{"id":8234570,"date":"2026-10-24T17:28:56","date_gmt":"2026-10-24T17:28:56","guid":{"rendered":"https:\/\/scn.eu\/?post_type=scn_guide&#038;p=8234570"},"modified":"2026-10-24T17:29:41","modified_gmt":"2026-10-24T17:29:41","slug":"iec-62443-nis2","status":"publish","type":"scn_guide","link":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/","title":{"rendered":"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk"},"content":{"rendered":"<div class=\"scn-guide\">\n<h1>IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk<\/h1>\n<p class=\"g-lead\">Styresystemer og industrielle netv\u00e6rk er i dag m\u00e5l for angreb, og med NIS2 er cybersikkerhed blevet et lovkrav for mange virksomheder. Her forklarer vi IEC 62443, hvad NIS2 indeb\u00e6rer, og hvilke f\u00f8rste skridt der giver st\u00f8rst effekt i et OT-netv\u00e6rk.<\/p>\n<div class=\"g-short\"><b class=\"t\">Kort svar<\/b><\/p>\n<ul>\n<li><b>IEC 62443<\/b> \u2013 standardserien for cybersikkerhed i industrielle styresystemer (OT). Den stiller krav til anl\u00e6gsejere, integratorer og produktleverand\u00f8rer.<\/li>\n<li><b>Zoner og conduits<\/b> \u2013 opdel netv\u00e6rket i zoner efter risiko, og kontroll\u00e9r al trafik mellem dem.<\/li>\n<li><b>SL 1\u20134<\/b> \u2013 sikkerhedsniveauerne angiver, hvilken slags angriber beskyttelsen skal kunne modst\u00e5.<\/li>\n<li><b>NIS2<\/b> \u2013 EU-direktiv, der kr\u00e6ver risikostyring og h\u00e6ndelsesrapportering af mellemstore og store virksomheder i udpegede sektorer. I Danmark g\u00e6lder NIS2-loven siden 1. juli 2025.<\/li>\n<li><b>Start med<\/b> \u2013 kortl\u00e6gning, segmentering, sikker fjernadgang og en plan for opdateringer.<\/li>\n<\/ul>\n<\/div>\n<h2>Hvorfor OT-sikkerhed adskiller sig fra IT-sikkerhed<\/h2>\n<p>I kontorets IT-systemer kommer fortroligheden ofte f\u00f8rst. I et styresystem er det tilg\u00e6ngeligheden og sikkerheden for mennesker og maskiner, der betyder mest: Processen m\u00e5 ikke stoppe, og en ventil m\u00e5 ikke \u00e5bnes af den forkerte person. Udstyret sidder ofte i 15\u201330 \u00e5r, opdateringer kr\u00e6ver planlagte stop, og \u00e6ldre protokoller som Modbus har ingen autentificering. Samtidig bliver flere og flere maskiner koblet p\u00e5 nettet for at f\u00e5 fjernservice.<\/p>\n<div class=\"g-short\">\n<p style=\"margin:0\">Guiden er et teknisk overblik og ikke juridisk r\u00e5dgivning. Hvilke krav der g\u00e6lder for din virksomhed, afg\u00f8res af lovgivningen i dit land og af den kompetente myndighed.<\/p>\n<\/div>\n<h2>Hvad er IEC 62443?<\/h2>\n<p>IEC 62443 er en serie internationale standarder for cybersikkerhed i industrielle automations- og styresystemer. Den bygger p\u00e5 arbejde i den amerikanske organisation ISA, og derfor ser du nogle gange navnet ISA\/IEC 62443. Serien er inddelt i fire grupper: generelt, politikker og procedurer, systemer og komponenter.