10-24T17:29:47+00:00\",\"dateModified\":\"2026-10-24T17:29:48+00:00\",\"description\":\"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-vard-f1-da.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-vard-f1-da.webp\",\"width\":1520,\"height\":600,\"caption\":\"Patientmilj\u00f8et str\u00e6kker sig cirka 1,5 meter omkring sengen og op til 2,5 meters h\u00f8jde. En medicinsk panel-PC efter IEC 60601-1 st\u00e5r inden for zonen, en kontor-PC efter IEC 62368-1 st\u00e5r uden for.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/medicinsk-panel-pc\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/da\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Medicinsk panel-PC \u2013 IEC 60601-1 og PC&#8217;er p\u00e5 hospitalet\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/da\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/da\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/da\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Medicinsk panel-PC \u2013 IEC 60601-1 og PC'er p\u00e5 hospitalet | SCN","description":"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/","og_locale":"da_DK","og_type":"article","og_title":"Medicinsk panel-PC \u2013 IEC 60601-1 og PC'er p\u00e5 hospitalet | SCN","og_description":"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.","og_url":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:29:48+00:00","og_image":[{"width":1520,"height":600,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f1-da.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimeret l\u00e6setid":"7 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/","url":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/","name":"Medicinsk panel-PC \u2013 IEC 60601-1 og PC'er p\u00e5 hospitalet | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/da\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f1-da.webp","datePublished":"2026-10-24T17:29:47+00:00","dateModified":"2026-10-24T17:29:48+00:00","description":"Medicinsk panel-PC: hvad IEC 60601-1 og IEC 60601-1-2 kr\u00e6ver, MOOP og MOPP, l\u00e6kstr\u00f8m, patientmilj\u00f8, hygiejne, og hvorn\u00e5r en almindelig PC er nok.","breadcrumb":{"@id":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f1-da.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-vard-f1-da.webp","width":1520,"height":600,"caption":"Patientmilj\u00f8et str\u00e6kker sig cirka 1,5 meter omkring sengen og op til 2,5 meters h\u00f8jde. En medicinsk panel-PC efter IEC 60601-1 st\u00e5r inden for zonen, en kontor-PC efter IEC 62368-1 st\u00e5r uden for."},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/da\/guider\/medicinsk-panel-pc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/da\/"},{"@type":"ListItem","position":2,"name":"Medicinsk panel-PC \u2013 IEC 60601-1 og PC&#8217;er p\u00e5 hospitalet"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/da\/#website","url":"https:\/\/scn.eu\/da\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/da\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/da\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/scn.eu\/da\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/da\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/scn.eu\/da\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/da\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide\/8234574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide\/8234574\/revisions"}],"predecessor-version":[{"id":8235298,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide\/8234574\/revisions\/8235298"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/media\/8234531"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/media?parent=8234574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}