<\/p>\n<div class=\"g-tbl\">\n<table>\n<thead>\n<tr>\n<th>Del<\/th>\n<th>Indhold<\/th>\n<th>Henvender sig til<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"n\">62443-2-1<\/td>\n<td>Sikkerhedsprogram for drift og vedligehold<\/td>\n<td>Anl\u00e6gsejere<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">62443-2-4<\/td>\n<td>Sikkerhedskrav til integratorer og serviceleverand\u00f8rer<\/td>\n<td>Integratorer<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">62443-3-2<\/td>\n<td>Risikovurdering, zoner og conduits<\/td>\n<td>Anl\u00e6gsejere og integratorer<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">62443-3-3<\/td>\n<td>Sikkerhedskrav og sikkerhedsniveauer for systemer<\/td>\n<td>Integratorer<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">62443-4-1<\/td>\n<td>Sikker produktudviklingsproces<\/td>\n<td>Produktleverand\u00f8rer<\/td>\n<\/tr>\n<tr>\n<td class=\"n\">62443-4-2<\/td>\n<td>Tekniske sikkerhedskrav til komponenter<\/td>\n<td>Produktleverand\u00f8rer<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3>Tre roller<\/h3>\n<p>Anl\u00e6gsejeren ejer og driver anl\u00e6gget og har ansvaret for risiciene. Integratoren konstruerer, bygger og vedligeholder systemet. Produktleverand\u00f8ren udvikler komponenterne, for eksempel switche, routere, PLC&#8217;er og software.<\/p>\n<h3>Sikkerhedsniveauer SL 1\u20134<\/h3>\n<ul>\n<li><b>SL 1<\/b> \u2013 beskyttelse mod utilsigtede fejl og tilf\u00e6ldige overtr\u00e6delser.<\/li>\n<li><b>SL 2<\/b> \u2013 beskyttelse mod bevidste angreb med enkle midler, sm\u00e5 ressourcer og almen viden.<\/li>\n<li><b>SL 3<\/b> \u2013 beskyttelse mod avancerede angreb med moderate ressourcer og viden om styresystemer.<\/li>\n<li><b>SL 4<\/b> \u2013 beskyttelse mod avancerede angreb med store ressourcer og h\u00f8j motivation.<\/li>\n<\/ul>\n<h3>Zoner og conduits<\/h3>\n<p>En zone er en gruppe udstyr med de samme sikkerhedskrav, for eksempel en produktionslinje eller en transformerstation. En conduit, p\u00e5 dansk nogenlunde en kommunikationskanal, er den kontrollerede vej mellem zoner, typisk via en firewall eller en sikker router. Tanken er, at et indbrud i \u00e9n zone ikke frit skal kunne sprede sig til resten af anl\u00e6gget.<\/p>\n<figure><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-iec62443-f1-da.webp\" alt=\"Et industrinetv\u00e6rk opdelt i zoner: virksomhedsnetv\u00e6rk, DMZ og produktionsnetv\u00e6rk med to linjer. Firewalls fungerer som conduits mellem zonerne, og leverand\u00f8rens fjernadgang g\u00e5r via en VPN-router til DMZ\" width=\"1520\" height=\"650\" loading=\"lazy\" decoding=\"async\"><figcaption>Zoner og conduits: Hver zone beskyttes af en kontrolleret vej ind, og fjernadgang g\u00e5r kun via DMZ.<\/figcaption><\/figure>\n<h2>Hvad kr\u00e6ver NIS2 \u2013 og hvem er omfattet?<\/h2>\n<p>NIS2, direktiv (EU) 2022\/2555, afl\u00f8ste det f\u00f8rste NIS-direktiv og skulle v\u00e6re gennemf\u00f8rt i EU-landene senest i oktober 2024. Mange lande blev forsinkede. I Danmark er direktivet gennemf\u00f8rt med NIS2-loven, der tr\u00e5dte i kraft 1. juli 2025. Omfattede virksomheder skal registrere sig hos den kompetente myndighed for deres sektor. Andre lande er n\u00e5et forskellige steder til.<\/p>\n<p>Direktivet g\u00e6lder som regel for mellemstore og store virksomheder, fra 50 ansatte eller 10 millioner euro i \u00e5rsoms\u00e6tning, i udpegede sektorer. Det omfatter energi, transport, sundhedsv\u00e6sen, drikkevand, spildevand og digital infrastruktur, men ogs\u00e5 fremstilling af blandt andet medicinsk udstyr, elektronik, elektrisk udstyr, maskiner og k\u00f8ret\u00f8jer samt f\u00f8devarer og kemikalier. Nogle virksomheder er omfattet uanset st\u00f8rrelse.<\/p>\n<ul>\n<li><b>Risikostyring<\/b> \u2013 foranstaltninger for blandt andet h\u00e6ndelsesh\u00e5ndtering, beredskab og kontinuitet, sikkerhed i forsyningsk\u00e6den, adgangskontrol og kryptering.<\/li>\n<li><b>Ledelsens ansvar<\/b> \u2013 ledelsen skal uddannes i sikkerhedsforanstaltningerne og har ansvaret for, at de gennemf\u00f8res.<\/li>\n<li><b>H\u00e6ndelsesrapportering<\/b> \u2013 en tidlig varsling inden for 24 timer, en h\u00e6ndelsesunderretning inden for 72 timer og en endelig rapport inden for en m\u00e5ned.<\/li>\n<li><b>Sanktioner<\/b> \u2013 b\u00f8der p\u00e5 op til 10 millioner euro eller 2 procent af den globale \u00e5rsoms\u00e6tning for v\u00e6sentlige enheder.<\/li>\n<\/ul>\n<p>Ogs\u00e5 virksomheder, der ikke er omfattet, bliver p\u00e5virket, fordi kunder, der er omfattet, skal stille krav til deres leverand\u00f8rer. For producenter af produkter med digitale elementer kommer EU&#8217;s forordning om cyberrobusthed (CRA), forordning (EU) 2024\/2847, oveni. Den g\u00e6lder fuldt ud fra december 2027.<\/p>\n<h2>Praktiske f\u00f8rste skridt<\/h2>\n<ol>\n<li><b>Kortl\u00e6g.<\/b> List udstyr, firmwareversioner og forbindelser. Du kan ikke beskytte det, du ikke ved, at du har.<\/li>\n<li><b>Segment\u00e9r.<\/b> Opdel netv\u00e6rket i zoner med VLAN i managed switche og firewalls imellem. Adskil kontornetv\u00e6rket fra OT-netv\u00e6rket med en DMZ.<\/li>\n<li><b>Kontroll\u00e9r trafikken.<\/b> Industrielle firewalls og sikre routere med deep packet inspection forst\u00e5r protokoller som Modbus og kan stoppe uautoriserede kommandoer, ikke kun porte.<\/li>\n<li><b>Sikr fjernadgangen.<\/b> Ingen \u00e5bne porte mod internettet. Leverand\u00f8rer kobler p\u00e5 via VPN gennem et kontrolleret punkt med personlige konti og tofaktorgodkendelse.<\/li>\n<li><b>Opdat\u00e9r og h\u00e6rd.<\/b> Lav en plan for firmwareopdateringer, skift standardadgangskoder, og luk tjenester og porte, der ikke bruges.<\/li>\n<li><b>Log og overv\u00e5g.<\/b> Saml logs centralt, og giv alarm ved afvigelser, s\u00e5 h\u00e6ndelser opdages i tide.<\/li>\n<li><b>Planl\u00e6g gendannelse.<\/b> Tag backup af konfigurationer og programmer, og test, at gendannelsen virker.<\/li>\n<\/ol>\n<h3>Eksempler fra forskellige brancher<\/h3>\n<ul>\n<li><b>Energi<\/b> \u2013 sikre routere mellem transformerstationer og driftscentral og firewalls, der forst\u00e5r IEC 61850 og DNP3.<\/li>\n<li><b>Vand og spildevand<\/b> \u2013 pumpestationer, der tilg\u00e5s via mobilnettet og VPN i stedet for \u00e5bne porte.<\/li>\n<li><b>Fabrikker og maskinbyggere<\/b> \u2013 NAT-enheder, der adskiller maskinnetv\u00e6rket fra kundens netv\u00e6rk, og VPN-routere til fjernservice.<\/li>\n<li><b>Jernbane<\/b> \u2013 sikre routere og gateways med firewall, der adskiller delsystemerne i toget.<\/li>\n<li><b>Hospitaler og forsvar<\/b> \u2013 medicinsk udstyr i egne zoner og streng adskillelse mellem netv\u00e6rk med forskellig sikkerhedsklassifikation.<\/li>\n<\/ul>\n<h2>Hvad skal du kr\u00e6ve af leverand\u00f8rer?<\/h2>\n<ul>\n<li>Produkter certificeret efter <b>IEC 62443-4-2<\/b> med angivet sikkerhedsniveau, for eksempel SL 2.<\/li>\n<li>At producenten udvikler efter <b>IEC 62443-4-1<\/b> med en dokumenteret proces for sikker udvikling og h\u00e5ndtering af s\u00e5rbarheder.<\/li>\n<li>Besked om, hvor l\u00e6nge der leveres sikkerhedsopdateringer.<\/li>\n<li>Sikre standardindstillinger: ingen f\u00e6lles standardadgangskoder, signeret firmware og secure boot. Gerne ogs\u00e5 en fortegnelse over softwarekomponenterne (SBOM).<\/li>\n<li>For integratorer og servicevirksomheder: arbejdsgange efter <b>IEC 62443-2-4<\/b>.<\/li>\n<\/ul>\n<h2>Almindelige fejl<\/h2>\n<ol class=\"g-pit\">\n<li><b>Et fladt netv\u00e6rk.<\/b> N\u00e5r alt ligger i samme netv\u00e6rk, kan skadelig kode p\u00e5 en servicecomputer n\u00e5 hver eneste PLC. Segmentering er ofte det tiltag, der giver st\u00f8rst effekt.<\/li>\n<li><b>Et air gap, der ikke findes.<\/b> USB-n\u00f8gler, servicecomputere og 4G-modemer, som nogen har sat ind, bryder isoleringen. Kortl\u00e6g alle veje ind.<\/li>\n<li><b>Fjernadgang ved siden af.<\/b> Port\u00e5bninger og fjernstyringsprogrammer fra en hurtig fejls\u00f8gning bliver ofte siddende. Saml al fjernadgang i \u00e9n kontrolleret l\u00f8sning.<\/li>\n<li><b>Certifikatet bliver et alibi.<\/b> En komponent certificeret efter IEC 62443-4-2 g\u00f8r ikke systemet sikkert. Sikkerhedsniveauet afg\u00f8res af, hvordan zoner, conduits og procedurer er udformet.<\/li>\n<\/ol>\n<h2>Sikre netv\u00e6rksprodukter hos SCN<\/h2>\n<p>Vi har sikre routere, industrielle firewalls, NAT-enheder, VPN-routere og managed switche fra blandt andre Moxa, Axiomtek, INSYS icom, HMS Networks og Yaskawa. En del produkter i sortimentet er certificeret efter IEC 62443-4-2, for eksempel Moxas serielle device server NPort 6600-G2 p\u00e5 niveau SL 2.<\/p>\n<h3>Eksempler fra vores sortiment<\/h3>\n<div class=\"g-prod\"><a class=\"g-pc\" href=\"https:\/\/scn.eu\/da\/vare\/edr-g9010-da\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/moxa-edr-g9010-main.webp\" alt=\"Moxa EDR-G9010 10-ports gigabit sikkerhedsrouter\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Moxa<\/span><span class=\"g-pn\">EDR-G9010 10-ports gigabit sikkerhedsrouter<\/span><span class=\"g-pw\">Sikker router med firewall, IPS og deep packet inspection og op til 250 IPsec-tunneler.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/da\/vare\/ina200-da\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/axiomtek-ina200-main.webp\" alt=\"Axiomtek iNA200 OT-cybersikkerhedsgateway til DIN-skinne\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">Axiomtek<\/span><span class=\"g-pn\">iNA200 OT-cybersikkerhedsgateway til DIN-skinne<\/span><span class=\"g-pw\">OT-sikkerhedsgateway til DIN-skinne med TPM 2.0, LAN bypass, SFP-fiberporte og plads til 5G, til \u221240 til 70 \u00b0C.<\/span><\/a><a class=\"g-pc\" href=\"https:\/\/scn.eu\/da\/vare\/mrx-da\/\"><img loading=\"lazy\" src=\"https:\/\/scn.eu\/wp-content\/uploads\/2025\/01\/AF_MRX3_LTE_Basic_600x600_RGB_96dpi__1001658325203.jpeg\" alt=\"INSYS icom MRX3 Modul\u00e6r industriel router\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\"><span class=\"g-pb\">INSYS icom<\/span><span class=\"g-pn\">MRX3 Modul\u00e6r industriel router<\/span><span class=\"g-pw\">Modul\u00e6r industrirouter til sikker fjernadgang til maskiner og kritisk infrastruktur.<\/span><\/a><\/div>\n<div class=\"g-links\"><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/network-products-2\/secure-routers\/\">Sikre routere<\/a><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/network-products-2\/vpn-routers-da\/\">VPN-routere<\/a><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/network-products-2\/ethernet-da\/managed-switches-da\/\">Managed switche<\/a><a href=\"https:\/\/scn.eu\/da\/vare-kategori\/produkter\/network-products-2\/\">Netv\u00e6rksprodukter<\/a><\/div>\n<div class=\"g-cta\">\n<p>Vil du segmentere netv\u00e6rket eller sikre fjernadgangen? Beskriv anl\u00e6gget for vores ingeni\u00f8rer \u2013 du f\u00e5r svar inden for 24 timer.<\/p>\n<p><a href=\"https:\/\/scn.eu\/da\/kontakt\/\">Sp\u00f8rg en ingeni\u00f8r<\/a><\/div>\n<h2>Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\n<details>\n<summary>Er IEC 62443 obligatorisk?<\/summary>\n<p>Standarden i sig selv er frivillig. Men den bruges ofte til at vise, at kravene i NIS2 og den nationale lovgivning er opfyldt, og flere og flere kunder kr\u00e6ver den ved indk\u00f8b.<\/p>\n<\/details>\n<details>\n<summary>Hvad er forskellen p\u00e5 IEC 62443 og ISO\/IEC 27001?<\/summary>\n<p>ISO\/IEC 27001 beskriver et ledelsessystem for informationssikkerhed i hele organisationen. IEC 62443 er skrevet til industrielle styresystemer og stiller tekniske krav til systemer og komponenter. Mange bruger begge.<\/p>\n<\/details>\n<details>\n<summary>Er min virksomhed omfattet af NIS2?<\/summary>\n<p>Det afh\u00e6nger af sektor og st\u00f8rrelse. Tjek lovgivningen i dit land og vejledningen fra den kompetente myndighed, i Danmark blandt andet Styrelsen for Samfundssikkerhed. Ogs\u00e5 virksomheder, der ikke er omfattet, f\u00e5r ofte krav fra kunder, der er.<\/p>\n<\/details>\n<details>\n<summary>Hvad betyder SL 2 i IEC 62443?<\/summary>\n<p>Sikkerhedsniveau 2 betyder beskyttelse mod bevidste angreb med enkle midler og almen viden. Det er et udbredt niveau for certificerede industrielle netv\u00e6rksprodukter.<\/p>\n<\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Styresystemer og industrielle netv\u00e6rk er i dag m\u00e5l for angreb, og med NIS2 er cybersikkerhed blevet et lovkrav for mange virksomheder. Her forklarer vi IEC 62443, hvad NIS2 indeb\u00e6rer, og hvilke f\u00f8rste skridt der giver st\u00f8rst effekt i et OT-netv\u00e6rk.<\/p>\n","protected":false},"author":11,"featured_media":8234277,"template":"","meta":{"_yoast_wpseo_focuskw":"iec 62443","_yoast_wpseo_metadesc":"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.","_kad_post_transparent":"","_kad_post_title":"hide","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"hide","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","_scn_guide_cats":[869,868,871],"_scn_guide_sectors":[10762],"_scn_guide_type":"industry","_scn_guide_order":60,"footnotes":""},"class_list":["post-8234570","scn_guide","type-scn_guide","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk | SCN<\/title>\n<meta name=\"description\" content=\"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk | SCN\" \/>\n<meta property=\"og:description\" content=\"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/\" \/>\n<meta property=\"og:site_name\" content=\"SCN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-24T17:29:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-iec62443-f1-da.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1520\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/\",\"name\":\"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk | SCN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-iec62443-f1-da.webp\",\"datePublished\":\"2026-10-24T17:28:56+00:00\",\"dateModified\":\"2026-10-24T17:29:41+00:00\",\"description\":\"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-iec62443-f1-da.webp\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/scn-guide-iec62443-f1-da.webp\",\"width\":1520,\"height\":650,\"caption\":\"Et industrinetv\u00e6rk opdelt i zoner: virksomhedsnetv\u00e6rk, DMZ og produktionsnetv\u00e6rk med to linjer. Firewalls fungerer som conduits mellem zonerne, og leverand\u00f8rens fjernadgang g\u00e5r via en VPN-router til DMZ\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/guider\\\/iec-62443-nis2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/scn.eu\\\/da\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#website\",\"url\":\"https:\\\/\\\/scn.eu\\\/da\\\/\",\"name\":\"SCN\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/scn.eu\\\/da\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#organization\",\"name\":\"Sensor Control Nordic\",\"alternateName\":\"SCN\",\"url\":\"https:\\\/\\\/scn.eu\\\/da\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"contentUrl\":\"https:\\\/\\\/scn.eu\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/SCN-logo-scaled.png\",\"width\":2560,\"height\":632,\"caption\":\"Sensor Control Nordic\"},\"image\":{\"@id\":\"https:\\\/\\\/scn.eu\\\/da\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/sensor-control-nordic-ab\"],\"location\":[{\"@type\":\"Place\",\"name\":\"SCN Walsall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"46 Hall Lane, Walsall Wood\",\"addressLocality\":\"Walsall\",\"postalCode\":\"WS9 9DP\",\"addressCountry\":\"GB\",\"addressRegion\":\"West Midlands\"},\"telephone\":\"+44 1634 300 900\"},{\"@type\":\"Place\",\"name\":\"SCN Stockholm\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Gustav III:s Boulevard 32\",\"addressLocality\":\"Solna\",\"postalCode\":\"169 73\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 8 668 21 00\"},{\"@type\":\"Place\",\"name\":\"SCN Malm\u00f6\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"R\u00f6nnviksgatan 13\",\"addressLocality\":\"Malm\u00f6\",\"postalCode\":\"213 74\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 40 688 02 00\"},{\"@type\":\"Place\",\"name\":\"SCN Sundsvall\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Trafikgatan 11\",\"addressLocality\":\"Sundsvall\",\"postalCode\":\"856 44\",\"addressCountry\":\"SE\"},\"telephone\":\"+46 60 740 75 81\"},{\"@type\":\"Place\",\"name\":\"SCN Helsinki\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Huopalahdentie 24A\",\"addressLocality\":\"Helsinki\",\"postalCode\":\"00350\",\"addressCountry\":\"FI\"},\"telephone\":\"+358 20 734 8600\"},{\"@type\":\"Place\",\"name\":\"SCN Tallinn\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Narva mnt 5\",\"addressLocality\":\"Tallinn\",\"postalCode\":\"10117\",\"addressCountry\":\"EE\"},\"telephone\":\"+372 651 4550\"},{\"@type\":\"Place\",\"name\":\"SCN Oslo\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Kristoffer Robins vei 13\",\"addressLocality\":\"Oslo\",\"postalCode\":\"0978\",\"addressCountry\":\"NO\"},\"telephone\":\"+47 23 88 89 62\"},{\"@type\":\"Place\",\"name\":\"SCN R\u00f8dekro\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"H\u00e6rvejen 8\",\"addressLocality\":\"R\u00f8dekro\",\"postalCode\":\"6230\",\"addressCountry\":\"DK\"},\"telephone\":\"+45 78 74 65 00\"},{\"@type\":\"Place\",\"name\":\"SCN Madrid\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Paseo de la Castellana, 200\",\"addressLocality\":\"Madrid\",\"postalCode\":\"28046\",\"addressCountry\":\"ES\",\"addressRegion\":\"Comunidad de Madrid\"},\"telephone\":\"+34 93 641 59 97\"},{\"@type\":\"Place\",\"name\":\"SCN Tarnowskie G\u00f3ry\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"ul. Ma\u0142a 1B\",\"addressLocality\":\"Tarnowskie G\u00f3ry\",\"postalCode\":\"42-605\",\"addressCountry\":\"PL\"},\"telephone\":\"+48 511 199 460\"}],\"email\":\"sales@scn.eu\",\"areaServed\":[\"SE\",\"NO\",\"DK\",\"FI\",\"EE\",\"GB\",\"PL\",\"ES\"],\"knowsLanguage\":[\"en\",\"sv\",\"da\",\"fi\",\"nb\",\"et\",\"pl\",\"es\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk | SCN","description":"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/","og_locale":"da_DK","og_type":"article","og_title":"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk | SCN","og_description":"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.","og_url":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/","og_site_name":"SCN","article_modified_time":"2026-10-24T17:29:41+00:00","og_image":[{"width":1520,"height":650,"url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-iec62443-f1-da.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimeret l\u00e6setid":"7 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/","url":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/","name":"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk | SCN","isPartOf":{"@id":"https:\/\/scn.eu\/da\/#website"},"primaryImageOfPage":{"@id":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/#primaryimage"},"image":{"@id":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/#primaryimage"},"thumbnailUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-iec62443-f1-da.webp","datePublished":"2026-10-24T17:28:56+00:00","dateModified":"2026-10-24T17:29:41+00:00","description":"IEC 62443 og NIS2 for industrielle netv\u00e6rk: zoner og conduits, sikkerhedsniveauer SL 1\u20134, hvad NIS2-loven kr\u00e6ver, og praktiske f\u00f8rste skridt.","breadcrumb":{"@id":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/#primaryimage","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-iec62443-f1-da.webp","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/10\/scn-guide-iec62443-f1-da.webp","width":1520,"height":650,"caption":"Et industrinetv\u00e6rk opdelt i zoner: virksomhedsnetv\u00e6rk, DMZ og produktionsnetv\u00e6rk med to linjer. Firewalls fungerer som conduits mellem zonerne, og leverand\u00f8rens fjernadgang g\u00e5r via en VPN-router til DMZ"},{"@type":"BreadcrumbList","@id":"https:\/\/scn.eu\/da\/guider\/iec-62443-nis2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/scn.eu\/da\/"},{"@type":"ListItem","position":2,"name":"IEC 62443 og NIS2 \u2013 cybersikkerhed i industrielle netv\u00e6rk"}]},{"@type":"WebSite","@id":"https:\/\/scn.eu\/da\/#website","url":"https:\/\/scn.eu\/da\/","name":"SCN","description":"","publisher":{"@id":"https:\/\/scn.eu\/da\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/scn.eu\/da\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/scn.eu\/da\/#organization","name":"Sensor Control Nordic","alternateName":"SCN","url":"https:\/\/scn.eu\/da\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/scn.eu\/da\/#\/schema\/logo\/image\/","url":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","contentUrl":"https:\/\/scn.eu\/wp-content\/uploads\/2026\/04\/SCN-logo-scaled.png","width":2560,"height":632,"caption":"Sensor Control Nordic"},"image":{"@id":"https:\/\/scn.eu\/da\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/sensor-control-nordic-ab"],"location":[{"@type":"Place","name":"SCN Walsall","address":{"@type":"PostalAddress","streetAddress":"46 Hall Lane, Walsall Wood","addressLocality":"Walsall","postalCode":"WS9 9DP","addressCountry":"GB","addressRegion":"West Midlands"},"telephone":"+44 1634 300 900"},{"@type":"Place","name":"SCN Stockholm","address":{"@type":"PostalAddress","streetAddress":"Gustav III:s Boulevard 32","addressLocality":"Solna","postalCode":"169 73","addressCountry":"SE"},"telephone":"+46 8 668 21 00"},{"@type":"Place","name":"SCN Malm\u00f6","address":{"@type":"PostalAddress","streetAddress":"R\u00f6nnviksgatan 13","addressLocality":"Malm\u00f6","postalCode":"213 74","addressCountry":"SE"},"telephone":"+46 40 688 02 00"},{"@type":"Place","name":"SCN Sundsvall","address":{"@type":"PostalAddress","streetAddress":"Trafikgatan 11","addressLocality":"Sundsvall","postalCode":"856 44","addressCountry":"SE"},"telephone":"+46 60 740 75 81"},{"@type":"Place","name":"SCN Helsinki","address":{"@type":"PostalAddress","streetAddress":"Huopalahdentie 24A","addressLocality":"Helsinki","postalCode":"00350","addressCountry":"FI"},"telephone":"+358 20 734 8600"},{"@type":"Place","name":"SCN Tallinn","address":{"@type":"PostalAddress","streetAddress":"Narva mnt 5","addressLocality":"Tallinn","postalCode":"10117","addressCountry":"EE"},"telephone":"+372 651 4550"},{"@type":"Place","name":"SCN Oslo","address":{"@type":"PostalAddress","streetAddress":"Kristoffer Robins vei 13","addressLocality":"Oslo","postalCode":"0978","addressCountry":"NO"},"telephone":"+47 23 88 89 62"},{"@type":"Place","name":"SCN R\u00f8dekro","address":{"@type":"PostalAddress","streetAddress":"H\u00e6rvejen 8","addressLocality":"R\u00f8dekro","postalCode":"6230","addressCountry":"DK"},"telephone":"+45 78 74 65 00"},{"@type":"Place","name":"SCN Madrid","address":{"@type":"PostalAddress","streetAddress":"Paseo de la Castellana, 200","addressLocality":"Madrid","postalCode":"28046","addressCountry":"ES","addressRegion":"Comunidad de Madrid"},"telephone":"+34 93 641 59 97"},{"@type":"Place","name":"SCN Tarnowskie G\u00f3ry","address":{"@type":"PostalAddress","streetAddress":"ul. Ma\u0142a 1B","addressLocality":"Tarnowskie G\u00f3ry","postalCode":"42-605","addressCountry":"PL"},"telephone":"+48 511 199 460"}],"email":"sales@scn.eu","areaServed":["SE","NO","DK","FI","EE","GB","PL","ES"],"knowsLanguage":["en","sv","da","fi","nb","et","pl","es"]}]}},"_links":{"self":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide\/8234570","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide"}],"about":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/types\/scn_guide"}],"author":[{"embeddable":true,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/users\/11"}],"version-history":[{"count":1,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide\/8234570\/revisions"}],"predecessor-version":[{"id":8235125,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/scn_guide\/8234570\/revisions\/8235125"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/media\/8234277"}],"wp:attachment":[{"href":"https:\/\/scn.eu\/da\/wp-json\/wp\/v2\/media?parent=8234570"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}